A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current Errors

被引:329
作者
Estima, Jorge O. [1 ,2 ]
Marques Cardoso, Antonio J. [2 ,3 ]
机构
[1] Univ Coimbra, Dept Elect & Comp Engn, P-3030290 Coimbra, Portugal
[2] Inst Telecomunicacoes, P-3030290 Coimbra, Portugal
[3] Univ Beira Interior, Dept Electromech Engn, P-6201001 Covilha, Portugal
关键词
AC motors; fault detection; fault diagnosis; fault location; machine vector control; permanent-magnet motors; pulsewidth modulation inverters; variable-speed drives; velocity control; OPEN-SWITCH FAULTS; TORQUE CONTROL; INVERTER; RELIABILITY; SCHEME; COST;
D O I
10.1109/TIE.2012.2188877
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Three-phase inverters are currently utilized in an enormous variety of industrial applications, including variable-speed ac drives. However, due to their complexity and exposure to several stresses, they are prone to suffer critical failures. Accordingly, this paper presents a novel diagnostic algorithm that allows the real-time detection and localization of multiple power switch open-circuit faults in inverter-fed ac motor drives. The proposed method is quite simple and just requires the measured motor phase currents and their corresponding reference signals, already available from the main control system, therefore avoiding the use of additional sensors and hardware. Several experimental results using a vector-controlled permanent-magnet synchronous motor drive are presented, showing the diagnostic algorithm effectiveness, its relatively fast detection time, and its robustness against false alarms.
引用
收藏
页码:3496 / 3505
页数:10
相关论文
共 32 条
[11]   A New Approach for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Source Inverters [J].
Estima, Jorge O. ;
Marques Cardoso, Antonio J. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2011, 47 (06) :2487-2494
[12]  
Freire N. M. A., 2011, 2011 8th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives (SDEMPED 2011), P397, DOI 10.1109/DEMPED.2011.6063654
[13]  
Fuchs FW, 2003, IEEE IND ELEC, P1378
[14]   Improvement of Matrix Converter Drive Reliability by Online Fault Detection and a Fault-Tolerant Switching Strategy [J].
Khiem Nguyen-Duy ;
Liu, Tian-Hua ;
Chen, Der-Fa ;
Hung, John Y. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) :244-256
[15]   Fault-Tolerant Matrix Converter Motor Drives With Fault Detection of Open Switch Faults [J].
Khwan-on, Sudarat ;
de Lillo, Liliana ;
Empringham, Lee ;
Wheeler, Pat .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (01) :257-268
[16]   Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open [J].
Kim, K. -H. ;
Gu, B. -G. ;
Jung, I. -S. .
IET ELECTRIC POWER APPLICATIONS, 2011, 5 (06) :529-539
[17]  
Kral C, 2000, IEEE POWER ELECTRON, P213, DOI 10.1109/PESC.2000.878841
[18]   A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters [J].
Lu, Bin ;
Sharma, Santosh K. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (05) :1770-1777
[19]  
Mendes AMS, 1998, IEE CONF PUBL, P538, DOI 10.1049/cp:19980607
[20]   Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's Vector approach [J].
Mendes, AMS ;
Cardoso, AJM .
IEMDC'99 - IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, PROCEEDINGS, 1999, :704-706