Critical evaluation of connectivity-based point of care testing systems of glucose in a hospital environment

被引:11
作者
Flore, Katelijne M. J. [1 ]
Fiers, Tom [1 ]
Delanghe, Joris R. [1 ]
机构
[1] Ghent Univ Hosp, Clin Chem Lab, B-9000 Ghent, Belgium
关键词
critically ill patients; hyperglycemia; point of care testing (POCT); quality control; tight glucose monitoring;
D O I
10.1515/CCLM.2008.332
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: In recent years a number of point of care testing (POCT) glucometers were introduced on the market. We investigated the analytical variability (lot-to-lot variation, calibration error, inter-instrument and inter-operator variability) of glucose POCT systems in a university hospital environment and compared these results with the analytical needs required for tight glucose monitoring. Methods: The reference hexokinase method was compared to different POCT systems based on glucose oxidase (blood gas instruments) or glucose dehydrogenase (handheld glucometers). Based upon daily internal quality control data, total errors were calculated for the various glucose methods and the analytical variability of the glucometers was estimated. Results: The total error of the glucometers exceeded by far the desirable analytical specifications (based on a biological variability model). Lot-to-lot variation, inter-instrument variation and inter-operator variability contributed approximately equally to total variance. As in a hospital environment, distribution of hematocrit values is broad, converting blood glucose into plasma values using a fixed factor further increases variance. The percentage of outliers exceeded the ISO 15197 criteria in a broad glucose concentration range. Conclusions: Total analytical variation of handheld glucometers is larger than expected. Clinicians should be aware that the variability of glucose measurements obtained by blood gas instruments is lower than results obtained with handheld glucometers on capillary blood. Clin Chem Lab Med 2008; 46: 1763-8.
引用
收藏
页码:1763 / 1768
页数:6
相关论文
共 50 条
  • [31] Clinical utility of point-of-care glucose testing in the assessment of gestational diabetes: Prospective cohort study
    Al-Hasani, Wiaam
    Ranasinghe, Ruvini
    Rogers, Helen
    Spanier, William
    Spears, Katie
    Gayle, Carol
    Long, Lisa
    Dimitriadis, Georgios K.
    Hunt, Katharine F.
    Vincent, Royce P.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2024, 131 (09) : 1270 - 1278
  • [32] A quality systems approach for identifying and controlling sources of error with point of care testing devices
    Ehrmeyer, SS
    Laessig, RH
    ACCREDITATION AND QUALITY ASSURANCE, 2002, 7 (11) : 450 - 454
  • [33] A quality systems approach for identifying and controlling sources of error with point of care testing devices
    S. S. Ehrmeyer
    Ronald H. Laessig
    Accreditation and Quality Assurance, 2002, 7 : 450 - 454
  • [34] Evaluation of the appropriateness of using a continuous glucose monitoring system and a point-of-care glucometer for measuring blood glucose in horses
    Grob, Anne J.
    Delarocque, Julien
    Feige, Karsten
    Warnken, Tobias
    PFERDEHEILKUNDE, 2024, 40 (02): : 115 - 128
  • [35] Is there a suitable point-of-care glucose meter for tight glycemic control? Evaluation of one home-use and four hospital-use meters in an intensive care unit
    Gijzen, Karlijn
    Moolenaar, David L. J.
    Weusten, Jos J. A. M.
    Pluim, Hendrik J.
    Demir, Ayse Y.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (11) : 1985 - 1992
  • [36] Paper-Based Electrochemical Biosensors for Point-of-Care Testing of Neurotransmitters
    Yingchun Li
    Rongyan He
    Yan Niu
    Fei Li
    Journal of Analysis and Testing, 2019, 3 : 19 - 36
  • [37] Paper-Based Electrochemical Biosensors for Point-of-Care Testing of Neurotransmitters
    Li, Yingchun
    He, Rongyan
    Niu, Yan
    Li, Fei
    JOURNAL OF ANALYSIS AND TESTING, 2019, 3 (01) : 19 - 36
  • [38] A Prospective Evaluation of Point-of-Care Measurements of Maternal Glucose for the Diagnosis of Gestational Diabetes Mellitus
    O'Malley, Eimer G.
    Reynolds, Ciara M. E.
    O'Kelly, Ruth
    Killalea, Anne
    Sheehan, Sharon R.
    Turner, Michael J.
    CLINICAL CHEMISTRY, 2020, 66 (02) : 316 - 323
  • [39] Two site evaluation of the performance of a new generation point-of-care glucose meter for use in a neonatal intensive care unit
    Tendl, Kristina A.
    Christoph, Juergen
    Bohn, Adele
    Herkner, Kurt R.
    Pollak, Arnold
    Prusa, Andrea-Romana
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2013, 51 (09) : 1747 - 1754
  • [40] A Hydrogel Microneedle Patch for Point-of-Care Testing Based on Skin Interstitial Fluid
    He, Rongyan
    Niu, Yan
    Li, Zedong
    Li, Ang
    Yang, Huayuan
    Xu, Feng
    Li, Fei
    ADVANCED HEALTHCARE MATERIALS, 2020, 9 (04)