Inter-rater variability in reporting enhancing lesions present on standard and triple dose gadolinium scans of patients with multiple sclerosis

被引:14
作者
Filippi, M
Barkhof, F
Bressi, S
Yousry, TA
Miller, DH
机构
[1] FREE UNIV AMSTERDAM HOSP, DEPT DIAGNOST RADIOL, MR CTR MS RES, NL-1007 MB AMSTERDAM, NETHERLANDS
[2] UNIV MUNICH, KLINIKUM GROSSHADERN, DEPT DIAGNOST RADIOL, D-8000 MUNICH, GERMANY
[3] UNIV LONDON, NEUROL INST, NMR RES UNIT, LONDON, ENGLAND
关键词
multiple sclerosis; magnetic resonance imaging; enhancing lesions; triple dose of gadolinium; inter-observer variability;
D O I
10.1177/135245859700300402
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In this study we evaluated and compared the inter-rater variabilities in detecting enhancing lesions in patients with MS after injection of a standard dose (s.d) and a triple dose (TD) of gadolinium (Gd). Enhanced magnetic resonance imaging (MRI) were obtained in 15 patients, consisting of T-1-weighted images 5 to 7 min after the injection of the sdd (0.1 mmol/kg) of Gd end, after on interval of 6 to 24 h, 5 to 7 min after the injection of the TD (0.3 mmol/kg). An additional scan 1 h after the TD injection (delayed scanning -DS) was obtained in 11 patients. The scans were independently evaluated in a random order by four observers. Lesions were counted and scored according to size and location. The level of interobserver concordance was very high for reporting the total numbers of enhancing lesions, their sizes and sites for the three experimental conditions. No significant differences were found in inter-observer variability in reporting the total number of enhancing lesions and their location in different brain sites in the three conditions. Our data indicate that the gain in sensitivity in detecting enhancing lesions in MS with the TD is not counteracted by a loss in reproducibility. This is important in planning clinical trials in which the number of enhancing lesions is used as a measure of outcome.
引用
收藏
页码:226 / 230
页数:5
相关论文
共 18 条
[1]   ROBUST TESTS FOR EQUALITY OF VARIANCES [J].
BROWN, MB ;
FORSYTHE, AB .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1974, 69 (346) :364-367
[2]   A high resolution three dimensional T-1-weighted gradient echo sequence improves the detection of disease activity in multiple sclerosis [J].
Filippi, M ;
Yousry, T ;
Horsfield, MA ;
Alkadhi, H ;
Rovaris, M ;
Campi, A ;
Voltz, R ;
Comi, G .
ANNALS OF NEUROLOGY, 1996, 40 (06) :901-907
[3]   COMPARISON OF TRIPLE DOSE VERSUS STANDARD-DOSE GADOLINIUM-DTPA FOR DETECTION OF MRI ENHANCING LESIONS IN PATIENTS WITH PRIMARY PROGRESSIVE MULTIPLE-SCLEROSIS [J].
FILIPPI, M ;
CAMPI, A ;
MARTINELLI, V ;
COLOMBO, B ;
YOUSRY, T ;
CANAL, N ;
SCOTTI, G ;
COMI, G .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 59 (05) :540-544
[4]   Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS [J].
Filippi, M ;
Yousry, T ;
Campi, A ;
Kandziora, C ;
Colombo, B ;
Voltz, R ;
Martinelli, V ;
Spuler, S ;
Bressi, S ;
Scotti, G ;
Comi, G .
NEUROLOGY, 1996, 46 (02) :379-384
[5]   Triple dose of gadolinium-DTPA and delayed MRI in patients with benign multiple sclerosis [J].
Filippi, M ;
Capra, R ;
Campi, A ;
Colombo, B ;
Prandini, F ;
Marciano, N ;
Gasparotti, R ;
Comi, G .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1996, 60 (05) :526-530
[6]  
FILIPPI M, 1996, CURR OPIN NEUROL, V9, P176
[7]  
FILIPPI M, 1997, IN PRESS ACTA NEUROL
[8]  
FINELLI DA, 1994, RADIOLOGY, V36, P62
[9]  
GUTTMANN CRG, 1995, AM J NEURORADIOL, V16, P1481
[10]   A preliminary study into the sensitivity of disease activity detection by serial weekly magnetic resonance imaging in multiple sclerosis [J].
Lai, M ;
Hodgson, T ;
GawneCain, M ;
Webb, S ;
MacManus, D ;
McDonald, WI ;
Thompson, AJ ;
Miller, DH .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1996, 60 (03) :339-341