Modeling of changes in thermal bioclimate: examples based on urban spaces in Freiburg, Germany

被引:76
作者
Froehlich, Dominik [1 ]
Matzarakis, Andreas [1 ]
机构
[1] Univ Freiburg, Inst Meteorol, D-79085 Freiburg, Germany
关键词
COMFORT; SUMMER; ENVIRONMENT; WEATHER;
D O I
10.1007/s00704-012-0678-y
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The Place of the Old Synagogue is a popular place in the city center of Freiburg, a medium-sized city in southwest Germany. It is going to be redesigned soon. In this paper the impact of urban street design and surface material on human thermal comfort is analyzed using the example of the Place of the Old Synagogue. The models SkyHelios, RayMan, and ENVI-met were applied to quantify and qualify the changes. All three models are freely available. Their combination allows analysis of development in long-term conditions, as well as changes in spatial distribution of thermal comfort, as well as of heat stress in summer. Results show that the models can provide valuable information. About the Place of the Old Synagogue, quantitative results show that the period with heat stress will become longer, while the intensity of heat stress increases. The spatial results show that the most significant changes are due to changes in shading. Nevertheless, an increase in thermal stress up to 10 A degrees C is calculated for areas, where ground coverage changes from grass to pavement.
引用
收藏
页码:547 / 558
页数:12
相关论文
共 32 条
[1]  
[Anonymous], DMG MITTEILUNGEN
[2]  
[Anonymous], 1972, P S THERMAL COMFORT
[3]   Characteristics of permeable pavement during hot summer weather and impact on the thermal environment [J].
Asaeda, T ;
Ca, VT .
BUILDING AND ENVIRONMENT, 2000, 35 (04) :363-375
[4]  
Bruse M., 1999, THESIS U BOCHUM GERM
[5]   Vegetation in the urban environment: microclimatic analysis and benefits [J].
Dimoudi, A ;
Nikolopoulou, M .
ENERGY AND BUILDINGS, 2003, 35 (01) :69-76
[6]   Assessment of the microclimatic and human comfort conditions in a complex urban environment:: Modelling and measurements [J].
Gulyas, Agnes ;
Unger, Janos ;
Matzarakis, Andreas .
BUILDING AND ENVIRONMENT, 2006, 41 (12) :1713-1722
[7]  
Hammerle M., 2011, Acta Climatologica et Chorologica, V44-45, P83
[8]   Comparison of models calculating the sky view factor used for urban climate investigations [J].
Hammerle, Martin ;
Gal, Tamas ;
Unger, Janos ;
Matzarakis, Andreas .
THEORETICAL AND APPLIED CLIMATOLOGY, 2011, 105 (3-4) :521-527
[9]   The physiological equivalent temperature -: a universal index for the biometeorological assessment of the thermal environment [J].
Höppe, P .
INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1999, 43 (02) :71-75
[10]  
Hoppe PR, 1984, THESIS U MUNCHEN, P49