Image display for collision avoidance of radiation therapy: Treatment planning

被引:16
作者
Chao, MM
Chao, LS
Chen, YJ
Hsieh, CM
Liou, SC
Lee, YL
Yen, SH
机构
[1] Vet Gen Hosp, Ctr Canc, Taipei, Taiwan
[2] Vet Gen Hosp, Canc Res Grp, Taipei, Taiwan
关键词
image display; collision avoidance; treatment planning;
D O I
10.1053/jdim.2001.31014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Patient treatment in a medical linear accelerator is characterized by many angular and translational movements of the gantry and couch. The direction and orientation of each treatment beam is specified by a set of gantry, turntable, and collimator angles. It is possible that some selected treatment field configurations will result in gantry/couch or gantry/patient collisions that remain undetected during the treatment planning process. In this work, a digital camera has been used to record all the workable gantry/patient set-up images, and a Windows programming language is used to edit and display these images on a personal computer for the treatment planner to screen the treatment plans. These graphical displays enable the planner to be aware of any potential collision hazards by an actual visualization of each selected gantry/turntable or gantry/patient angle configuration. Copyright (C) 2001 by W.B. Saunders Company.
引用
收藏
页码:186 / 191
页数:6
相关论文
共 20 条
[1]  
[Anonymous], 6093111996 IEC
[2]   The pocket linac: A hand-held device for finding IEC collimator angles and independent jaw settings [J].
Appleby, HJ .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (03) :311-313
[3]  
Bayouth J. E., 1995, International Journal of Radiation Oncology Biology Physics, V32, P188
[4]   A collision prevention software tool for complex three-dimensional isocentric set-ups [J].
Beange, I ;
Nisbet, A .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (869) :537-541
[5]   OPTIMIZATION OF BEAM ORIENTATIONS IN RADIATION-THERAPY - SOME THEORETICAL CONSIDERATIONS [J].
BORTFELD, T ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (02) :291-304
[6]  
COMER DE, 1993, INTERNETWORKING TCP, V3
[7]  
Everett H. R., 1989, Robotics and Autonomous Systems, V5, P5
[8]   Collision detection and avoidance during treatment planning [J].
Humm, JL ;
Pizzuto, D ;
Fleischman, E ;
Mohan, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1101-1108
[9]   COLLISION-AVOIDANCE IN COMPUTER-OPTIMIZED TREATMENT PLANNING [J].
HUMM, JL .
MEDICAL PHYSICS, 1994, 21 (07) :1053-1064
[10]   A computer-controlled conformal radiotherapy system .3. Graphical simulation and monitoring of treatment delivery [J].
Kessler, ML ;
McShan, DL ;
Fraass, BA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1173-1180