Effect of Palatal Metal Collar's Height on Fracture Resistance of Single Metal-Ceramic Crowns

被引:2
作者
Aburaisi, Nour [1 ]
Elbishari, Haitham [2 ]
机构
[1] Dr Sulaiman Al Habib Hosp, Restorat Dentist, Khobar, Saudi Arabia
[2] Mohammed Bin Rashid Univ Med & Hlth Sci MBRU, Hamdan Bin Mohammed Coll Dent Med HBMCDM, Dept Prosthodont, Dubai, U Arab Emirates
关键词
PORCELAIN; RESTORATIONS; STRENGTH; MARGINS; LOAD;
D O I
10.1155/2022/8290538
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purpose of this study is to evaluate the effect of the palatal metal collar height on the fracture resistance of metal-ceramic crowns. Materials and Methods. A maxillary premolar typodont tooth was prepared and scanned to fabricate 48 metal analogs. The analogs were then scanned to fabricate metal copings divided into 4 groups according to palatal metal collar height as follows; (C0): 0 mm, (C1): 1.0 mm, (C2): 1.5 mm, and (C3): 2.0 mm. After a standard application of pressed ceramic, each crown was cemented onto its corresponding metal tooth analog. The crown-analog assembly was subjected to a sequence of thermal stressing for 5,000 cycles. A universal testing machine applied controlled loads to the crowns until fracture. Examination under a stereomicroscope determined the failure mode. A scanning electron microscope (SEM) was used to examine fracture. Load to failure data was analyzed using ANOVA followed by Tukey HSD (P & LE;0.05). Results. ANOVA statistics revealed that groups with a palatal metal collar presented significantly higher failure loads when compared to the collarless group (P < 0.0001). Difference in failure loads between 1.5-mm and 2.0-mm palatal metal collar height were not statistically significant (P=0.935). There were no significant differences detected among the groups in terms of failure mode. Conclusions. The height of the palatal metal collar has an effect on the fracture resistance of the metal-ceramic crowns. Clinical Relevance. The incorporation of a palatal collar with a predetermined height is essential to reduce the mechanical failure of metal-ceramic crowns.
引用
收藏
页数:9
相关论文
共 50 条
[41]   Marginal Fit of Metal-Ceramic Copings: Effect of Luting Cements and Tooth Preparation Design [J].
dos Santos Paes de Almeida, Juliana Gomes ;
Guedes, Carlos Gramani ;
Abi-Rached, Filipe de Oliveira ;
Trindade, Flavia Zardo ;
Fonseca, Renata Garcia .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01) :E265-E270
[42]   The Effect of Occlusal Surface Relief of Dies on Marginal Adaptation of Metal-Ceramic Casting Copings [J].
Saber, Fariba Saleh ;
Abolfazli, Nader ;
Mahboub, Farhang ;
Razavi, Fariba Emadian .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2013, 22 (04) :287-291
[43]   Metal-ceramic and porcelain-veneered lithium disilicate crowns: a stress profile comparison using a viscoelastic finite element model [J].
Dhital, Sukirti ;
Rodrigues, Camila ;
Zhang, Yu ;
Kim, Jeongho .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (04) :412-423
[44]   Influence of firing conditions and production methods on fracture strength of titanium-based metal ceramic crowns [J].
Haag, P. ;
Khan, F. ;
Andersson, M. ;
von Steyern, P. Vult .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2018, 32 (03) :225-238
[45]   The Effect of Thermocycling and Mechanical Loading on the Fracture Resistance of Graphene and All-Ceramic Anterior Crowns [J].
Reddy, Karri Akhil Sai ;
Prasad, B. Rajendra ;
Darshini, Reddy Priya ;
Challa, Sai Ram ;
Charishma, Mondreti Naga ;
Sowjanya, Sangani ;
Devi, Kakarlapudi Akhila ;
Turlapati, Sai Swetha ;
Teja, Pathuri Raveen .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
[46]   Effect of Incisal Porcelain Veneering Thickness on the Fracture Resistance of CAD/CAM Zirconia All-Ceramic Anterior Crowns [J].
Badran, Noha ;
Kader, Sanaa Abdel ;
Alabbassy, Fayza .
INTERNATIONAL JOURNAL OF DENTISTRY, 2019, 2019
[47]   Monolithic zirconia as a valid alternative to metal-ceramic for implant-supported single crowns in the posterior region: A systematic review and meta-analysis of randomized controlled trials [J].
Tajti, Peter ;
Solyom, Eleonora ;
Czumbel, Laszlo Mark ;
Szabo, Bence ;
Fazekas, Reka ;
Nemeth, Orsolya ;
Hermann, Peter ;
Gerber, Gabor ;
Hegyi, Peter ;
Mikulas, Krisztina .
JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (05) :881-889
[48]   Development of a structural and rheological model for investigation of peculiarities of deformation and fracture of metal-ceramic composites with multimodal internal structure [J].
Astafurov, S. V. ;
Shilko, E. V. ;
Ovcharenko, V. E. ;
Dimaki, A. V. ;
Psakhie, S. G. .
20TH EUROPEAN CONFERENCE ON FRACTURE, 2014, 3 :568-573
[49]   Galvano- vs. metal-ceramic crowns: up to 5-year results of a randomised split-mouth study [J].
Naumann, Michael ;
Ernst, Juliane ;
Reich, Sven ;
Weisshaupt, Peggy ;
Beuer, Florian .
CLINICAL ORAL INVESTIGATIONS, 2011, 15 (05) :657-660
[50]   Marginal and Internal Discrepancies of Posterior Zirconia-Based Crowns Fabricated with Three Different CAD/CAM Systems Versus Metal-Ceramic [J].
Ortega, Rocio ;
Gonzalo, Esther ;
Gomez-Polo, Miguel ;
Suarez, Maria J. .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (05) :509-511