A Theoretical Comparative Study of CO2 Cascade Refrigeration Systems

被引:41
作者
Bellos, Evangelos [1 ]
Tzivanidis, Christos [1 ]
机构
[1] Natl Tech Univ Athens, Sch Mech Engn, Thermal Dept, Athens 15780, Greece
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 04期
关键词
CO2; refrigerant; cascade; total equivalent warming impact; refrigerant comparison; yearly COP; ADVANCED EXERGY ANALYSIS; SUPERMARKET REFRIGERATION; THERMODYNAMIC ANALYSIS; PERFORMANCE; ENERGY; COMPRESSION; EJECTOR; CYCLE; OPTIMIZATION; WORKING;
D O I
10.3390/app9040790
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The objective of this work is the comparison of the different cascade refrigeration systems with CO2 in the low-temperature circuit. A total of 18 different cascade refrigeration systems are examined including the CO2/CO2 cascade system. The analysis is performed for four different evaporator temperatures (-35, -25, -15 and -5 degrees C), while the condenser temperature is ranged from 10 up to 45 degrees C. The systems are compared energetically, as well as using the total equivalent warming impact (TEWI) for yearly operation at the weather conditions of Athens (Greece). The final results show that all the examined cascade systems are more efficient than the CO2/CO2 cascade system. The natural refrigerants (NH3, R290, R600, R600a and R1270) seem to be the most appropriate choices according to the energy and the TEWI criteria. Moreover, the refrigerant R152a is a promising choice for achieving high performance with a relatively low TEWI.
引用
收藏
页数:19
相关论文
共 46 条
[1]   Natural and synthetic refrigerants, global warming: A review [J].
Abas, Naeem ;
Kalair, Ali Raza ;
Khan, Nasrullah ;
Haider, Aun ;
Saleem, Zahid ;
Saleem, Muhammad Shoaib .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 90 :557-569
[2]  
AIRAH, 2012, Methods of calculating total equivalent warming impact (TEWI) 2012
[3]  
[Anonymous], 2015, Engineering Equation Solver
[4]   Investigation of the Environmentally-Friendly Refrigerant R152a for Air Conditioning Purposes [J].
Bellos, Evangelos ;
Tzivanidis, Christos .
APPLIED SCIENCES-BASEL, 2019, 9 (01)
[5]   A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants [J].
Beshr, M. ;
Aute, V. ;
Sharma, V. ;
Abdelaziz, O. ;
Fricke, B. ;
Radermacher, R. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 56 :154-164
[6]   Exergy maximization of cascade refrigeration cycles and its numerical verification for a transcritical CO2-C3H8 system [J].
Bhattacharyya, Souvik ;
Bose, S. ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04) :624-632
[7]   Thermodynamic analysis and optimization of a novel N2O-CO2 cascade system for refrigeration and heating [J].
Bhattacharyya, Souvik ;
Garai, Anirban ;
Sarkar, Jahar .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05) :1077-1084
[8]  
Brown JS, 2002, INT J REFRIG, V25, P19
[9]   Design and simulation of a heat pump for simultaneous heating and cooling using HFC or CO2 as a working fluid [J].
Byrne, Paul ;
Miriel, Jacques ;
Lenat, Yves .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (07) :1711-1723
[10]   Energy evaluation of R152a as drop in replacement for R134a in cascade refrigeration plants [J].
Cabello, R. ;
Sanchez, D. ;
Llopis, R. ;
Catalan, J. ;
Nebot-Andres, L. ;
Torrella, E. .
APPLIED THERMAL ENGINEERING, 2017, 110 :972-984