Battery-triggered ultrasensitive electrochemiluminescence detection on microfluidic paper-based immunodevice based on dual-signal amplification strategy

被引:62
|
作者
Li, Weiping [1 ]
Li, Meng [1 ]
Ge, Shenguang [1 ]
Yan, Mei [2 ]
Huang, Jiadong [1 ]
Yu, Jinghua [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Shandong Univ, Key Lab Chem Sensing & Anal, Jinan 250022, Peoples R China
[2] Univ Jinan, Shandong Prov Key Lab Fluorine Chem & Chem Mat, Jinan 250022, Peoples R China
关键词
Dual-signal amplification; Battery; Electrochemiluminescence; Multiplexed immunoassay; Point-of-care; ELECTROCHEMICAL IMMUNOSENSOR; MULTIPLEXED DETECTION; IMMUNOASSAY; IMMOBILIZATION; BIOMARKERS; PLATFORM; GLUCOSE; ANTIGEN;
D O I
10.1016/j.aca.2012.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dual-signal amplification strategy for ultrasensitive electrochemiluminescence (ECL) multiplexed immunoassay on microfluidic paper-based analytical devices (mu-PADs) was demonstrated. This dual-signal amplification technique was achieved by employing graphene oxide-chitosan/gold nanoparticles (GCA) immunosensing platform and [4,4'-(2,5-dimethoxy-1,4-phenylene)bis(ethyne-2,1-diyl) dibenzoic acid] (P-acid) functionalized nanoporous silver (P-acid/NPS) signal amplification label. For further low-cost and disposable applications, battery-triggered constant-potential ECL (+1.0V for P-acid label (vs. Ag/AgCl auxiliary electrode)) was applied on this paper-based immunodevice with the aid of a home-made voltage-tunable power device, allowing the traditional electrochemical workstation to be abandoned. We found that two tumor markers could be sequentially detected in the linear ranges of 0.003-20 and 0.001-10 ngmL(-1) with the detection limits down to 1.0 and 0.8 pgmL(-1), respectively, by simply reversing the connection mode on two working electrodes. The results exhibited excellent precision and high sensitivity of such immunoassay, and it also demonstrated that this battery-triggered ECL paper-based immunodevice could provide a rapid, simple and simultaneous multiplex immunoassay with high throughput, low-cost and low detection limits for point-of-care testing. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:66 / 74
页数:9
相关论文
共 50 条
  • [1] Battery-triggered microfluidic paper-based multiplex electrochemiluminescence immunodevice based on potential-resolution strategy
    Wang, Shaowei
    Ge, Lei
    Zhang, Yan
    Song, Xianrang
    Li, Nianqiang
    Ge, Shenguang
    Yu, Jinghua
    LAB ON A CHIP, 2012, 12 (21) : 4489 - 4498
  • [2] Rechargeable battery-triggered electrochemiluminescence detection on microfluidic origami immunodevice based on two electrodes
    Wang, Shaowei
    Dai, Weijian
    Ge, Lei
    Yan, Mei
    Yu, Jinghua
    Song, Xianrang
    Ge, Shenguang
    Huang, Jiadong
    CHEMICAL COMMUNICATIONS, 2012, 48 (80) : 9971 - 9973
  • [3] A paper-based microfluidic electrochemical immunodevice integrated with amplification-by-polymerization for the ultrasensitive multiplexed detection of cancer biomarkers
    Wu, Yafeng
    Xue, Peng
    Hui, Kam M.
    Rang, Yuejun
    BIOSENSORS & BIOELECTRONICS, 2014, 52 : 180 - 187
  • [4] Highly sensitive electrochemiluminescence aptasensor based on dual-signal amplification strategy for kanamycin detection
    Cheng, Shuting
    Zhang, Hui
    Huang, Jingcheng
    Xu, Rui
    Sun, Xia
    Guo, Yemin
    SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 737
  • [5] Dual-signal amplification strategy for electrochemiluminescence sandwich biosensor for detection of thrombin
    Li, Yingjie
    Li, Yuqin
    Xu, Ning
    Pan, Jiahong
    Chen, Tufeng
    Chen, Yaowen
    Gao, Wenhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 742 - 748
  • [6] Battery-triggered open wireless electrochemiluminescence in a microfluidic cloth-based bipolar device
    Liu, Min
    Wang, Dan
    Liu, Cuiling
    Liu, Rui
    Li, Huijie
    Zhang, Chunsun
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 246 : 327 - 335
  • [7] Ultrasensitive electrochemiluminescence detection of lengthy DNA molecules based on dual signal amplification
    Liu, Fang
    Liu, Heng
    Zhang, Meng
    Yu, Jinghua
    Wang, Shaowei
    Lu, Juanjuan
    ANALYST, 2013, 138 (12) : 3463 - 3469
  • [8] Ultrasensitive sandwich RNA-aptasensor based on dual-signal amplification strategy for highly sensitive neomycin detection
    Li, Falan
    Gao, Xiaolin
    Wang, Xiaoyang
    Guo, Yemin
    Sun, Xia
    Yang, Qingqing
    Zhang, Yanyan
    FOOD CONTROL, 2022, 131
  • [9] Dual-Signal Amplification Strategy for Ultrasensitive Photoelectrochemical Immunosensing of α-Fetoprotein
    Li, Yong-Jie
    Ma, Meng-Jie
    Zhu, Jun-Jie
    ANALYTICAL CHEMISTRY, 2012, 84 (23) : 10492 - 10499
  • [10] Electrochemiluminescence Detection in Paper-Based and Other Inexpensive Microfluidic Devices
    Gross, Erin M.
    Durant, Hannah E.
    Hipp, Kenneth N.
    Lai, Rebecca Y.
    CHEMELECTROCHEM, 2017, 4 (07): : 1594 - 1603