Robust motion correction for respiratory gated PET/CT using weighted averaging
被引:0
作者:
Thielemans, Kris
论文数: 0引用数: 0
h-index: 0
机构:
Hammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, EnglandHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Thielemans, Kris
[1
]
Gopalakrishnan, Girish
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Bangalore, Karnataka, IndiaHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Gopalakrishnan, Girish
[2
]
Roy, Arunabha
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Bangalore, Karnataka, IndiaHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Roy, Arunabha
[2
]
Srikrishnan, V
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Bangalore, Karnataka, IndiaHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Srikrishnan, V
[2
]
Thiruvenkadam, Sheshadri
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Bangalore, Karnataka, IndiaHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Thiruvenkadam, Sheshadri
[2
]
Wollenweber, Scott D.
论文数: 0引用数: 0
h-index: 0
机构:
GE Healthcare, Waukesha, WI 53188 USAHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Wollenweber, Scott D.
[3
]
Manjeshwar, Ravindra M.
论文数: 0引用数: 0
h-index: 0
机构:
GE Global Res, Niskayuna, NY 12309 USAHammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
Manjeshwar, Ravindra M.
[4
]
机构:
[1] Hammersmith Hosp, Hammersmith Imanet Ltd, GE Healthcare, Du Cane Rd, London W12 0NN, England
[2] GE Global Res, Bangalore, Karnataka, India
[3] GE Healthcare, Waukesha, WI 53188 USA
[4] GE Global Res, Niskayuna, NY 12309 USA
来源:
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC)
|
2011年
关键词:
POSITRON-EMISSION-TOMOGRAPHY;
ARTIFACTS;
D O I:
暂无
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
Movement degrades image quality in PET/CT. A common strategy is to gate the PET data, reconstruct the images, register each image to a reference gate, and average the registered images (Reconstruct, Registered, Average or RRA). Previously, we have shown that this technique can provide more quantitatively accurate PET images compared to the ungated case, while using all the data means that RRA images have better counting statistics than single gates. However, in some instances, e. g. large patient motion, low count statistics acquisitions and/or mismatch between PET and CT position, the registration might fail for a particular gate in some region of the image, resulting in artifacts in the final motion corrected image. We have developed techniques to automatically detect such failures for every image voxel based on an analysis of the motion vectors and the image values. We propose to use a weighted average, where the weights are gate and voxel dependent, and are determined based on estimated registration quality. We illustrate this idea using respiratory gated PET data with PET-PET registration using the level-sets non-rigid registration algorithm. We applied this technique to respiratory gated phantom and patient data from GE Discovery PET/CT scanners. The results demonstrate that the method reliably mitigates any image artifacts and is robust to large lesion displacements and low count density PET images.