Dissolved air flotation of surface water for spiral-wound module nanofiltration pre-treatment

被引:7
作者
Geraldes, Vitor [1 ]
Anil, Aykut [1 ]
de Pinho, Maria Norberta [1 ]
Duarte, Elizabeth [2 ]
机构
[1] Univ Tecn Lisboa, Dept Chem & Biol Engn, Inst Super Tecn, P-1049001 Lisbon, Portugal
[2] Inst Super Agron, Dept Agr & Environm Chem, P-1349017 Lisbon, Portugal
关键词
dissolved air flotation; spiral-wound module; nanofiltration; coagulation/flocculation; SDI; MFI;
D O I
10.1016/j.desal.2007.10.008
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Bench-scale dissolved air flotation (DAF) of Tagus River surface water (Valadas, Portugal) was investigated as pre-treatment for spiral-wound module nanofiltration (SWNF). Before the DAF, a coagulation/flocculation of the surface water was performed using aluminium sulphate, ferric chloride and chitosan coagulants and several commercial coagulant aids. The coagulation/flocculation experiments were carried with 2 L of surface water in a jar-test equipment at room temperature. The DAF performance to remove colloidal matter and suspended solids was evaluated through the measurement of the silt density index (SDI) and the modified fouling index (MFI) of the treated water. The air saturation pressure was varied between 300 and 600 kPa and the recycle ratio between 5 and 50%. The DAF without coagulation/flocculation was not effective in the reduction of both the SDI and MFI, even at a high DAF recycle ratio of 50%. The use of coagulants improved the DAF efficacy in reducing the fouling indexes and, for the optimal operating conditions, the MFI of the treated water was reduced by more than one order of magnitude. However, it was not possible to obtain treated water with SDI and MFI values below the recommended ones for SWNF. Further filtration of the DAF treated water with a 5 micron capsule filter was necessary to reduce the SDI below 5%/min and the MFI below 10 s/l(2). The integration of DAF with another process that removes the residual suspended solids and colloidal matter is, therefore, necessary to provide a good pretreatment for the SWNF of Tagus River surface water.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 16 条
[1]  
Boerlage SFE, 1998, DESALINATION, V118, P131
[2]   Mechanisms of colloidal natural organic matter fouling in ultrafiltration [J].
Costa, Ana Rita ;
de Pinho, Maria Norberta ;
Elimelech, Menachem .
JOURNAL OF MEMBRANE SCIENCE, 2006, 281 (1-2) :716-725
[3]   Two years of nanofiltration at the Mery-sur-Oise plant, France [J].
Cyna, B ;
Chagneau, G ;
Bablon, G ;
Tanghe, N .
DESALINATION, 2002, 147 (1-3) :69-75
[4]  
de Pinho MN, 2000, PULP PAP-CANADA, V101, P50
[5]  
DERBRUGGEN VB, 2003, ENVIRON POLLUT, V122, P435
[6]  
GERALDES V, J E WATER IN PRESS
[7]   Nanofiltration of a German groundwater of high hardness and NOM content:: performance and costs [J].
Gorenflo, A ;
Velázquez-Padrón, D ;
Frimmel, FH .
DESALINATION, 2003, 151 (03) :253-265
[8]  
Metcalf Eddy Inc., 1991, WAST ENG TREATM DISP
[9]   Removal of natural organic matter by ultrafiltration and nanofiltration for drinking water production [J].
Mijatovic, I ;
Matosic, M ;
Cerneha, BH ;
Bratulic, D .
DESALINATION, 2004, 169 (03) :223-230
[10]   Nanofiltration concentrate disposal: experiences in the Netherlands [J].
Nederlof, MM ;
van Paassen, JAM ;
Jong, R .
DESALINATION, 2005, 178 (1-3) :303-312