Localization of gaps during redo ablations of paroxysmal atrial fibrillation: Preferential patterns depending on the choice of cryoballoon ablation or radiofrequency ablation for the initial procedure

被引:13
|
作者
Galand, Vincent [1 ,2 ,3 ]
Pavin, Dominique [1 ,2 ,3 ]
Behar, Nathalie [1 ,2 ,3 ]
Auffret, Vincent [1 ,2 ,3 ]
Feneon, Damien [1 ,2 ,3 ]
Behaghel, Albin [1 ,2 ,3 ]
Daubert, Jean-Claude [1 ,2 ,3 ]
Mabo, Philippe [1 ,2 ,3 ]
Martins, Raphael P. [1 ,2 ,3 ]
机构
[1] CHU Rennes, Serv Cardiol & Malad Vasc, 2 Rue Henri Le Guilloux, F-35000 Rennes, France
[2] Univ Rennes 1, CIC IT 1414, F-35000 Rennes, France
[3] INSERM, U1099, F-35000 Rennes, France
关键词
Atrial fibrillation; Ablation; Cryoballoon ablation; Radiofrequency; Redo; PULMONARY VEIN ISOLATION; CATHETER ABLATION; CONDUCTION RECOVERY; EFFICACY; SAFETY;
D O I
10.1016/j.acvd.2016.03.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Pulmonary vein (PV) isolation, using cryoballoon or radiofrequency ablation, is the cornerstone therapy for symptomatic paroxysmal atrial fibrillation (AF) refractory to antiarrhythmic drugs. One-third of the patients have recurrences, mainly due to PV reconnections. Aims. - To describe the different locations of reconnection sites in patients who had previously undergone radiofrequency or cryoballoon ablation, and to compare the characteristics of the redo procedures in both instances. Methods. - Demographic data and characteristics of the initial ablation (cryoballoon or radiofrequency) were collected. Number and localization of reconduction gaps, and redo characteristics were reviewed. Results. - Seventy-four patients scheduled for a redo ablation of paroxysmal AF were included; 38 had been treated by radiofrequency ablation and 36 by cryoballoon ablation during the first procedure. For the initial ablation, procedural and fluoroscopy times were significantly shorter for cryoballoon ablation (147.8 +/- 52.6 min vs. 226.6 +/- 64.3 min [P<0.001] and 37.0 +/- 17.7 min vs. 50.8 +/- 22.7 min [P=0.005], respectively). Overall, an identical number of gaps was found during redo procedures of cryoballoon and radiofrequency ablations. However, a significantly higher number of gaps were located in the right superior PV for patients first ablated with radiofrequency (0.9 +/- 1.0 vs. 0.5 +/- 0.9; P=0.009). Gap localization displayed different patterns. Although not significant, redo procedures of cryoballoon ablation were slightly shorter and needed shorter durations of radiofrequency to achieve PV isolation. Conclusions. - During redo procedures, gap localization pattern is different for patients first ablated with cryoballoon or radiofrequency ablation, and right superior PV reconnections occur more frequently after radiofrequency ablation. Redo ablation of a previous cryoballoon ablation appears to be easier. (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 50 条
  • [21] A Comparative Analysis of Radiofrequency Ablation with Contact Force Sensing and Second-Generation Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: A Study at the Najaf Cardiac Center
    Shekhani, Ali Hamadameen
    Talib, Ahmed Abdulkarim
    Mustafa, Muhammad Kareem
    MEDICINA BALEAR, 2024, 39 (04):
  • [22] A novel catheter ablation strategy for non-paroxysmal atrial fibrillation combining cryoballoon, radiofrequency, and Marshall-vein ethanol ablations
    Hayasaka, Kazuto
    Sasaki, Takeshi
