Embedded Sensors for Corrosion Monitoring of Existing Reinforced Concrete Structures

被引:13
|
作者
Pereira, E. V. [1 ]
Figueira, R. B. [1 ]
Salta, M. M. [1 ]
Fonseca, I. T. E. [2 ]
机构
[1] Lab Nacl Engn Civil, Av Brasil 101, P-1700066 Lisbon, Portugal
[2] Univ Lisbon, Fac Ciencias, Dept Quim Bioquim, P-1749016 Lisbon, Portugal
来源
ADVANCED MATERIALS FORUM IV | 2008年 / 587-588卷
关键词
Sensors; corrosion monitoring; durability of concrete;
D O I
10.4028/www.scientific.net/MSF.587-588.677
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this work the performance of two surface treatments and the efficiency of a corrosion inhibitor were evaluated, in the control of steel corrosion in concrete induced by chlorides, through measurements of galvanic current and polarization resistance applied to embedded sensors fixed in existing concrete Using different methodologies. From the results obtained the use of the different embedded sensors in the measurement of corrosion rate is discussed aiming the development of new systems for permanent evaluation of the on site performance of products for repairing reinforced concrete structures affected by reinforcement corrosion.
引用
收藏
页码:677 / +
页数:2
相关论文
共 50 条
  • [41] Embedded fiber-optic sensors in reinforced concrete elements of bridge structures
    Domaneschi, M.
    Cimellaro, G. P.
    Ansari, F.
    Morgese, M.
    Inaudi, D.
    BRIDGE MAINTENANCE, SAFETY, MANAGEMENT, LIFE-CYCLE SUSTAINABILITY AND INNOVATIONS, 2021, : 1657 - 1664
  • [42] Low-Cost, Passive Sensors for Monitoring Corrosion in Concrete Structures
    Abu-Yousef, Ali E.
    Pasupathy, Praveenkumar
    Wood, Sharon L.
    Neikirk, Dean P.
    NONDESTRUCTIVE CHARACTERIZATION FOR COMPOSITE MATERIALS, AEROSPACE ENGINEERING, CIVIL INFRASTRUCTURE, AND HOMELAND SECURITY 2011, 2011, 7983
  • [43] Investigation on novel embedded piezoelectric ultrasonic transducers for corrosion monitoring of reinforced concrete
    Liu, Peng
    Hu, Yan
    Geng, Bo
    Xu, Dongyu
    SMART MATERIALS AND STRUCTURES, 2019, 28 (11)
  • [44] Corrosion detection in reinforced concrete roadways and bridges via embedded fiber optic sensors
    Fuhr, PL
    Huston, DR
    SMART MATERIALS & STRUCTURES, 1998, 7 (02): : 217 - 228
  • [45] Case Study: Corrosion Monitoring of In-Service Reinforced Concrete Structures
    Zafar, Idrees
    Corrosion Management, 2024, (180): : 38 - 41
  • [46] A novel in-situ corrosion monitoring electrode for reinforced concrete structures
    Subbiah, Karthick
    Velu, Saraswathy
    Kwon, Seung-Jun
    Lee, Han-Seung
    Rethinam, Natarajan
    Park, Dong-Jin
    ELECTROCHIMICA ACTA, 2018, 259 : 1129 - 1144
  • [47] Monitoring DIAMOND device for corrosion state evaluation of reinforced concrete structures
    Samson, Gabriel
    Deby, Fabrice
    Garciaz, Jean-Luc
    Perrin, Jean-Louis
    INTERNATIONAL CONFERENCE ON CONCRETE REPAIR, REHABILITATION AND RETROFITTING (ICCRRR 2018), 2018, 199
  • [48] Techniques of corrosion monitoring of steel rebar in reinforced concrete structures: A review
    Fan, Liang
    Shi, Xianming
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2022, 21 (04): : 1879 - 1905
  • [49] An innovative corrosion evaluation technique for reinforced concrete structures using magnetic sensors
    Zhang, Jinrui
    Liu, Chao
    Sun, Ming
    Li, Zongjin
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 135 : 68 - 75
  • [50] Techniques of corrosion monitoring of steel rebar in reinforced concrete structures: A review
    Fan, Liang
    Shi, Xianming
    Structural Health Monitoring, 2022, 21 (04) : 1879 - 1905