Apparent diffusion coefficients of the five major metabolites measured in the human brain in vivo at 3T

被引:21
|
作者
Deelchand, Dinesh K. [1 ]
Auerbach, Edward J.
Marjanska, Malgorzata
机构
[1] Univ Minnesota, Ctr Magnet Resonance Res, 2021 6th St SE, Minneapolis, MN 55455 USA
基金
美国国家卫生研究院;
关键词
STEAM; PRESS; ADC; glutamate; myo-inositol; MAGNETIC-RESONANCE-SPECTROSCOPY; MR SPECTROSCOPY; NMR-SPECTROSCOPY; RAT-BRAIN; 7; T; WEIGHTED SPECTROSCOPY; WHITE-MATTER; SPIN SYSTEMS; ECHO; SEQUENCE;
D O I
10.1002/mrm.26969
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo measure the apparent diffusion coefficients (ADC) of five main metabolites in the human brain at 3T with PRESS and STEAM, avoiding measurement biases because of cross-terms. Cross-terms arise from interactions between slice-selection and spoiler gradients in the localized spectroscopy sequence and the diffusion gradients. MethodsDiffusion-weighted spectra were acquired from the prefrontal cortex in five healthy subjects using STEAM (echo time [TE]/mixing time [TM]/pulse repetition time [TR]=21.22/105/3000 ms, b-values=0 and 3172 s/mm(2)) and PRESS (TE/TR=54.2/3000 ms, b-values=0 and 2204 s/mm(2)). Diffusion weighting was applied using bipolar gradients in three orthogonal directions. Post-processed spectra were analyzed with LCModel, and the trace/3 ADC values were calculated. ResultsComparable trace/3 ADC values (0.14-0.18 mu m(2)/ms) were obtained for five main metabolites with both methods. These metabolites were quantified with Cramer-Rao lower bounds below 15%. ConclusionThe ADC values of the five main metabolites were successfully measured in the human brain at 3T with eliminated directional dependence. Both STEAM and PRESS can be used to probe the diffusivity of metabolites in normal brain and various pathologies on the clinical scanner with slightly higher precision achieved with STEAM for glutamate and myo-inositol. Magn Reson Med 79:2896-2901, 2018. (c) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:2896 / 2901
页数:6
相关论文
共 50 条
  • [1] Differences in apparent diffusion coefficients of brain metabolites between grey and white matter in the human brain measured at 7 T
    Kan, Hermien E.
    Techawiboonwong, Aranee
    van Osch, Matthias J. P.
    Versluis, Maarten J.
    Deelchand, Dinesh K.
    Henry, Pierre-Gilles
    Marjanska, Malgorzata
    van Buchem, Mark A.
    Webb, Andrew G.
    Ronen, Itamar
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (05) : 1203 - 1209
  • [2] Transverse relaxation time constants of the five major metabolites in human brain measured in vivo using LASER and PRESS at 3 T
    Deelchand, Dinesh K.
    Auerbach, Edward J.
    Kobayashi, Naoharu
    Marjanska, Malgorzata
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1260 - 1265
  • [3] T2 measurement of J-coupled metabolites in the human brain at 3T
    Ganji, Sandeep K.
    Banerjee, Abhishek
    Patel, Aditya M.
    Zhao, Yan D.
    Dimitrov, Ivan E.
    Browning, Jeffrey D.
    Brown, E. Sherwood
    Maher, Elizabeth A.
    Choi, Changho
    NMR IN BIOMEDICINE, 2012, 25 (04) : 523 - 529
  • [4] Utility of Apparent Diffusion Coefficients in the Evaluation of Solid Renal Tumors at 3T
    Sasamori, Hiroto
    Saiki, Makoto
    Suyama, Jumpei
    Ohgiya, Yoshimitsu
    Hirose, Masanori
    Gokan, Takehiko
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (02) : 89 - 95
  • [5] The interaction between apparent diffusion coefficients and transverse relaxation rates of human brain metabolites and water studied by diffusion- weighted spectroscopy at 7 T
    Branzoli, Francesca
    Ercan, Ece
    Webb, Andrew
    Ronen, Itamar
    NMR IN BIOMEDICINE, 2014, 27 (05) : 495 - 506
  • [6] Age-Trajectories of Higher-Order Diffusion Properties of Major Brain Metabolites in Cerebral and Cerebellar Gray Matter Using In Vivo Diffusion-Weighted MR Spectroscopy at 3T
    Simsek, Kadir
    Gallea, Cecile
    Genovese, Guglielmo
    Lehericy, Stephane
    Branzoli, Francesca
    Palombo, Marco
    AGING CELL, 2025,
  • [7] Reproducibility and optimization of in vivo human diffusion-weighted MRS of the corpus callosum at 3T and 7T
    Wood, Emily T.
    Ercan, Ayse Ece
    Branzoli, Francesca
    Webb, Andrew
    Sati, Pascal
    Reich, Daniel S.
    Ronen, Itamar
    NMR IN BIOMEDICINE, 2015, 28 (08) : 976 - 987
  • [8] In vivo estimation of transverse relaxation time constant (T2) of 17 human brain metabolites at 3T
    Wyss, Patrik O.
    Bianchini, Claudio
    Scheidegger, Milan
    Giapitzakis, Ioannis A.
    Hock, Andreas
    Fuchs, Alexander
    Henning, Anke
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 452 - 461
  • [9] Measurement of glutathione in human brain at 3T using an improved double quantum filter in vivo
    Choi, Changho
    Zhao, Chenguang
    Dimitrov, Ivan
    Douglas, Deborah
    Coupland, Nicholas J.
    Kalra, Sanjay
    Hawesa, Halima
    Davis, Jeannie
    JOURNAL OF MAGNETIC RESONANCE, 2009, 198 (02) : 160 - 166
  • [10] In vivo measurement of apparent diffusion coefficients of hyperpolarized 13C-labeled metabolites
    Sogaard, Lise Vejby
    Schilling, Franz
    Janich, Martin A.
    Menzel, Marion I.
    Ardenkjaer-Larsen, Jan Henrik
    NMR IN BIOMEDICINE, 2014, 27 (05) : 561 - 569