Surface Modification of Silicone for Biomedical Applications Requiring Long-Term Antibacterial, Antifouling, and Hemocompatible Properties

被引:142
作者
Li, Min [1 ]
Neoh, Koon Gee [1 ]
Xu, Li Qun [1 ]
Wang, Rong [1 ]
Kang, En-Tang [1 ]
Lau, Titus [2 ]
Olszyna, Dariusz Piotr [2 ]
Chiong, Edmund [2 ]
机构
[1] Natl Univ Singapore, Dept Chem & Biomol Engn, Singapore 117576, Singapore
[2] Natl Univ Singapore Hosp, Singapore 117576, Singapore
关键词
PERITONEAL-DIALYSIS CATHETER; CROSS-LINKED NETWORKS; POLY(ETHYLENE GLYCOL); STAPHYLOCOCCUS-AUREUS; BLOCK-COPOLYMERS; HYDROPHOBIC RECOVERY; BLOOD COMPATIBILITY; BIOFILM FORMATION; POLYMER SURFACES; IN-VITRO;
D O I
10.1021/la303438t
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Silicone has been used for peritoneal dialysis (PD) catheters for several decades. However, bacteria, platelets, proteins, and other biomolecules tend to adhere to its hydrophobic surface, which may lead to PD outflow failure, serious infection, or even death. In this work, a cross-linked poly(poly(ethylene glycol) dimethacrylate) (P(PEGDMA)) polymer layer was covalently grafted on medical-grade silicone surface to improve its antibacterial and antifouling properties. The P(PEGDMA)-grafted silicone (Silicone-g-P(PEGDMA)) substrate reduced the adhesion of Staphylococcus aureus, Escherichia coli, and Staphylococcus epidermidis, as well as 3T3 fibroblast cells by >= 90%. The antibacterial and antifouling properties were preserved after the modified substrate was aged for 30 days in phosphate buffer saline. Further immobilization of a polysulfobetaine polymer, poly((2-(methacryloyloxy)ethyl)dimethyl-(3-sulfopropyl)ammonium hydroxide) (P(DMAPS)), on the Silicone-g-P(PEGDMA) substrate via thiol-ene click reaction leads to enhanced antifouling efficacy and improved hemocompatibility with the preservation of the antibacterial property. Compared to pristine silicone, the so-obtained Silicone-g-P(PEGDMA)-P(DMAPS) substrate reduced the absorption of bovine serum albumin and bovine plasma fibrinogen by >= 80%. It also reduced the number of adherent platelets by >= 90% and significantly prolonged plasma recalcification time. The results indicate that surface grafting with P(PEGDMA) and P(DMAPS) can be potentially useful for the modification of silicone-based PD catheters for long-term applications.
引用
收藏
页码:16408 / 16422
页数:15
相关论文
共 70 条
[1]   In vitro hemocompatibility testing of UV-modified hyaluronan hydrogels [J].
Amarnath, LP ;
Srinivas, A ;
Ramamurthi, A .
BIOMATERIALS, 2006, 27 (08) :1416-1424
[2]   Prevention of Staphylococcus aureus biofilm on dialysis catheters and adherence to human cells [J].
Balaban, N ;
Gov, Y ;
Bitler, A ;
Boelaert, JR .
KIDNEY INTERNATIONAL, 2003, 63 (01) :340-345
[3]   Antifouling Coatings: Recent Developments in the Design of Surfaces That Prevent Fouling by Proteins, Bacteria, and Marine Organisms [J].
Banerjee, Indrani ;
Pangule, Ravindra C. ;
Kane, Ravi S. .
ADVANCED MATERIALS, 2011, 23 (06) :690-718
[4]   Antibiofouling Hybrid Dendritic Boltorn/Star PEG Thiol-ene Cross-Linked Networks [J].
Bartels, Jeremy W. ;
Imbesi, Philip M. ;
Finlay, John A. ;
Fidge, Christopher ;
Ma, Jun ;
Seppala, Jonathan E. ;
Nystrom, Andreas M. ;
Mackay, Michael E. ;
Callow, James A. ;
Callow, Maureen E. ;
Wooley, Karen L. .
ACS APPLIED MATERIALS & INTERFACES, 2011, 3 (06) :2118-2129
[5]   Prevention of infectious complications in peritoneal dialysis: best demonstrated practices [J].
Bender, F. H. ;
Bernardini, J. ;
Piraino, B. .
KIDNEY INTERNATIONAL, 2006, 70 :S44-S54
[6]   Polyurethanes with amphiphilic surfaces made using telechelic functional PDMS having orthogonal acid functional groups [J].
Bodkhe, Rajan B. ;
Stafslien, Shane J. ;
Cilz, Nicholas ;
Daniels, Justin ;
Thompson, Stephanie E. M. ;
Callow, Maureen E. ;
Callow, James A. ;
Webster, Dean C. .
PROGRESS IN ORGANIC COATINGS, 2012, 75 (1-2) :38-48
[7]   Reduced acute inflammatory responses to microgel conformal coatings [J].
Bridges, Amanda W. ;
Singh, Neetu ;
Burns, Kellie L. ;
Babensee, Julia E. ;
Lyon, L. Andrew ;
Garcia, Andres J. .
BIOMATERIALS, 2008, 29 (35) :4605-4615
[8]  
Buck ME, 2012, POLYM CHEM-UK, V3, P66, DOI [10.1039/c1py00314c, 10.1039/C1PY00314C]
[9]   Enhancing blood compatibility of biodegradable polymers by introducing sulfobetaine [J].
Cao, Jun ;
Chen, Yuan-Wei ;
Wang, Xin ;
Luo, Xiang-Lin .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2011, 97A (04) :472-479
[10]   Engineering the Polymer Backbone To Strengthen Nonfouling Sulfobetaine Hydrogels [J].
Carr, Louisa ;
Cheng, Gang ;
Xue, Hong ;
Jiang, Shaoyi .
LANGMUIR, 2010, 26 (18) :14793-14798