Assessment of space proton radiation-induced charge transfer inefficiency in the CCD204 for the Euclid space observatory

被引:21
作者
Gow, J. P. D. [1 ]
Murray, N. J. [1 ]
Holland, A. D. [1 ]
Hall, D. J. [1 ]
Cropper, M. [2 ]
Burt, D. [3 ]
Hopkinson, G. [4 ]
Duvet, L.
机构
[1] Open Univ, Ctr Elect Imaging E2v, Milton Keynes MK7 6AA, Bucks, England
[2] Univ Coll London, Mullard Space Sci Lab, Holmbury RH5 6NT, England
[3] E2v Technol Plc, Chelmsford CM1 2QU, Essex, England
[4] Surrey Satellite Technol Ltd, Sevenoaks TN14 5LJ, England
来源
JOURNAL OF INSTRUMENTATION | 2012年 / 7卷
关键词
Radiation damage evaluation methods; Radiation damage to detector materials (solid state); Detectors for UV; visible and IR photons; MASSES;
D O I
10.1088/1748-0221/7/01/C01030
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Euclid is a medium class European Space Agency mission candidate for launch in 2019 with a primary goal to study the dark universe using the weak lensing and baryonic acoustic oscillations techniques. Weak lensing depends on accurate shape measurements of distant galaxies. Therefore it is beneficial that the effects of radiation-induced charge transfer inefficiency (CTI) in the Euclid CCDs over the course of the 5 year mission at L2 are understood. This will allow, through experimental analysis and modelling techniques, the effects of radiation induced CTI on shape to be decoupled from those of mass inhomogeneities along the line-of-sight. This paper discusses a selection of work from the study that has been undertaken using the e2v CCD204 as part of the initial proton radiation damage assessment for Euclid. The experimental arrangement and procedure are described followed by the results obtained, thereby allowing recommendations to be made on the CCD operating temperature, to provide an insight into CTI effects using an optical background, to assess the benefits of using charge injection on CTI recovery and the effect of the use of two different methods of serial clocking on serial CTI. This work will form the basis of a comparison with a p-channel CCD204 fabricated using the same mask set as the n-channel equivalent. A custom CCD has been designed, based on this work and discussions between e2v technologies plc. and the Euclid consortium, and designated the CCD273.
引用
收藏
页数:11
相关论文
共 23 条
  • [1] [Anonymous], 1932, Astron. Inst. Netherlands
  • [2] [Anonymous], 1967, PHYS TECHNOLOGY SEMI
  • [3] [Anonymous], 1986, Bulletin of the American Astronomical Society
  • [4] [Anonymous], 1999, NASA HUBBL SPAC TEL
  • [5] Probing dark energy using baryonic oscillations in the galaxy power spectrum as a cosmological ruler
    Blake, C
    Glazebrook, K
    [J]. ASTROPHYSICAL JOURNAL, 2003, 594 (02) : 665 - 673
  • [6] Galaxy cluster masses without non-baryonic dark matter
    Brownstein, JR
    Moffat, JW
    [J]. MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2006, 367 (02) : 527 - 540
  • [7] A direct empirical proof of the existence of dark matter
    Clowe, Douglas
    Bradac, Marusa
    Gonzalez, Anthony H.
    Markevitch, Maxim
    Randall, Scott W.
    Jones, Christine
    Zaritsky, Dennis
    [J]. ASTROPHYSICAL JOURNAL, 2006, 648 (02) : L109 - L113
  • [8] CONTENT R, 2008, P SPIE, V7010
  • [9] Cropper M., 2010, P SPIE, V7731
  • [10] Einstein A, 1936, Science, V84, P506, DOI 10.1126/science.84.2188.506