Objectives. The purpose of this study is to evaluate the effect of the palatal metal collar height on the fracture resistance of metal-ceramic crowns. Materials and Methods. A maxillary premolar typodont tooth was prepared and scanned to fabricate 48 metal analogs. The analogs were then scanned to fabricate metal copings divided into 4 groups according to palatal metal collar height as follows; (C0): 0 mm, (C1): 1.0 mm, (C2): 1.5 mm, and (C3): 2.0 mm. After a standard application of pressed ceramic, each crown was cemented onto its corresponding metal tooth analog. The crown-analog assembly was subjected to a sequence of thermal stressing for 5,000 cycles. A universal testing machine applied controlled loads to the crowns until fracture. Examination under a stereomicroscope determined the failure mode. A scanning electron microscope (SEM) was used to examine fracture. Load to failure data was analyzed using ANOVA followed by Tukey HSD (P & LE;0.05). Results. ANOVA statistics revealed that groups with a palatal metal collar presented significantly higher failure loads when compared to the collarless group (P < 0.0001). Difference in failure loads between 1.5-mm and 2.0-mm palatal metal collar height were not statistically significant (P=0.935). There were no significant differences detected among the groups in terms of failure mode. Conclusions. The height of the palatal metal collar has an effect on the fracture resistance of the metal-ceramic crowns. Clinical Relevance. The incorporation of a palatal collar with a predetermined height is essential to reduce the mechanical failure of metal-ceramic crowns.
引用
收藏
页数:9
相关论文
共 50 条
[31]   Influence of Features of Interphase Boundaries on Mechanical Properties and Fracture Pattern in Metal-Ceramic Composites [J].
Psakhie, Sergey ;
Ovcharenko, Vladimir ;
Yu, Baohai ;
Shilko, Evgeny ;
Astafurov, Sergey ;
Ivanov, Yury ;
Byeli, Alexey ;
Mokhovikov, Alexey .
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2013, 29 (11) :1025-1034
[32]   Six-year clinical performance of lithium disilicate glass-ceramic CAD-CAM versus metal-ceramic crowns [J].
Aziz, Ahmed ;
El-Mowafy, Omar .
JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (01) :44-54
[33]   Marginal fit of metal-ceramic crowns fabricated by using a casting and two selective laser melting processes before and after ceramic firing [J].
Hong, Min-Ho ;
Min, Bong Ki ;
Lee, Du-Hyeong ;
Kwon, Tae-Yub .
JOURNAL OF PROSTHETIC DENTISTRY, 2019, 122 (05) :475-481
[34]   The effect of laboratory procedures and repeated-glazing on color of metal-ceramic restoration [J].
Ozdemir, Hatice ;
Duymus, Zeynep Yesil .
CONTEMPORARY CLINICAL DENTISTRY, 2019, 10 (02) :239-242
[35]   Effect of Metal-Ceramic or All-Ceramic Superstructure Materials on Stress Distribution in a Single Implant-Supported Prosthesis: Three-Dimensional Finite Element Analysis [J].
Gomes, Erica Alves ;
Ricardo Barao, Valentim Adelino ;
Rocha, Eduardo Passos ;
de Almeida, Erika Oliveira ;
Assuncao, Wirley Goncalves .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) :1202-1209
[36]   Effect of screw-access channels on the fracture resistance of 3 types of ceramic implant-supported crowns [J].
Hussien, Ahmed Naguib M. ;
Rayyan, Mohammad M. ;
Sayed, Nagwa M. ;
Segaan, Lucette G. ;
Goodacre, Charles J. ;
Kattadiyil, Mathew T. .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 116 (02) :214-220
[37]   All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: Single crowns (SCs) [J].
Sailer, Irena ;
Makarov, Nikolay Alexandrouich ;
Thoma, Daniel Stefan ;
Zwahlen, Marcel ;
Pjetursson, Bjarni Eluar .
DENTAL MATERIALS, 2015, 31 (06) :603-623
[38]   Randomized Controlled Clinical Trial to Compare Posterior Implant-Supported Modified Monolithic Zirconia and Metal-Ceramic Single Crowns: One-Year Results [J].
Cheng, Chih-Wen ;
Chien, Chia-Hui ;
Chen, Chun-Jung ;
Papaspyridakos, Panos .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01) :15-21
[39]   Marginal Fit of Metal-Ceramic Copings: Effect of Luting Cements and Tooth Preparation Design [J].
dos Santos Paes de Almeida, Juliana Gomes ;
Guedes, Carlos Gramani ;
Abi-Rached, Filipe de Oliveira ;
Trindade, Flavia Zardo ;
Fonseca, Renata Garcia .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01) :E265-E270
[40]   Influence of firing conditions and production methods on fracture strength of titanium-based metal ceramic crowns [J].
Haag, P. ;
Khan, F. ;
Andersson, M. ;
von Steyern, P. Vult .
JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2018, 32 (03) :225-238