Electrochemical stability and corrosion resistance of Ti-Mo alloys for biomedical applications

被引:249
作者
Oliveira, N. T. C. [1 ]
Guastaldi, A. C. [1 ]
机构
[1] UNESP, Inst Quim, Dept Quim Fis, Grp Biomat, BR-14801970 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Ti-Mo alloys; Corrosion resistance; Biocompatible alloys; Titanium alloys; IN-VITRO CORROSION; TITANIUM-ALLOYS; BEHAVIOR; TI-13NB-13ZR; TI-6AL-4V; WEAR; MICROSTRUCTURE; PASSIVITY; TI-50ZR; FILM;
D O I
10.1016/j.actbio.2008.07.010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrochemical behavior of pure Ti and Ti-Mo alloys (6-20 wt.% Mo) was investigated as a function of immersion time in electrolyte simulating physiological media. Open-circuit potential values indicated that all Ti-Mo alloys studied and pure Ti undergo spontaneous passivation due to spontaneously formed oxide film passivating the metallic surface, in the chloride-containing solution. It also indicated that the addition of Mo to pure Ti up to 15 wt.% seems to improve the protection characteristics of its spontaneous oxides. Electrochemical impedance spectroscopy (EIS) studies showed high impedance values for all samples, increasing with immersion time, indicating an improvement in corrosion resistance of the spontaneous oxide film. The fit obtained suggests a single passive film present on the metals' surface, improving their resistance with immersion time, presenting the highest values to Ti-15Mo alloy. Potentiodynamic polarization showed a typical valve-metal behavior, with anodic formation of barrier-type oxide films, without pitting corrosion, even in chloride-containing solution. In all cases, the passive current values were quite small, and decrease after 360 h of immersion. All these electrochemical results suggest that the Ti-15Mo alloy is a promising material for orthopedic devices, since electrochemical stability is directly associated with biocompatibility and is a necessary condition for applying a material as biomaterial. (C) 2008 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:399 / 405
页数:7
相关论文
共 30 条
[1]   STABILITY AND OPEN CIRCUIT BREAKDOWN OF THE PASSIVE OXIDE FILM ON TITANIUM [J].
BLACKWOOD, DJ ;
PETER, LM ;
WILLIAMS, DE .
ELECTROCHIMICA ACTA, 1988, 33 (08) :1143-1149
[2]   Electrochemical characterization of cast titanium alloys [J].
Cai, Z ;
Shafer, T ;
Watanabe, I ;
Nunn, ME ;
Okabe, T .
BIOMATERIALS, 2003, 24 (02) :213-218
[3]  
Czarnowska E, 1999, J MATER PROCESS TECH, V93, P190
[4]   Influence of microstructure and alloying elements on corrosion behavior of Ti-13Nb-13Zr alloy [J].
Geetha, M ;
Mudali, UK ;
Gogia, AK ;
Asokamani, R ;
Raj, B .
CORROSION SCIENCE, 2004, 46 (04) :877-892
[5]   Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications [J].
González, JEG ;
Mirza-Rosca, JC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 471 (02) :109-115
[6]   Surface reconstruction associated with α precipitation in a Ti-Mo alloy [J].
Guo, H ;
Enomoto, M .
SCRIPTA MATERIALIA, 2006, 54 (07) :1409-1413
[7]   Formation of barrier-type amorphous anodic films on Ti-Mo alloys [J].
Habazaki, H ;
Uozumi, M ;
Konno, H ;
Nagata, S ;
Shimizu, K .
SURFACE & COATINGS TECHNOLOGY, 2003, 169 :151-154
[8]   Structure and properties of cast binary Ti-Mo alloys [J].
Ho, WF ;
Ju, CP ;
Lin, JHC .
BIOMATERIALS, 1999, 20 (22) :2115-2122
[9]   The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions [J].
Khan, MA ;
Williams, RL ;
Williams, DF .
BIOMATERIALS, 1999, 20 (07) :631-637
[10]   In-vitro corrosion and wear of titanium alloys in the biological environment [J].
Khan, MA ;
Williams, RL ;
Williams, DF .
BIOMATERIALS, 1996, 17 (22) :2117-2126