Localization of gaps during redo ablations of paroxysmal atrial fibrillation: Preferential patterns depending on the choice of cryoballoon ablation or radiofrequency ablation for the initial procedure

被引:13
作者
Galand, Vincent [1 ,2 ,3 ]
Pavin, Dominique [1 ,2 ,3 ]
Behar, Nathalie [1 ,2 ,3 ]
Auffret, Vincent [1 ,2 ,3 ]
Feneon, Damien [1 ,2 ,3 ]
Behaghel, Albin [1 ,2 ,3 ]
Daubert, Jean-Claude [1 ,2 ,3 ]
Mabo, Philippe [1 ,2 ,3 ]
Martins, Raphael P. [1 ,2 ,3 ]
机构
[1] CHU Rennes, Serv Cardiol & Malad Vasc, 2 Rue Henri Le Guilloux, F-35000 Rennes, France
[2] Univ Rennes 1, CIC IT 1414, F-35000 Rennes, France
[3] INSERM, U1099, F-35000 Rennes, France
关键词
Atrial fibrillation; Ablation; Cryoballoon ablation; Radiofrequency; Redo; PULMONARY VEIN ISOLATION; CATHETER ABLATION; CONDUCTION RECOVERY; EFFICACY; SAFETY;
D O I
10.1016/j.acvd.2016.03.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Pulmonary vein (PV) isolation, using cryoballoon or radiofrequency ablation, is the cornerstone therapy for symptomatic paroxysmal atrial fibrillation (AF) refractory to antiarrhythmic drugs. One-third of the patients have recurrences, mainly due to PV reconnections. Aims. - To describe the different locations of reconnection sites in patients who had previously undergone radiofrequency or cryoballoon ablation, and to compare the characteristics of the redo procedures in both instances. Methods. - Demographic data and characteristics of the initial ablation (cryoballoon or radiofrequency) were collected. Number and localization of reconduction gaps, and redo characteristics were reviewed. Results. - Seventy-four patients scheduled for a redo ablation of paroxysmal AF were included; 38 had been treated by radiofrequency ablation and 36 by cryoballoon ablation during the first procedure. For the initial ablation, procedural and fluoroscopy times were significantly shorter for cryoballoon ablation (147.8 +/- 52.6 min vs. 226.6 +/- 64.3 min [P<0.001] and 37.0 +/- 17.7 min vs. 50.8 +/- 22.7 min [P=0.005], respectively). Overall, an identical number of gaps was found during redo procedures of cryoballoon and radiofrequency ablations. However, a significantly higher number of gaps were located in the right superior PV for patients first ablated with radiofrequency (0.9 +/- 1.0 vs. 0.5 +/- 0.9; P=0.009). Gap localization displayed different patterns. Although not significant, redo procedures of cryoballoon ablation were slightly shorter and needed shorter durations of radiofrequency to achieve PV isolation. Conclusions. - During redo procedures, gap localization pattern is different for patients first ablated with cryoballoon or radiofrequency ablation, and right superior PV reconnections occur more frequently after radiofrequency ablation. Redo ablation of a previous cryoballoon ablation appears to be easier. (C) 2016 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:591 / 598
页数:8
相关论文
共 15 条
[1]   Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies [J].
Andrade, Jason G. ;
Khairy, Paul ;
Guerra, Peter G. ;
Deyell, Marc W. ;
Rivard, Lena ;
Macle, Laurent ;
Thibault, Bernard ;
Talajic, Mario ;
Roy, Denis ;
Dubuc, Marc .
HEART RHYTHM, 2011, 8 (09) :1444-1451
[2]   Morphological evidence of muscular connections between contiguous pulmonary venous orifices: Relevance of the interpulmonary isthmus for catheter ablation in atrial fibrillation [J].
Cabrera, Jose Angel ;
Ho, Siew Yen ;
Climent, Vicente ;
Fuertes, Beatriz ;
Murillo, Margarita ;
Sanchez-Quintana, Damian .
HEART RHYTHM, 2009, 6 (08) :1192-1198
[3]   Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation [J].
Cappato, Riccardo ;
Calkins, Hugh ;
Chen, Shih-Ann ;
Davies, Wyn ;
Iesaka, Yoshito ;
Kalman, Jonathan ;
Kim, You-Ho ;
Klein, George ;
Natale, Andrea ;
Packer, Douglas ;
Skanes, Allan ;
Ambrogi, Federico ;
Biganzoli, Elia .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (01) :32-38
[4]   The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study [J].
Chun, Kyoung-Ryul Julian ;
Schmidt, Boris ;
Metzner, Andreas ;
Tilz, Roland ;
Zerm, Thomas ;
Koester, Ilka ;
Fuernkranz, Alexander ;
Koektuerk, Buelent ;
Konstantinidou, Melanie ;
Antz, Matthias ;
Ouyang, Feifan ;
Kuck, Karl Heinz .
EUROPEAN HEART JOURNAL, 2009, 30 (06) :699-709
[5]   Characterization of conduction recovery after pulmonary vein isolation using the "single big cryoballoon" technique [J].
Fuernkranz, Alexander ;
Chun, K. R. Julian ;
Nuyens, Dieter ;
Metzner, Andreas ;
Koester, Ilka ;
Schmidt, Boris ;
Ouyang, Feifan ;
Kuck, Karl-Heinz .
HEART RHYTHM, 2010, 7 (02) :184-190
[6]   Lessons From Radiofrequency Redo-Procedure After Cryoballoon Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation [J].
Godin, Benedicte ;
Savoure, Arnaud ;
Gardey, Kevin ;
Anselme, Frederic .
CIRCULATION JOURNAL, 2013, 77 (08) :2009-2013
[7]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[8]   Relationship Between Contact Force Sensing Technology and Medium-Term Outcome of Atrial Fibrillation Ablation: A Multicenter Study of 600 Patients [J].
Jarman, Julian W. E. ;
Panikker, Sandeep ;
Das, Moloy ;
Wynn, Gareth J. ;
Ullah, Waqas ;
Kontogeorgis, Andrianos ;
Haldar, Shouvik K. ;
Patel, Preya J. ;
Hussain, Wajid ;
Markides, Vias ;
Gupta, Dhiraj ;
Schilling, Richard J. ;
Wong, Tom .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (04) :378-384
[9]   Incidence of pulmonary vein conduction recovery in patients without clinical recurrence after ablation of paroxysmal atrial fibrillation: Mechanistic implications [J].
Jiang, Ru-hong ;
Po, Sunny S. ;
Tung, Roderick ;
Liu, Qiang ;
Sheng, Xia ;
Zhang, Zu-wen ;
Sun, Ya-xun ;
Yu, Lu ;
Zhang, Pei ;
Fu, Guo-sheng ;
Jiang, Chen-yang .
HEART RHYTHM, 2014, 11 (06) :969-976
[10]   Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation [J].
Martins, Raphael P. ;
Hamon, David ;
Cesari, Olivier ;
Behaghel, Albin ;
Behar, Nathalie ;
Sellal, Jean-Marc ;
Daubert, Jean-Claude ;
Mabo, Philippe ;
Pavin, Dominique .
HEART RHYTHM, 2014, 11 (03) :386-393