Ultrasonic Detection Method for Grouted Defects in Grouted Splice Sleeve Connector Based on Wavelet Pack Energy

被引:28
作者
Li, Zuohua [1 ]
Zheng, Lilin [1 ]
Chen, Chaojun [1 ]
Long, Zhili [2 ]
Wang, Ying [3 ]
机构
[1] Harbin Inst Technol, Sch Civil & Environm Engn, Shenzhen 518055, Peoples R China
[2] Harbin Inst Technol, Sch Mech Engn & Automat, Shenzhen 518055, Peoples R China
[3] Univ Surrey, Dept Civil & Environm Engn, Guildford GU2 7XH, Surrey, England
关键词
grouted splice sleeve connector; precast concrete structure; ultrasonic detection method; wavelet packet energy; grouted defect; PULSE VELOCITY; BOND STRENGTH; CONCRETE;
D O I
10.3390/s19071642
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Grouted splice sleeve (GSS) connectors are mainly used in precast concrete structures. However, errors in manual operation during construction cause grouted defects in the GSS connector, which can lead to a negative effect on the overall mechanical properties of the structures. Owing to the complex structure of precast concrete members with a GSS connector, it is difficult to detect grouted defects effectively using traditional ultrasonic parameters. In this paper, a wavelet packet analysis algorithm was developed to effectively detect grouted defects using the ultrasonic method, and a verified experiment was carried out. Laboratory detection was performed on the concrete specimens with a GSS connector before grouting, in which the grouted defects were mimicked with five sizes in five GSS connectors of each specimen group. A simple and convenient ultrasonic detection system was developed, and the specimens were detected. According to the proposed grouted defect index, the results demonstrated that when the grouted defects reached certain sizes, the proposed method could detect the grouted defects effectively. The proposed method is effective and easy to implement at a construction site with simple instruments, and so provides an innovative method for grouted defects detection of precast concrete members.
引用
收藏
页数:17
相关论文
共 30 条
  • [1] Compressive strength evaluation of structural lightweight concrete by non-destructive ultrasonic pulse velocity method
    Alexandre Bogas, J.
    Gloria Gomes, M.
    Gomes, Augusto
    [J]. ULTRASONICS, 2013, 53 (05) : 962 - 972
  • [2] [Anonymous], 2018, CONSTR TECHNOL
  • [3] [Anonymous], NDT
  • [4] Void detection beneath reinforced concrete sections: The practical application of ground-penetrating radar and ultrasonic techniques
    Cassidy, Nigel J.
    Eddies, Rod
    Dods, Sam
    [J]. JOURNAL OF APPLIED GEOPHYSICS, 2011, 74 (04) : 263 - 276
  • [5] Cheesman J.R., 1949, American Concrete Institute, V46, P17
  • [6] Gao R.D., 2017, NONDESTRUCT TEST, V4, P12
  • [7] Joel E.P., 2014, THESIS
  • [8] Nonlinear FE analysis of slab-beam-column connection in precast concrete structures
    Kataoka, Marcela Novischi
    Ferreira, Marcelo Araujo
    Homce de Cresce El Debs, Ana Lucia
    [J]. ENGINEERING STRUCTURES, 2017, 143 : 306 - 315
  • [9] Bond Strength of Mortar-filled Steel Pipe Splices Reflecting Confining Effect
    Kim, Hyong-Kee
    [J]. JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2012, 11 (01) : 125 - 132
  • [10] Performance of a precast concrete beam-to-beam connection subject to reversed cyclic loading
    Korkmaz, HH