Effect of Palatal Metal Collar's Height on Fracture Resistance of Single Metal-Ceramic Crowns

被引:2
作者
Aburaisi, Nour [1 ]
Elbishari, Haitham [2 ]
机构
[1] Dr Sulaiman Al Habib Hosp, Restorat Dentist, Khobar, Saudi Arabia
[2] Mohammed Bin Rashid Univ Med & Hlth Sci MBRU, Hamdan Bin Mohammed Coll Dent Med HBMCDM, Dept Prosthodont, Dubai, U Arab Emirates
关键词
PORCELAIN; RESTORATIONS; STRENGTH; MARGINS; LOAD;
D O I
10.1155/2022/8290538
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The purpose of this study is to evaluate the effect of the palatal metal collar height on the fracture resistance of metal-ceramic crowns. Materials and Methods. A maxillary premolar typodont tooth was prepared and scanned to fabricate 48 metal analogs. The analogs were then scanned to fabricate metal copings divided into 4 groups according to palatal metal collar height as follows; (C0): 0 mm, (C1): 1.0 mm, (C2): 1.5 mm, and (C3): 2.0 mm. After a standard application of pressed ceramic, each crown was cemented onto its corresponding metal tooth analog. The crown-analog assembly was subjected to a sequence of thermal stressing for 5,000 cycles. A universal testing machine applied controlled loads to the crowns until fracture. Examination under a stereomicroscope determined the failure mode. A scanning electron microscope (SEM) was used to examine fracture. Load to failure data was analyzed using ANOVA followed by Tukey HSD (P & LE;0.05). Results. ANOVA statistics revealed that groups with a palatal metal collar presented significantly higher failure loads when compared to the collarless group (P < 0.0001). Difference in failure loads between 1.5-mm and 2.0-mm palatal metal collar height were not statistically significant (P=0.935). There were no significant differences detected among the groups in terms of failure mode. Conclusions. The height of the palatal metal collar has an effect on the fracture resistance of the metal-ceramic crowns. Clinical Relevance. The incorporation of a palatal collar with a predetermined height is essential to reduce the mechanical failure of metal-ceramic crowns.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] The Effect of Framework Design on Fracture Resistance of Metal-Ceramic Implant-Supported Single Crowns
    de Oliveira, Jose Luiz G.
    Martins, Leandro Moura
    Sanada, Jefesson
    de Oliveira, Pedro Cesar G.
    do Valle, Accacio L.
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 350 - 352
  • [2] The effect of finish line curvature on marginal fit of all-ceramic CAD/CAM crowns and metal-ceramic crowns
    Tao, Jianxiang
    Han, Dongwei
    [J]. QUINTESSENCE INTERNATIONAL, 2009, 40 (09): : 745 - 752
  • [3] Radiographic evaluation of the margins of clinically acceptable metal-ceramic crowns
    Badar, Sheikh Bilal
    Zafar, Kamil
    Ghafoor, Robia
    Khan, Farhan Raza
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2022, 72 (02) : S42 - S46
  • [4] Retention of metal-ceramic crowns with contemporary dental cements
    Johnson, Glen H.
    Lepe, Xavier
    Zhang, Hai
    Wataha, John C.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (09) : 1125 - 1136
  • [5] The effect of ferrule on the fracture mode of endodontically treated canines restored with fibre posts and metal-ceramic or all-ceramic crowns
    Fragou, Theodora
    Tortopidis, Dimitrios
    Kontonasaki, Eleana
    Evangelinaki, Evangelia
    Ioannidis, Konstantinos
    Petridis, Haralampos
    Koidis, Petros
    [J]. JOURNAL OF DENTISTRY, 2012, 40 (04) : 276 - 285
  • [6] Evaluation of marginal fit of single implant-supported metal-ceramic crowns prepared by using presintered metal blocks
    Pasali, Baris
    Sarac, Duygu
    Kaleli, Necati
    Sarac, Yakup Sinasi
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (02) : 257 - 262
  • [7] Survival and Chipping of Zirconia-Based and Metal-Ceramic Implant-Supported Single Crowns
    Schwarz, Stefanie
    Schroeder, Christin
    Hassel, Alexander
    Boemicke, Wolfgang
    Rammelsberg, Peter
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 : e119 - e125
  • [8] The effect of coping/veneer thickness on the fracture toughness and residual stress of implant supported, cement retained zirconia and metal-ceramic crowns
    Millen, Christopher S.
    Reuben, Robert L.
    Ibbetson, Richard J.
    [J]. DENTAL MATERIALS, 2012, 28 (10) : E250 - E258
  • [9] Comparison of fatigue resistance and failure modes between metal-ceramic and all-ceramic crowns by cyclic loading in water
    Nicolaisen, Maj H.
    Bahrami, Golnosh
    Finlay, Scott
    Isidor, Flemming
    [J]. JOURNAL OF DENTISTRY, 2014, 42 (12) : 1613 - 1620
  • [10] Strength and fracture toughness of ceramic materials for metal-ceramic prosthetic dentistry
    Ostrovoi D.Yu.
    Gogotsi G.A.
    Gorban' S.A.
    Oshkaderov S.P.
    Stepkin V.I.
    Bobokal A.N.
    [J]. Strength of Materials, 2005, 37 (3) : 323 - 330