DBCG hypo trial validation of radiotherapy parameters from a national data bank versus manual reporting

被引:21
作者
Brink, Carsten [1 ]
Lorenzen, Ebbe L. [2 ]
Krogh, Simon Long [2 ]
Westberg, Jonas [2 ]
Berg, Martin [3 ]
Jensen, Ingelise [4 ]
Thomsen, Mette Skovhus [5 ]
Yates, Esben Svitzer [5 ]
Offersen, Birgitte Vrou [6 ,7 ]
机构
[1] Univ Southern Denmark, Inst Clin Res, Odense, Denmark
[2] Odense Univ Hosp, Lab Radiat Phys, Odense, Denmark
[3] Vejle Hosp, Dept Med Phys, Vejle, Denmark
[4] Aalborg Univ Hosp, Dept Med Phys, Aalborg, Denmark
[5] Aarhus Univ Hosp, Dept Med Phys, Aarhus, Denmark
[6] Aarhus Univ, Inst Clin Med, Aarhus, Denmark
[7] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
关键词
LOCALLY ADVANCED NSCLC; RADIATION ONCOLOGY; DESIGN;
D O I
10.1080/0284186X.2017.1406140
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The current study evaluates the data quality achievable using a national data bank for reporting radiotherapy parameters relative to the classical manual reporting method of selected parameters. Methods: The data comparison is based on 1522 Danish patients of the DBCG hypo trial with data stored in the Danish national radiotherapy data bank. In line with standard DBCG trial practice selected parameters were also reported manually to the DBCG database. Categorical variables are compared using contingency tables, and comparison of continuous parameters is presented in scatter plots. Results: For categorical variables 25 differences between the data bank and manual values were located. Of these 23 were related to mistakes in the manual reported value whilst the remaining two were a wrong classification in the data bank. The wrong classification in the data bank was related to lack of dose information, since the two patients had been treated with an electron boost based on a manual calculation, thus data was not exported to the data bank, and this was not detected prior to comparison with the manual data. For a few database fields in the manual data an ambiguity of the parameter definition of the specific field is seen in the data. This was not the case for the data bank, which extract all data consistently. Conclusions: In terms of data quality the data bank is superior to manually reported values. However, there is a need to allocate resources for checking the validity of the available data as well as ensuring that all relevant data is present. The data bank contains more detailed information, and thus facilitates research related to the actual dose distribution in the patients.
引用
收藏
页码:107 / 112
页数:6
相关论文
共 21 条
[1]  
[Anonymous], 2010, J ICRU, DOI [10.1093/jicru_ndq002, DOI 10.1093/JICRU_NDQ002]
[2]   How Significant Is A Boxplot Outlier? [J].
Dawson, Robert .
JOURNAL OF STATISTICS EDUCATION, 2011, 19 (02)
[3]   Guidelines for treatment naming in radiation oncology [J].
Denton, Travis R. ;
Shields, Lisa B. E. ;
Hahl, Michael ;
Maudlin, Casey ;
Bassett, Mark ;
Spalding, Aaron C. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02) :123-138
[4]   EORTC Radiation Oncology Group quality assurance platform: Establishment of a digital central review facility [J].
Fairchild, Alysa ;
Aird, Edwin ;
Fenton, Paul A. ;
Gregoire, Vincent ;
Gulyban, Akos ;
Lacombe, Denis ;
Matzinger, Oscar ;
Poortmans, Philip ;
Ruyskart, Pascal ;
Weber, Damien C. ;
Hurkmans, Coen W. .
RADIOTHERAPY AND ONCOLOGY, 2012, 103 (03) :279-286
[5]   A randomized phase II trial of concurrent chemoradiation with two doses of radiotherapy, 60 Gy and 66 Gy, concomitant with a fixed dose of oral vinorelbine in locally advanced NSCLC [J].
Hansen, Olfred ;
Knap, Marianne M. ;
Khalil, Azza ;
Nyhus, Christa H. ;
McCulloch, Tine ;
Holm, Bente ;
Brink, Carsten ;
Hoffmann, Lone ;
Schytte, Tine .
RADIOTHERAPY AND ONCOLOGY, 2017, 123 (02) :276-281
[6]   DICOM Metadata repository for technical information in digital medical images [J].
Kallman, Hans-Erik ;
Halsius, Erik ;
Olsson, Magnus ;
Stenstrom, Mats .
ACTA ONCOLOGICA, 2009, 48 (02) :285-288
[7]   Developing a Multi-Institutional PACS Archive and Designing Processes to Manage the Shift from a Film to a Digital-Based Archive [J].
Laprise, Nicole K. ;
Hanusik, Richard ;
FitzGerald, T. J. ;
Rosen, Nancy ;
White, Keith S. .
JOURNAL OF DIGITAL IMAGING, 2009, 22 (01) :15-24
[8]   Groupwise Conditional Random Forests for Automatic Shape Classification and Contour Quality Assessment in Radiotherapy Planning [J].
McIntosh, Chris ;
Svistoun, Igor ;
Purdie, Thomas G. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (06) :1043-1057
[9]   Heterogeneous FDG-guided dose-escalation for locally advanced NSCLC (the NARLAL2 trial): Design and early dosimetric results of a randomized, multi-centre phase-III study [J].
Moller, Ditte Sloth ;
Nielsen, Tine Bjorn ;
Brink, Carsten ;
Hoffmann, Lone ;
Lutz, Christina Maria ;
Lund, Mikkel Drogemuller ;
Hansen, Olfred ;
Schytte, Tine ;
Khalil, Azza Ahmed ;
Knap, Marianne Marquard ;
Nyhus, Christa Haugaard ;
Ottosson, Wiviann ;
Sibolt, Patrik ;
Borissova, Svetlana ;
Josipovic, Mirjana ;
Persson, Gitte ;
Appelt, Ane Lindegaard .
RADIOTHERAPY AND ONCOLOGY, 2017, 124 (02) :311-317
[10]  
Mouridsen H, 2017, ACTA ONCOL UNPUB