Improved thermal stability of antimony-doped amorphous selenium film for X-ray flat-panel detectors

被引:6
|
作者
Chen, Zexiang [1 ]
Dong, Miao [1 ]
Li, Chun [1 ]
Shao, Shengzi [1 ]
Hu, Tianyong [1 ]
Kang, Dequn [1 ]
机构
[1] Univ Elect Sci & Technol China, Sch Optoelect Informat, Chengdu 610054, Peoples R China
来源
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE | 2013年 / 210卷 / 03期
基金
美国国家科学基金会;
关键词
amorphous selenium; doping; X-ray detectors; CHEST RADIOGRAPHY; IMAGE SENSORS; A-SE; ALLOYS; PHOTOCONDUCTORS; MAMMOGRAPHY; PERFORMANCE; SYSTEM;
D O I
10.1002/pssa.201228432
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Amorphous selenium (a-Se) film is a promising photoconductive material for X-ray flat-panel detectors (FPD) application. However, a-Se tends to be crystalline Se at near room temperature. This remarkable temperature sensitivity limits its practical application. To prevent the near-room-temperature crystallization of a-Se film, we fabricate antimony (Sb)-doped a-Se films using a vacuum evaporation technique equipped with an in situ cooling trap. We experimentally demonstrate that the Sb doping improves the thermal stability of a-Se film while possessing a similar X-ray photoelectric conversion efficiency as the pure a-Se film. After air annealing at 50 degrees C for 90min, the X-ray diffraction (XRD) results of the 4.1at.% Sb-doped a-Se film shows no detectable crystallization diffraction peak. Upon applying an electric field of 10V mu m1, such Sb-doped a-Se film exhibits dark current density below 1nAcm2, while under an X-ray dosage of about 4mGy, the annealed Sb-doped a-Se film shows a photocurrent density of more than 100nAcm2.
引用
收藏
页码:580 / 584
页数:5
相关论文
共 50 条
  • [31] Comparison of amorphous selenium and mercuric iodide film for diagnostic X-ray imaging
    Park, Ji-Koon
    Kang, Sang-Sik
    Cho, Sung-Ho
    Kim, So-Yeong
    Son, Dae-Woong
    Shin, Jung-Wook
    Choi, Jang-Yong
    Chun, Byung-Kyu
    Nam, Sang-Hee
    ADVANCES IN NANOMATERIALS AND PROCESSING, PTS 1 AND 2, 2007, 124-126 : 507 - +
  • [32] Radiation exposure in full-field digital mammography with a flat-panel x-ray detector based on amorphous silicon in comparison with conventional screen-film mammography.
    Hermann, KP
    Obenauer, S
    Grabbe, E
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (11): : 940 - 945
  • [33] Rheological engineering of perovskite suspension toward high-resolution X-ray flat-panel detector
    Song, Zihao
    Du, Xinyuan
    He, Xin
    Wang, Hanqi
    Liu, Zhiqiang
    Wu, Haodi
    Luo, Hongde
    Jin, Libo
    Xu, Ling
    Zheng, Zhiping
    Niu, Guangda
    Tang, Jiang
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [34] Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors
    Kasap, Safa
    Frey, Joel B.
    Belev, George
    Tousignant, Olivier
    Mani, Habib
    Greenspan, Jonathan
    Laperriere, Luc
    Bubon, Oleksandr
    Reznik, Alla
    DeCrescenzo, Giovanni
    Karim, Karim S.
    Rowlands, John A.
    SENSORS, 2011, 11 (05) : 5112 - 5157
  • [35] Dual-exposure technique for extending the dynamic range of x-ray flat panel detectors
    Sisniega, A.
    Abella, M.
    Desco, M.
    Vaquero, J. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (02) : 421 - 439
  • [36] Columnar recombination for X-ray generated electron-holes in amorphous selenium and its significance in a-Se x-ray detectors
    Bubon, O.
    Jandieri, K.
    Baranovskii, S. D.
    Kasap, S. O.
    Reznik, A.
    JOURNAL OF APPLIED PHYSICS, 2016, 119 (12)
  • [37] The dependence of the modulation transfer function on the blocking layer thickness in amorphous selenium x-ray detectors
    Hunter, David M.
    Belev, Gueorgi
    DeCrescenzo, Giovanni
    Kasap, Safa O.
    Mainprize, James G.
    Rowlands, J. A.
    Smith, Charles
    Tuemer, Tuemay
    Verpakhovski, Vladimir
    Yin, Shi
    Yaffe, Martin J.
    MEDICAL PHYSICS, 2007, 34 (08) : 3358 - 3373
  • [38] The fabrication and characterization of direct conversion flat panel X-ray imager with TlBr film
    Hamdan, Moh
    Shimazoe, Kenji
    Takahashi, Hiroyuki
    Nogami, Mitsuhiro
    Hitomi, Keitaro
    Asakura, Shinya
    Tsunashima, Takanori
    Nakamura, Takashi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [39] Noise properties of a Se-based flat-panel X-ray detector with CMOS readout integrated circuits
    Adachi, S
    Hirasawa, S
    Takahashi, M
    Okada, H
    Yamane, Y
    Yamada, S
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 580 - 591
  • [40] Dark current mechanisms in stabilized amorphous selenium based n-i detectors for x-ray imaging applications
    Mahmood, S. A.
    Kabir, M. Z.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2011, 29 (03):