Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T

被引:21
|
作者
Deelchand, Dinesh K. [1 ]
Auerbach, Edward J.
Marjanska, Malgorzata
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, 2021 6th St SE, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
STEAM; PRESS; ADC; glutamate; myo-inositol; MAGNETIC-RESONANCE-SPECTROSCOPY; MR SPECTROSCOPY; NMR-SPECTROSCOPY; RAT-BRAIN; 7; T; WEIGHTED SPECTROSCOPY; WHITE-MATTER; SPIN SYSTEMS; ECHO; SEQUENCE;
D O I
10.1002/mrm.26969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffusion gradients. MethodsDiffusion-weighted spectra were acquired from the prefrontal cortex in five healthy subjects using STEAM (echo time [TE]/mixing time [TM]/pulse repetition time [TR]=21.22/105/3000 ms, b-values=0 and 3172 s/mm(2)) and PRESS (TE/TR=54.2/3000 ms, b-values=0 and 2204 s/mm(2)). Diffusion weighting was applied using bipolar gradients in three orthogonal directions. Post-processed spectra were analyzed with LCModel, and the trace/3 ADC values were calculated. ResultsComparable trace/3 ADC values (0.14-0.18 mu m(2)/ms) were obtained for five main metabolites with both methods. These metabolites were quantified with Cramer-Rao lower bounds below 15%. ConclusionThe ADC values of the five main metabolites were successfully measured in the human brain at 3T with eliminated directional dependence. Both STEAM and PRESS can be used to probe the diffusivity of metabolites in normal brain and various pathologies on the clinical scanner with slightly higher precision achieved with STEAM for glutamate and myo-inositol. Magn Reson Med 79:2896-2901, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:2896 / 2901
页数:6
相关论文
共 50 条
  • [21] Preoperative histological grading of meningiomas using apparent diffusion coefficient at 3T MRI
    Watanabe, Yosuke
    Yamasaki, Fumiyuki
    Kajiwara, Yoshinori
    Takayasu, Takeshi
    Nosaka, Ryo
    Akiyama, Yuji
    Sugiyama, Kazuhiko
    Kurisu, Kaoru
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (04) : 658 - 663
  • [22] Apparent diffusion coefficient reproducibility in brain tumors measured on 1.5 and 3 T clinical scanners: A pilot study
    Merhemic, Zulejha
    Imsirovic, Bilal
    Bilalovic, Nurija
    Stojanov, Dragan
    Boban, Jasmina
    Thurnher, Majda M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 249 - 253
  • [23] Metabolic heterogeneity of the normal human brain: multivariate analysis of 1H MRS in vivo spectra acquired at 3T
    Skorupa, Agnieszka
    Boguszewicz, Lukasz
    Kijonka, Marek
    Sokol, Maria
    METABOLOMICS, 2017, 13 (04)
  • [24] Diffusion-weighted MRI at 3T in Endometrial Cancer: Correlation of Apparent Diffusion Coefficient with Histopathological Prognostic Parameters
    Ozturk, Mesut
    Kalkan, Cihan
    Danaci, Murat
    Kefeli, Mehmet
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2021, 31 (12): : 1399 - 1405
  • [25] In Vivo 1H MRSI of Glycine in Brain Tumors at 3T
    Ganji, Sandeep K.
    Maher, Elizabeth A.
    Choi, Changho
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (01) : 52 - 62
  • [26] Effects of Aging on the Human Brain: A Proton and Phosphorus MR Spectroscopy Study at 3T
    Schmitz, Birte
    Wang, Xin
    Barker, Peter B.
    Pilatus, Ulrich
    Bronzlik, Paul
    Dadak, Mete
    Kahl, Kai G.
    Lanfermann, Heinrich
    Ding, Xiao-Qi
    JOURNAL OF NEUROIMAGING, 2018, 28 (04) : 416 - 421
  • [27] Apparent diffusion coefficient and T2* mapping on 3T MRI in normal and degenerative lumbar intervertebral discs
    Kapoor, Reetika
    Rangankar, Varsha Purushottam
    Kumar, Divyajat
    Raina, Shashank
    Revikumar, Akhil
    Mohanan, Karthik
    POLISH JOURNAL OF RADIOLOGY, 2023, 88 : E275 - E285
  • [28] Detection of 2-hydroxyglutarate in brain tumors by triple-refocusing MR spectroscopy at 3T in vivo
    An, Zhongxu
    Ganji, Sandeep K.
    Tiwari, Vivek
    Pinho, Marco C.
    Patel, Toral
    Barnett, Samuel
    Pan, Edward
    Mickey, Bruce E.
    Maher, Elizabeth A.
    Choi, Changho
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) : 40 - 48
  • [29] Dynamic 1H-MRS for detection of 13C-labeled glucose metabolism in the human brain at 3T
    Dehghani, Masoumeh
    Zhang, Steven
    Kumaragamage, Chathura
    Rosa-Neto, Pedro
    Near, Jamie
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (03) : 1140 - 1151
  • [30] Quantitative Susceptibility Mapping of Human Brain at 3T: A Multisite Reproducibility Study
    Lin, P-Y
    Chao, T-C.
    Wu, M-L.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 467 - 474