ANALYSIS OF MITIGATION TECHNIQUES FOR BEARING CURRENTS IN PWM INVERTER DRIVES

被引:0
作者
Bjekic, Miroslav [1 ]
Stojanovic, Danilo [1 ]
Rosic, Marko [1 ]
Bozic, Milos [1 ]
机构
[1] Univ Kragujevac, Tech Fac Cacak, Kragujevac, Serbia
来源
METALURGIA INTERNATIONAL | 2013年 / 18卷 / 02期
关键词
Bearing; common-mode voltage; EDM; filter; PWM inverter; power drive;
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The purpose of this paper is to provide the reader with an introductory knowledge of the phenomenon of bearing currents, in which situations it occurs and how to mitigate the problem. This study presents different techniques and topologies of equipment for mitigation of bearing current in PWM inverter drives, available on the market. We present the techniques that can be applied to the existing drives, Many other methods which require special drive hardware or a motor solution are not discussed here. Since there are numerous industry papers available that discuss the details of problems caused by PWM VFD, this paper will focus on a more general discussion of the causes, analysis and possible solutions.
引用
收藏
页码:91 / 97
页数:7
相关论文
共 23 条
[1]  
Akagi H., 2006, IEEE T IND APPL, V21
[2]  
Bell S., 1998, IEEE T IND APPL, V5
[3]  
BINDER A, 2008, IEEE T IND APPL, V44
[4]   Bearing currents and their relationship to PWM drives [J].
Busse, D ;
Erdman, J ;
Kerkman, RJ ;
Schlegel, D ;
Skibinski, G .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (02) :243-252
[5]   Source of induction motor bearing currents caused by PWM inverters [J].
Chen, S ;
Lipo, TA ;
Fitzgerald, D .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1996, 11 (01) :25-32
[6]  
Chen S, 1998, IEEE IND APPL MAGAZI
[7]  
Dahl D., 2008, IEEE IND APPL MAGAZI, V14
[8]  
Electro Static Technology, 2010, PROTECTING VFD DRIVE
[9]  
Humbert S., 2008, SKF MAINTENANCE PROD
[10]   Mitigation of bearing electro-erosion of inverter-fed motors through passive common-mode voltage suppression [J].
Hyypio, D .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (02) :576-583