Reduced-order constrained optimization (ROCO): Clinical application to head-and-neck IMRT

被引:3
|
作者
Rivera, Linda [1 ]
Yorke, Ellen [2 ]
Kowalski, Alex [2 ]
Yang, Jie [2 ]
Radke, Richard J. [1 ]
Jackson, Andrew [2 ]
机构
[1] Rensselaer Polytech Inst, Troy, NY 12180 USA
[2] Mem Sloan Kettering Canc Ctr, New York, NY 10065 USA
关键词
IMRT; head-and-neck; constrained optimization; dimensionality reduction; INTENSITY-MODULATED RADIOTHERAPY; PARETO SURFACES; NAVIGATION; ALGORITHM; SYSTEM; PLANS;
D O I
10.1118/1.4788653
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The authors present the application of the reduced order constrained optimization (ROCO) method, previously successfully applied to the prostate and lung sites, to the head-and-neck (H&N) site, demonstrating that it can quickly and automatically generate clinically competitive IMRT plans. We provide guidelines for applying ROCO to larynx, oropharynx, and nasopharynx cases, and report the results of a live experiment that demonstrates how an expert planner can save several hours of trial-and-error interaction using the proposed approach. Methods: The ROCO method used for H&N IMRT planning consists of three major steps. First, the intensity space of treatment plans is sampled by solving a series of unconstrained optimization problems with a parameter range based on previously treated patient data. Second, the dominant modes in the intensity space are estimated by dimensionality reduction using principal component analysis (PCA). Third, a constrained optimization problem over this basis is quickly solved to find an IMRT plan that meets organ-at-risk (OAR) and target coverage constraints. The quality of the plan is assessed using evaluation tools within Memorial Sloan-Kettering Cancer Center (MSKCC)'s treatment planning system (TPS). Results: The authors generated ten H&N IMRT plans for previously treated patients using the ROCO method and processed them for deliverability by a dynamic multileaf collimator (DMLC). The authors quantitatively compared the ROCO plans to the previously achieved clinical plans using the TPS tools used at MSKCC, including DVH and isodose contour analysis, and concluded that the ROCO plans would be clinically acceptable. In our current implementation, ROCO H&N plans can be generated using about 1.6 h of offline computation followed by 5-15 min of semiautomatic planning time. Additionally, the authors conducted a live session for a plan designated by MSKCC performed together with an expert H&N planner. A technical assistant set up the first two steps, which were performed without further human interaction, and then collaborated in a virtual meeting with the expert planner to perform the third (constrained optimization) step. The expert planner performed in-depth analysis of the resulting ROCO plan and deemed it to be clinically acceptable and in some aspects superior to the clinical plan. This entire process took 135 min including two constrained optimization runs, in comparison to the estimated 4 h that would have been required using traditional clinical planning tools. Conclusions: The H&N site is very challenging for IMRT planning, due to several levels of prescription and a large, variable number (6-20) of OARs that depend on the location of the tumor. ROCO for H&N shows promise in generating clinically acceptable plans both more quickly and with substantially less human interaction. (c) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4788653]
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Reduced order constrained optimization (ROCO): Clinical application to lung IMRT
    Stabenau, Hans
    Rivera, Linda
    Yorke, Ellen
    Yang, Jie
    Lu, Renzhi
    Radke, Richard J.
    Jackson, Andrew
    MEDICAL PHYSICS, 2011, 38 (05) : 2731 - 2741
  • [2] Clinical evaluation of direct aperture optimization when applied to head-and-neck IMRT
    Jones, Stephen
    Williams, Matthew
    MEDICAL DOSIMETRY, 2008, 33 (01) : 86 - 92
  • [3] Adequate margins for random setup uncertainties in head-and-neck IMRT
    Astreinidou, E
    Bel, A
    Raaijmakers, CPJ
    Terhaard, CHJ
    Lagendijk, JJW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 938 - 944
  • [4] Impact of MLC properties and IMRT technique in meningioma and head-and-neck treatments
    Kantz, Steffi
    Soehn, Matthias
    Troeller, Almut
    Reiner, Michael
    Weingandt, Helmut
    Alber, Markus
    Belka, Claus
    Ganswindt, Ute
    RADIATION ONCOLOGY, 2015, 10
  • [5] DOSIMETRIC EVALUATION OF AUTOMATIC SEGMENTATION FOR ADAPTIVE IMRT FOR HEAD-AND-NECK CANCER
    Tsuji, Stuart Y.
    Hwang, Andrew
    Weinberg, Vivian
    Yom, Sue S.
    Quivey, Jeanne M.
    Xia, Ping
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 77 (03): : 707 - 714
  • [6] IMRT: preliminary results in a series of advanced head-and-neck cancer patients
    Vila Capel, Antonio
    Vilar Palop, Jorge
    Pedro Olive, Agustin
    Sanchez-Reyes Fernandez, Alberto
    Vayreda Ribera, Jordi
    Julia Sanahuja, Joan Carles
    de Olaguer Agustin, Joaquim Perez
    Artola Codina, Nuria
    Moya Cascant, Luis Miguel
    Rubio Calatayud, Esther
    Carrera Domenech, Gemma
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2013, 15 (03): : 233 - 242
  • [7] Gradient-based constrained optimization using a database of linear reduced-order models
    Choi, Youngsoo
    Boncoraglio, Gabriele
    Anderson, Spenser
    Amsallem, David
    Farhat, Charbel
    JOURNAL OF COMPUTATIONAL PHYSICS, 2020, 423 (423)
  • [8] Heterogeneity in head and neck IMRT target design and clinical practice
    Hong, Theodore S.
    Tome, Wolfgang A.
    Harari, Paul M.
    RADIOTHERAPY AND ONCOLOGY, 2012, 103 (01) : 92 - 98
  • [9] Is there a "mucosa-sparing" benefit of IMRT for head-and-neck cancer?
    Sanguineti, Giuseppe
    Endres, Eugene J.
    Gunn, Brandon G.
    Parker, Brent
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : 931 - 938
  • [10] Dose variations in tumor volumes and organs at risk during IMRT for head-and-neck cancer
    Beltran, Merce
    Ramos, Monica
    Jose Rovira, Juan
    Perez-Hoyos, Santiago
    Sancho, Marc
    Puertas, Enrique
    Benavente, Sergi
    Ginjaume, Merce
    Giralt, Jordi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 101 - 111