    Shirai, Yasuhiro
    Shimosato, Hikaru
    Tahara, Tomohiro
    Segami, Shota
    Nagasawa, Ryo
    Akimoto, Ko
    Yabe, Kento
    Toya, Chisashi
    Watanabe, Keita
    Yamashita, Shu
    Suzuki, Masahito
    Sugiyama, Koji
    Yamauchi, Yasuteru
    Okishige, Kaoru
    Goya, Masahiko
    Sasano, Tetsuo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (06): : 475 - 486
  • [23] Cryoballoon vs. radiofrequency contact force ablation for paroxysmal atrial fibrillation: a propensity score analysis
    Matta, Mario
    Anselmino, Matteo
    Ferraris, Federico
    Scaglione, Marco
    Gaita, Fiorenzo
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 (04) : 141 - 147
  • [24] Safety, efficacy, and cost–performance of a simplified cryoballoon ablation procedure for paroxysmal atrial fibrillation
    Yasuhiro Matsuda
    Masaharu Masuda
    Takashige Sakio
    Mitsutoshi Asai
    Osamu Iida
    Shin Okamoto
    Takayuki Ishihara
    Kiyonori Nanto
    Takashi Kanda
    Takuya Tsujimura
    Yosuke Hata
    Hiroyuki Uematsu
    Toshiaki Mano
    Journal of Interventional Cardiac Electrophysiology, 2022, 64 : 427 - 435
  • [25] Catheter ablation for paroxysmal atrial fibrillation: new generation cryoballoon or contact force sensing radiofrequency ablation?
    Nagy Zsofia
    Kis Zsuzsanna
    Som Zoltan
    Foldesi Csaba
    Kardos Attila
    ORVOSI HETILAP, 2016, 157 (22) : 849 - 854
  • [26] Cryoballoon ablation as index procedure for paroxysmal atrial fibrillation: long-term results from a single center early experience
    Rao, Jayakeerthi Yoganarasimha
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    Casado-Arroyo, Ruben
    Overeinder, Ingrid
    Sarkozy, Andrea
    Paparella, Gaetano
    Capulzini, Lucio
    Sorgente, Antonio
    Rodriguez-Manero, Moises
    Ricciardi, Danilo
    Namdar, Mehdi
    Brugada, Pedro
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2014, 15 (03) : 194 - 198
  • [27] Results from a multicentre comparison of cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: is cryoablation more reproducible?
    Providencia, Rui
    Defaye, Pascal
    Lambiase, Pier D.
    Pavin, Dominique
    Cebron, Jean-Pierre
    Halimi, Franck
    Anselme, Frederic
    Srinivasan, Neil
    Albenque, Jean-Paul
    Boveda, Serge
    EUROPACE, 2017, 19 (01): : 48 - 57
  • [28] Cryoballoon vs. radiofrequency ablation for paroxysmal atrial fibrillation: an updated meta-analysis of randomized and observational studies
    Buiatti, Alessandra
    von Olshausen, Gesa
    Barthel, Petra
    Schneider, Simon
    Luik, Armin
    Kaess, Bernhard
    Laugwitz, Karl-Ludwig
    Hoppmann, Petra
    EUROPACE, 2017, 19 (03): : 378 - 384
  • [29] Cryoballoon vs. open irrigated radiofrequency ablation for paroxysmal atrial fibrillation: long-term FreezeAF outcomes
    Luik, Armin
    Kunzmann, Kevin
    Hormann, Patrick
    Schmidt, Kerstin
    Radzewitz, Andrea
    Bramlage, Peter
    Schenk, Thomas
    Schymik, Gerhard
    Merkel, Matthias
    Kieser, Meinhard
    Schmitt, Claus
    BMC CARDIOVASCULAR DISORDERS, 2017, 17
  • [30] Comparison of P-wave parameter changes after radiofrequency ablation and cryoballoon ablation for paroxysmal atrial fibrillation: An observational cohort study
    Antoun, Ibrahim
    Li, Xin
    Vali, Zakkariya
    Abdelrazik, Ahmed
    Somani, Riyaz
    Ng, G. Andre
    JOURNAL OF ELECTROCARDIOLOGY, 2025, 89