CT and 3D-ultrasound registration for spatial comparison of post-EVAR abdominal aortic aneurysm measurements: A cross-sectional study

被引:3
作者
Rouet, L. [1 ]
Dufour, Cecile [1 ]
Billon, Antoine Collet [1 ]
Bredahl, K. [2 ]
机构
[1] Philips Res France, F-92156 Suresnes, France
[2] Univ Hosp Copenhagen, Dept Vasc Surg, Copenhagen, Denmark
关键词
Abdominal aortic aneurysm; Multi-modality registration; 3D ultrasound; Computed tomography; Stent; COMPUTED-TOMOGRAPHY; ULTRASOUND; DIAMETER; SAC;
D O I
10.1016/j.compmedimag.2019.02.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The aim of the present study is to provide a methodology to register volumes of stented abdominal aortic aneurysm, imaged by 3D-US and CT modalities. After registration, the method enables to compare the spatial location of measurements and AAA size in a common coordinate system. Methods: The study is cross-sectional and compares volumes acquired within a few days, in order to eliminate changes due to the evolution of AAA shape after treatment. The key element is to rely on stent alignment to register the CT and 3D-US volumes, providing access to a patient-specific common spatial coordinate system. In parallel, 3D segmentations are performed and used to extract multi-planar reconstructions at the locations of maximum diameter in each modality. The positions of the planes extracted in each modality, and the MA diameters are finally compared in the common coordinate system. Results: Results are validated on a database of 52 patients. After registrations, results show a mean inter-planar distance of 6.4 +/- 4.5 mm and a mean inter-planar angle of 10.2 +/- 6.7 between CT and 3D-US multi-planar reconstructions. Bland-Altman comparisons of diameter measurements in the CT, US and non-registered volumes are respectively 5.1 +/- 2.8, 3.9 +/- 2.8, 4.6 +/- 3.0 mm. Conclusion: The proposed approach provides both visual and quantitative validations of measurements extracted from multi-modality images of the same pathology, in terms of spatial relationship and diameters. Significance: The present work provides additional confidence in the use of 3D-US without CT for the follow-up of patients with abdominal aortic aneurysms after endovascular treatment. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:49 / 59
页数:11
相关论文
共 13 条
[1]   Follow-up of Aortic Stent Grafts: Comparison of the Volumetric Analysis of the Aneurysm Sac by Ultrasound and CT [J].
Arsicot, Matthieu ;
Lathelize, Hubert ;
Martinez, Robert ;
Marchand, Etienne ;
Picquet, Jean ;
Enon, Bernard .
ANNALS OF VASCULAR SURGERY, 2014, 28 (07) :1618-1628
[2]   Three-dimensional Ultrasound Improves the Accuracy of Diameter Measurement of the Residual Sac in EVAR Patients [J].
Bredahl, K. ;
Taudorf, M. ;
Long, A. ;
Lonn, L. ;
Rouet, L. ;
Ardon, R. ;
Sillesen, H. ;
Eiberg, J. P. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2013, 46 (05) :525-532
[3]   REGISTRATION OF REAL-TIME 3-D ULTRASOUND TOTOMOGRAPHIC IMAGES OF THE ABDOMINAL AORTA [J].
Brekken, Reidar ;
Iversen, Daniel Hoyer ;
Tangen, Geir Arne ;
Dahl, Torbjorn .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (08) :2026-2032
[4]   Three-Dimensional Ultrasonography Measurements After Endovascular Aneurysm Repair [J].
Causey, Marlin Wayne ;
Jayaraj, Arjun ;
Leotta, Daniel F. ;
Paun, Marla ;
Beach, Kirk W. ;
Kohler, Ted R. ;
Zierler, Eugene R. ;
Starnes, Benjamin W. .
ANNALS OF VASCULAR SURGERY, 2013, 27 (02) :146-153
[5]  
Feinen C, 2014, IEEE ENG MED BIO, P6718, DOI 10.1109/EMBC.2014.6945170
[6]   Ultrasound-determined diameter measurements are more accurate than axial computed tomography after endovascular aortic aneurysm repair [J].
Han, Sukgn M. ;
Patel, Kaushel ;
Rowe, Vincent L. ;
Perese, Susana ;
Bond, Aaron ;
Weaver, Fred A. .
JOURNAL OF VASCULAR SURGERY, 2010, 51 (06) :1381-1389
[7]   Measuring the Maximum Diameter of Native Abdominal Aortic Aneurysms: Review and Critical Analysis [J].
Long, A. ;
Rouet, L. ;
Lindholt, J. S. ;
Allaire, E. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 43 (05) :515-524
[8]   Abdominal aortic aneurysm diameter: A comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction [J].
Manning, Brian J. ;
Kristmundsson, Thorarinn ;
Sonesson, Bjorn ;
Resch, Timothy .
JOURNAL OF VASCULAR SURGERY, 2009, 50 (02) :263-268
[9]  
Miao S, 2013, LECT NOTES COMPUT SC, V8149, P380, DOI 10.1007/978-3-642-40811-3_48
[10]   Management of Abdominal Aortic Aneurysms Clinical Practice Guidelines of the European Society for Vascular Surgery [J].
Moll, F. L. ;
Powell, J. T. ;
Fraedrich, G. ;
Verzini, F. ;
Haulon, S. ;
Waltham, M. ;
van Herwaarden, J. A. ;
Holt, P. J. E. ;
van Keulen, J. W. ;
Rantner, B. ;
Schloesser, F. J. V. ;
Setacci, F. ;
Rica, J-B .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2011, 41 :S1-S58