Experience With an On-Site Coronary Computed Tomography-Derived Fractional Flow Reserve Algorithm for the Assessment of Intermediate Coronary Stenoses

被引:45
作者
Donnelly, Patrick M. [1 ]
Kolossvary, Marton [2 ]
Karady, Julia [2 ]
Ball, Peter A. [1 ]
Kelly, Stephanie [1 ]
Fitzsimons, Donna [1 ]
Spence, Mark S. [1 ]
Celeng, Csilla [2 ]
Horvath, Tamas [3 ]
Szilveszter, Balint [2 ]
van Es, Hendrik W. [4 ]
Swaans, Martin J. [4 ]
Merkely, Bela [2 ]
Maurovich-Horvat, Pal [2 ]
机构
[1] Ulster Univ, Cardiovasc Imaging & Res Dept, Ulster Hosp, South Eastern Hlth & Social Care Trust, Belfast, Antrim, North Ireland
[2] Semmelweis Univ, Heart & Vasc Ctr, MTA SE Cardiovasc Imaging Res Grp CIRG, Budapest, Hungary
[3] Budapest Univ Technol & Econ, Fac Mech Engn, Dept Hydrodynam Syst, Budapest, Hungary
[4] St Antonius Hosp, Dept Radiol, Nieuwegein, Netherlands
关键词
CT ANGIOGRAPHY; HEMODYNAMIC SIGNIFICANCE; DIAGNOSTIC PERFORMANCE; LESIONS; TRIAL;
D O I
10.1016/j.amjcard.2017.09.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fractional flow reserve (FFR) derived from coronary computed tomography angiography (CTA) is a new technique for the diagnosis of ischemic coronary artery stenoses. The aim of this prospective study was to evaluate the diagnostic performance of a novel on-site computed tomography-based fractional flow reserve algorithm (CT-FFR) compared with invasive FFR as the gold standard, and to determine whether its diagnostic performance is affected by interobserver variations in lumen segmentation. We enrolled 44 consecutive patients (64.6 +/- 8.9 years, 34% female) with 60 coronary atherosclerotic lesions who underwent coronary CTA and invasive coronary angiography in 2 centers. An FFR value <= 0.8 was considered significant. Coronary CTA scans were evaluated by 2 expert readers, who manually adjusted the semiautomated coronary lumen segmentations for effective diameter stenosis (EDS) assessment and on-site CT-FFR simulation. The mean CT-FFR value was 0.77 +/- 0.15, whereas the mean EDS was 43.6 +/- 16.9%. The sensitivity, specificity, positive predictive value, and negative predictive value of CT-FFR versus EDS with a cutoff of 50% were the following: 91%, 72%, 63%, and 93% versus 52%, 87%, 69%, and 77%, respectively. The on-site CT-FFR demonstrated significantly better diagnostic performance compared with EDS (area under the curve 0.89 vs 0.74, respectively, p <0.001). The CT-FFR areas under the curve of the 2 readers did not show any significant difference (0.89 vs 0.88, p = 0.74). In conclusion, on-site CT-FFR simulation is feasible and has better diagnostic performance than anatomic stenosis assessment. Furthermore, the diagnostic performance of the on-site CT-FFR simulation algorithm does not depend on the readers' semiautomated lumen segmentation adjustments. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:9 / 13
页数:5
相关论文
共 29 条
[1]  
Administration UFaD, 2014, FDA ALL MARK NON DEV
[2]  
Altman D.G., 1991, Practical Statistics for Medical Research
[3]   Fractional flow reserve: Critical review of an important physiologic adjunct to angiography [J].
Bishop, AH ;
Samady, H .
AMERICAN HEART JOURNAL, 2004, 147 (05) :792-802
[4]   CT Angiography for the Prediction of Hemodynamic Significance in Intermediate and Severe Lesions Head-to-Head Comparison With Quantitative Coronary Angiography Using Fractional Flow Reserve as the Reference Standard [J].
Budoff, Matthew J. ;
Nakazato, Ryo ;
Mancini, G. B. John ;
Gransar, Heidi ;
Leipsic, Jonathon ;
Berman, Daniel S. ;
Min, James K. .
JACC-CARDIOVASCULAR IMAGING, 2016, 9 (05) :559-564
[5]   Fractional Flow Reserve Computed from Noninvasive CT Angiography Data: Diagnostic Performance of an On-Site Clinician-operated Computational Fluid Dynamics Algorithm [J].
Coenen, Adriaan ;
Lubbers, Marisa M. ;
Kurata, Akira ;
Kono, Atsushi ;
Dedic, Admir ;
Chelu, Raluca G. ;
Dijkshoorn, Marcel L. ;
Gijsen, Frank J. ;
Ouhlous, Mohamed ;
van Geuns, Robert-Jan M. ;
Nieman, Koen .
RADIOLOGY, 2015, 274 (03) :674-683
[6]   Software-based on-site estimation of fractional flow reserve using standard coronary CT angiography data [J].
De Geer, Jakob ;
Sandstedt, Marten ;
Bjorkholm, Anders ;
Alfredsson, Joakim ;
Janzon, Magnus ;
Engvall, Jan ;
Persson, Anders .
ACTA RADIOLOGICA, 2016, 57 (10) :1186-1192
[7]   Clinical outcomes of fractional flow reserve by computed tomographic angiography-guided diagnostic strategies vs. usual care in patients with suspected coronary artery disease: the prospective longitudinal trial of FFRCT: outcome and resource impacts study [J].
Douglas, Pamela S. ;
Pontone, Gianluca ;
Hlatky, Mark A. ;
Patel, Manesh R. ;
Norgaard, Bjarne L. ;
Byrne, Robert A. ;
Curzen, Nick ;
Purcell, Ian ;
Gutberlet, Matthias ;
Rioufol, Gilles ;
Hink, Ulrich ;
Schuchlenz, Herwig Walter ;
Feuchtner, Gudrun ;
Gilard, Martine ;
Andreini, Daniele ;
Jensen, Jesper M. ;
Hadamitzky, Martin ;
Chiswell, Karen ;
Cyr, Derek ;
Wilk, Alan ;
Wang, Furong ;
Rogers, Campbell ;
De Bruyne, Bernard .
EUROPEAN HEART JOURNAL, 2015, 36 (47) :3359-3367
[8]  
Freiman M, 2016, SPIE P, V9784
[9]   Improving CCTA-based lesions' hemodynamic significance assessment by accounting for partial volume modeling in automatic coronary lumen segmentation [J].
Freiman, Moti ;
Nickisch, Hannes ;
Prevrhal, Sven ;
Schmitt, Holger ;
Vembar, Mani ;
Maurovich-Horvat, Pal ;
Donnelly, Patrick ;
Goshen, Liran .
MEDICAL PHYSICS, 2017, 44 (03) :1040-1049
[10]   Quality-of-Life and Economic Outcomes of Assessing Fractional Flow Reserve With Computed Tomography Angiography PLATFORM [J].
Hlatky, Mark A. ;
De Bruyne, Bernard ;
Pontone, Gianluca ;
Patel, Manesh R. ;
Norgaard, Bjarne L. ;
Byrne, Robert A. ;
Curzen, Nick ;
Purcell, Ian ;
Gutberlet, Matthias ;
Rioufol, Gilles ;
Hink, Ulrich ;
Schuchlenz, Herwig Walter ;
Feuchtner, Gudrun ;
Gilard, Martine ;
Andreini, Daniele ;
Jensen, Jesper M. ;
Hadamitzky, Martin ;
Wilk, Alan ;
Wang, Furong ;
Rogers, Campbell ;
Douglas, Pamela S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) :2315-2323