Development of transportable gamma-ray tomographic system for industrial application

被引:16
作者
Kim, Jongbum [1 ]
Jung, Sung-hee [1 ]
Moon, Jinho [1 ]
Park, Jang Guen [1 ]
Jin, Joonha [1 ]
Cho, Gyuseong [2 ]
机构
[1] Korea Atom Energy Res Inst, Taejon, South Korea
[2] Korea Adv Inst Sci & Technol, Taejon 305701, South Korea
关键词
Transportable system; Gamma-ray; Computed tomography; Transmission scan; Industrial plant;
D O I
10.1016/j.nima.2012.07.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper introduces a gamma-ray tomographic system which is transportable and can be used for on-line systems such as a pipeline operation. In a previous study, a feasibility study on a gamma-ray tomographic system with a scanning geometry of Electron Beam CT was carried out by Monte Carlo simulation. This paper contains a successive work on a previous study by developing and evaluating a real system. To construct a gamma-ray CT, Cs-137 was used as a gamma-ray source and radiation measurement system with 72 channel CsI detectors whose crystal is a 12 mm x 12 mm x 20 mm rectangular parallelepiped was developed to operate jointly with a motion control system. ML-EM algorithm was used for image reconstruction of experimental data. Using the developed transportable gamma-ray system, laboratory and field experiments were carried out successfully. The field experiment results show that a gamma-ray CT with an Electron Beam CT scanning geometry can be a transportable gantry for objects which are parts of processes. Crown Copyright (c) 2012 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:203 / 208
页数:6
相关论文
共 18 条
[1]   CARDIAC COMPUTED-TOMOGRAPHY [J].
BOYD, DP ;
LIPTON, MJ .
PROCEEDINGS OF THE IEEE, 1983, 71 (03) :298-307
[2]   Measurement of liquid flow distribution in trickle bed reactor of large diameter with a new gamma-ray tomographic system [J].
Boyer, C ;
Fanget, B .
CHEMICAL ENGINEERING SCIENCE, 2002, 57 (07) :1079-1089
[3]  
Charlton J. S., 1986, RADIOISOTOPE TRACER
[4]  
Fessler J., 2007, NUCL INSTRUMENTS M A, V572, P668
[5]   An ultra fast electron beam x-ray tomography scanner [J].
Fischer, F. ;
Hoppe, D. ;
Schleicher, E. ;
Mattausch, G. ;
Flaske, H. ;
Bartel, R. ;
Hampel, U. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
[6]  
Fitzpatrick J.M., 2001, HDB MED IMAGING, V2
[7]   Measurement of fluid distributions in a rotating fluid coupling using high resolution gamma ray tomography [J].
Hampel, U. ;
Hoppe, D. ;
Bieberle, A. ;
Kernchen, R. ;
Diele, K. -H. ;
Schleicher, E. ;
da Silva, M. J. ;
Zippe, C. .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (09) :0914021-0914028
[8]  
Industrial Process Gamma Tomography IAEA, 2008, TECDOC1589 IAEA
[9]   Nuclear tomography methods in industry [J].
Johansen, GA .
NUCLEAR PHYSICS A, 2005, 752 :696C-705C
[10]  
Jongbum Kim, 2006, NUCL ENG TECHNOL, V38, P384