A Point-of-Care Digital Workflow for 3D Printed Passive Presurgical Orthopedic Plates in Cleft Care

被引:15
作者
Zarean, Parichehr [1 ,2 ]
Zarean, Paridokht [1 ,2 ]
Thieringer, Florian M. [1 ,2 ]
Mueller, Andreas A. [1 ,3 ,4 ]
Kressmann, Sabine [1 ]
Erismann, Martin [1 ,3 ,4 ]
Sharma, Neha [1 ,2 ]
Benitez, Benito K. [1 ,3 ,4 ]
机构
[1] Univ Basel, Univ Hosp Basel, Oral & Craniomaxillofacial Surg, Spitalstr 21, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Med Addit Mfg Res Grp Swiss MAM, Gewerbestr 14, CH-4123 Allschwil, Switzerland
[3] Univ Basel, Dept Clin Res, Facial & Cranial Anomalies Res Grp, Spitalstr 12, CH-4031 Basel, Switzerland
[4] Univ Basel, Dept Biomed Engn, Spitalstr 12, CH-4031 Basel, Switzerland
来源
CHILDREN-BASEL | 2022年 / 9卷 / 08期
关键词
cleft lip; cleft palate; 3-Dimensional printing; computer-aided design; presurgical orthopedics; intraoral scanning; LIP; INFANTS; APPLIANCE; REPAIR; NOSE;
D O I
10.3390/children9081261
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Cleft lip and palate are one of the most common congenital craniofacial malformations. As an initial treatment, presurgical orthopedics is considered standard treatment at many cleft centers. Digital impressions are becoming feasible in cleft care. Computer-aided design (CAD) and three-dimensional (3D) printing are manufacturing standards in dentistry. The assimilation of these technologies has the potential to alter the traditional workflow for the fabrication of customized presurgical orthopedic plates. We present a digital workflow comprising three steps: 3D digital image acquisition with an intraoral scanner, open-source CAD modeling, and point-of-care 3D printing for the fabrication of personalized passive presurgical plates for newborns with cleft lip and palate. The digital workflow resulted in patient-related benefits, such as no risk of airway obstruction with quicker data acquisition (range 1-2.5 min). Throughput time was higher in the digital workflow 260-350 min compared to 135 min in the conventional workflow. The manual and personal intervention time was reduced from 135 min to 60 min. We show a clinically useful digital workflow for presurgical plates in cleft treatment. Once care providers overcome procurement costs, digital impressions, and point-of-care 3D printing will simplify these workflows and have the potential to become standard for cleft care.
引用
收藏
页数:12
相关论文
共 32 条
  • [1] What Is the Burden of Care of Nasoalveolar Molding?
    Alfonso, Allyson R.
    Ramly, Elie P.
    Kantar, Rami S.
    Wang, Maxime M.
    Eisemann, Bradley S.
    Staffenberg, David A.
    Shetye, Pradip R.
    Flores, Roberto L.
    [J]. CLEFT PALATE CRANIOFACIAL JOURNAL, 2020, 57 (09) : 1078 - 1092
  • [2] Accuracy Evaluation of Additively and Subtractively Fabricated Palatal Plate Orthodontic Appliances for Newborns and Infants-An In Vitro Study
    Aretxabaleta, Maite
    Unkovskiy, Alexey
    Koos, Bernd
    Spintzyk, Sebastian
    Xepapadeas, Alexander B.
    [J]. MATERIALS, 2021, 14 (15)
  • [3] Bauer Franz X., 2016, Current Directions in Biomedical Engineering, V2, P701, DOI 10.1515/cdbme-2016-0152
  • [4] Digital impressions from newborns to preschoolers with cleft lip and palate: A two-centers experience
    Benitez, Benito K.
    Brudnicki, Andrzej
    Surowiec, Zbigniew
    Wieprzowski, Lukasz
    Rasadurai, Abeelan
    Nalabothu, Prasad
    Lill, Yoriko
    Mueller, Andreas A.
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (11) : 4233 - 4242
  • [5] Continuous circular closure in unilateral cleft lip and plate repair in one surgery
    Benitez, Benito K.
    Brudnicki, Andrzej
    Surowiec, Zbigniew
    Singh, Ravi K.
    Nalabothu, Prasad
    Schumann, Dieter
    Mueller, Andreas A.
    [J]. JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2022, 50 (01) : 76 - 85
  • [6] Histologic Aspect of the Curved Vomerine Mucosa in Cleft Lip and Palate
    Benitez, Benito K.
    Brudnicki, Andrzej
    Nalabothu, Prasad
    von Jackowski, Jeannette A.
    Bruder, Elisabeth
    Mueller, Andreas Albert
    [J]. CLEFT PALATE-CRANIOFACIAL JOURNAL, 2022, 59 (08) : 1048 - 1055
  • [7] Botnar Research Center for Child Health Home Page, US
  • [8] Chate R A, 1995, Br J Orthod, V22, P299
  • [9] Accuracy of CAD/CAM Digital Impressions with Different Intraoral Scanner Parameters
    Chiu, Asher
    Chen, Yen-Wei
    Hayashi, Juri
    Sadr, Alireza
    [J]. SENSORS, 2020, 20 (04)
  • [10] Evaluation of the Clinical Effectiveness of Nasoalveolar Molding (NAM) Using Grayson Method Versus Computer-Aided Design NAM (CAD/NAM) in Infants With Bilateral Cleft Lip and Palate: A Randomized Clinical Trial
    El-Ashmawi, Noha A.
    Fayed, Mona M. Salah
    El-Beialy, Amr
    Attia, Khaled H.
    [J]. CLEFT PALATE-CRANIOFACIAL JOURNAL, 2022, 59 (03) : 377 - 389