Analytical model for the effective strain in FRP-wrapped circular RC columns

被引:38
作者
Lignola, Gian Piero [1 ]
Nardone, Fabio [1 ]
Prota, Andrea [1 ]
Manfredi, Gaetano [1 ]
机构
[1] Univ Naples Federico II, Dept Struct Engn DIST, I-80125 Naples, Italy
关键词
Lamina/ply; Residual/internal stress; Analytical modeling; POLYMER-CONFINED CONCRETE; BEHAVIOR; COMPRESSION; JACKETS; TUBES;
D O I
10.1016/j.compositesb.2012.04.007
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The available models for predicting the ultimate capacity and stress-strain relationships of confined concrete rely on an assumed FRP ultimate strain value. It is commonly assumed that FRP fails when hoop strain in the jacket reaches its ultimate tensile strain determined according to flat coupon tests. However, experimental results of FRP confined concrete showed that in most cases, FRP experimental ultimate tensile strain is clearly not reached at the rupture of the FRP jacket. The discrepancies may include the shape and conditions of concrete substrate as well as defects or stress concentrations in FRP jackets (in particular, the multiaxial stress state in FRP wrapping due to the transfer of loads through the bond with concrete). The present paper covers only issues related to this latter aspect. Since the average absolute error of all confinement models showed a remarkable decrease when the effective FRP hoop strain (smaller than ultimate flat coupon strain) was inserted in the equations, an analytical model to directly evaluate the FRP strain efficiency factor as the strain ratio between the effective FRP hoop strain at failure and the flat coupon test outcomes has been formulated. Multiaxial failure criteria have been adopted (i.e. 3D Tsai-Hill criterion for FRP) in the model considering axial, circumferential and radial stresses. Results of theoretical analyses and experimental tests (experimental data available in literature) have been compared showing a good agreement. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3208 / 3218
页数:11
相关论文
共 23 条
  • [1] [Anonymous], 2008, Guide for the design and construction of externally bonded FRP systems for strengthening concrete structures
  • [2] [Anonymous], 2008, American Society for Testing and Materials
  • [3] Compressive behavior of concrete externally confined by composite jackets. Part A: experimental study
    Berthet, JF
    Ferrier, E
    Hamelin, P
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2005, 19 (03) : 223 - 232
  • [4] Daniel IM, 2006, Engineering mechanics of composite materials
  • [5] Comparative study of models on confinement of concrete cylinders with fiber-reinforced polymer composites
    De Lorenzis, L
    Tepfers, R
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2003, 7 (03) : 219 - 237
  • [6] Structural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns
    De Luca, Antonio
    Nardone, Fabio
    Matta, Fabio
    Nanni, Antonio
    Lignola, Gian Piero
    Prota, Andrea
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2011, 15 (01) : 112 - 123
  • [7] Fam AZ, 2001, ACI STRUCT J, V98, P451
  • [8] On the prediction of the collapse load of circular concrete columns confined by FRP
    Fraldi, M.
    Nunziante, L.
    Carannante, F.
    Prota, A.
    Manfredi, G.
    Cosenza, E.
    [J]. ENGINEERING STRUCTURES, 2008, 30 (11) : 3247 - 3264
  • [9] Shape and "gap" effects on the behavior of variably confined concrete
    Harries, KA
    Carey, SA
    [J]. CEMENT AND CONCRETE RESEARCH, 2003, 33 (06) : 881 - 890
  • [10] Analysis-oriented stress-strain models for FRP-confined concrete
    Jiang, T.
    Teng, J. G.
    [J]. ENGINEERING STRUCTURES, 2007, 29 (11) : 2968 - 2986