A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis

被引:14
作者
Peng, SX [1 ]
Cousineau, M [1 ]
Juzwin, SJ [1 ]
Ritchie, DM [1 ]
机构
[1] Johnson & Johnson Pharmaceut Res & Dev, Raritan, NJ 08869 USA
关键词
D O I
10.1021/ac051514p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples-to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 25 条
  • [1] Collection, storage, and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis
    Berna, M
    Murphy, AT
    Wilken, B
    Ackermann, B
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (05) : 1197 - +
  • [2] Automated protein precipitation by filtration in the 96-well format
    Biddlecombe, RA
    Pleasance, S
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 734 (02): : 257 - 265
  • [3] Bu HZ, 2000, RAPID COMMUN MASS SP, V14, P523, DOI 10.1002/(SICI)1097-0231(20000331)14:6<523::AID-RCM906>3.3.CO
  • [4] 2-K
  • [5] Rapid determination of the anti-cancer drug chlorambucil (Leukeran™) and its phenyl acetic acid mustard metabolite in human serum and plasma by automated solid-phase extraction and liquid chromatography-tandem mass spectrometry
    Davies, ID
    Allanson, JP
    Causon, RC
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01): : 173 - 184
  • [6] Hogberg Thomas, 2005, Drug Discov Today, V10, P820, DOI 10.1016/S1359-6446(05)03490-2
  • [7] Quantitative high-throughput analysis of drugs in biological matrices by mass spectrometry
    Hopfgartner, G
    Bourgogne, E
    [J]. MASS SPECTROMETRY REVIEWS, 2003, 22 (03) : 195 - 214
  • [8] Direct cocktail analysis of drug discovery compounds in pooled plasma samples using liquid chromatography-tandem mass spectrometry
    Hsieh, YS
    Bryant, MS
    Brisson, JM
    Ng, KK
    Korfmacher, WA
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (02): : 353 - 362
  • [9] Quantitative liquid chromatographic-tandem mass spectrometric determination of reserpine in FVB/N mouse plasma using a "chelating" agent (disodium EDTA) for releasing protein-bound analytes during 96-well liquid-liquid extraction
    Ke, J
    Yancey, M
    Zhang, S
    Lowes, S
    Henion, J
    [J]. JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02): : 369 - 380