Implementation of Passive Autocatalytic Recombiner System as a Hydrogen Mitigation System in Korean Nuclear Power Plants

被引:0
作者
Kim, Chang Hyun [1 ]
Sung, Je Joong [1 ]
Ha, Sang Jun [1 ]
Yeo, In Seon [2 ]
机构
[1] Korea Hydro & Nucl Power Co Ltd, Cent Res Inst, Taejon 305343, South Korea
[2] KEPCO Engn & Construct Co Ltd, Songnam 463870, Gyeonggi Do, South Korea
来源
ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER | 2015年 / 60卷 / 8-9期
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Ensuring the containment integrity during a severe accident in nuclear power reactor by maintaining the hydrogen concentration below an acceptable level has been recognized to be of critical importance since Three Mile Island and Fukushima Daiichi nuclear power plant accidents. Although there exist various mitigation measures for hydrogen risk, a passive autocatalytic recombiner (PAR) has been emphasized as a viable option for the mitigation of hydrogen risk under the extended station blackout conditions due to its passive operation characteristics for the hydrogen removal. To enhance the capability of hydrogen control, the hydrogen mitigation system with various types of PARs has been implemented for all nuclear power plants in Korea. This paper presents an implementation procedure of PAR system and the analysis results to determine the location and capacity of PAR in OPR1000. Various accident scenarios have been adopted considering important event sequences from a combination of probabilistic methods, deterministic methods and sound engineering judgment. A MAAP 4.0.6+ with a multi-compartment model has been used as an analysis tool with conservative hydrogen generation and removal models. The detailed analyses have been performed for selected severe accident scenarios including sensitivity analysis with/without operations of various safety systems. The possibility of global flame acceleration (FA) and deflagration-to-detonation transient (DDT) has been assessed with sigma (flame acceleration potential) and 7-lambda (DDT potential) criterion. It is concluded that the newly designed hydrogen mitigation system with twenty-four (24) PARs can effectively remove containment atmosphere and prevent global FA and DDT.
引用
收藏
页码:512 / +
页数:6
相关论文
共 50 条
[41]   Temperature Profile Mapping over a Catalytic Unit of a Hydrogen Passive Autocatalytic Recombiner: An Experimental and Computational Fluid Dynamics Study [J].
Malakhov, A. A. ;
du Toit, M. H. ;
du Preez, S. P. ;
Avdeenkov, A., V ;
Bessarabov, D. G. .
ENERGY & FUELS, 2020, 34 (09) :11637-11649
[42]   Development of an Ultrasonic Performance Demonstration System for Dissimilar Metal Welds in Korean Nuclear Power Plants [J].
Yoon, Byungsik ;
Yang, Seunghan ;
Kim, Yongsik .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2011, 48 (11) :1403-1411
[43]   Seamless remote dismantling system for heavy and highly radioactive components of Korean nuclear power plants [J].
Hyun, Dongjun ;
Lee, Sung-Uk ;
Seo, Yong-Chil ;
Kim, Geun-Ho ;
Lee, Jonghwan ;
Jeong, Kwan-Seong ;
Choi, Byung-Seon ;
Moon, Jei-Kwon .
ANNALS OF NUCLEAR ENERGY, 2014, 73 :39-45
[44]   Development of an ultrasonic performance demonstration system for dissimilar metal welds in Korean nuclear power plants [J].
Korea Electric Power Research Institute, 103-16 Munji-Dong, Yuseung-Gu, Daejeon 305-380, Korea, Republic of .
J Nucl Sci Technol, 11 (1403-1411)
[45]   Harmonics Mitigation of Industrial Power System Using Passive Filters [J].
Memon, Zubair Ahmed ;
Uquaili, Mohammad Aslam ;
Unar, Mukhtiar Ali .
MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2012, 31 (02) :355-360
[46]   A design and implementation of a fault-tolerant rod control system for nuclear power plants [J].
Kwon, Soonman ;
Cheon, Jong-Min ;
Lee, Jongmoo ;
Kim, Choon-Kyung ;
Kim, Seog-Joo .
2006 IEEE International Symposium on Industrial Electronics, Vols 1-7, 2006, :1933-1936
[47]   Use of optimization and simulation in the implementation of the process automation system of the EDF Nuclear Power Plants [J].
Le Quenven, T ;
Hayward, A .
THIRTIETH HAWAII INTERNATIONAL CONFERENCE ON SYSTEM SCIENCES, VOL 5: ADVANCED TECHNOLOGY, 1997, :144-151
[48]   Safety assessment for the passive system of the nuclear power plants (NPPs) using safety margin estimation [J].
Woo, Tae-Ho ;
Lee, Un-Chul .
ENERGY, 2010, 35 (04) :1799-1804
[49]   Performance Analysis of Water Heat Pipe for Application of the Passive Cooling System in Nuclear Power Plants [J].
Park, Ye Yeong ;
Bang, In Cheol .
NUCLEAR TECHNOLOGY, 2024,
[50]   SURVEILLANCE SYSTEM FOR NUCLEAR POWER PLANTS. [J].
Mizeracki, M.T. .
Proceedings of the Society for Information Display, 1981, :153-158