Multi-Detector Computed Tomography Venography in the assessment of dysfunction of tunneled hemodialysis central vein catheters

被引:8
作者
Cui, Tianlei [1 ]
Li, Zhenlin [2 ]
Yang, Yingying [1 ]
Zeng, Xiaoxi [1 ]
Zhou, Li [1 ]
Jin, Lizhu [1 ]
Su, Baihai [1 ]
Tao, Ye [1 ]
Fu, Ping [1 ]
机构
[1] Sichuan Univ, Dept Nephrol, W China Hosp, Chengdu 610041, Sichuan Provinc, Peoples R China
[2] Sichuan Univ, Dept Radiol, W China Hosp, Chengdu 610041, Sichuan Provinc, Peoples R China
关键词
Catheter dysfunction; Hemodialysis; Multi-detector CT venography; Tunneled central venous catheter; DEEP VENOUS THROMBOSIS; SUSPECTED PULMONARY-EMBOLISM; SPIRAL CT VENOGRAPHY; DIAGNOSTIC-VALUE; MANAGEMENT;
D O I
10.5301/jva.5000067
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: To assess the value of Multi-Detector Computed Tomography Venography (MDCTV) in the assessment of tunneled hemodialysis central vein catheters (CVCs) dysfunction. Methods: Twenty-five patients who had tunneled CVC dysfunction without abnormality found by x-ray and ultrasound were enrolled. Anti-platelet agents, anticoagulants, and thrombolytic therapy with urokinase failed to resume normal catheter function. MDCTV was performed to observe the position of catheters and to detect central venous stenosis, thrombosis, and fibrin sheath formation. Correct intervention was given according to MDCTV results. Results: MDCTV revealed that the catheter was malpositioned in 10 cases; there were five cases of central venous stenosis, four cases of central venous thrombosis, one case of fibrin sheath formation, and the other five had no abnormalities found. Blood flow on hemodialysis had reached over 300 mL/min after correct intervention. Conclusions: MDCTV provided a new possible way to assess dysfunction of tunneled hemodialysis central venous catheters.
引用
收藏
页码:388 / 392
页数:5
相关论文
共 23 条
[1]   The natural history of tunneled hemodialysis catheters removed or exchanged: A single-institution experience [J].
Alomari, Ahmad I. ;
Falk, Abigail .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (02) :227-235
[2]   Deep venous thrombosis of the lower extremity efficacy of spiral CT venography compared with conventional venography in diagnosis [J].
Baldt, MM ;
Zontsich, T ;
Stumptlen, A ;
Fleischmann, D ;
Schneider, B ;
Minar, E ;
Mostbeck, GH .
RADIOLOGY, 1996, 200 (02) :423-428
[3]   Evaluation of the deep venous system in patients with suspected pulmonary embolism with multi-detector CT: A prospective study in comparison to Doppler sonography [J].
Begemann, PGC ;
Bonacker, M ;
Kemper, J ;
Guthoff, AE ;
Hahn, KE ;
Steiner, P ;
Adam, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (03) :399-409
[4]   Failing hemodialysis arteriovenous fistula and percutaneous treatment: Imaging with CT, MRI and digital subtraction angiography [J].
Cavagna, E ;
D'Andrea, P ;
Schiavon, F ;
Tarroni, G .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (04) :262-265
[5]   Deep venous thrombosis: Detection by using indirect CT venography [J].
Cham, MD ;
Yankelevitz, DF ;
Shaham, D ;
Shah, AA ;
Sherman, L ;
Lewis, A ;
Rademaker, J ;
Pearson, G ;
Choi, JS ;
Wolff, W ;
Prabhu, PM ;
Galanski, M ;
Clark, RA ;
Sostman, HD ;
Henschke, CI .
RADIOLOGY, 2000, 216 (03) :744-751
[6]   Hemodialysis Central Venous Catheter Dysfunction [J].
Chan, Micah R. .
SEMINARS IN DIALYSIS, 2008, 21 (06) :516-521
[7]   Vascular access use and outcomes: an international perspective from the dialysis outcomes and practice patterns study [J].
Ethier, Jean ;
Mendelssohn, David C. ;
Elder, Stacey J. ;
Hasegawa, Takeshi ;
Akizawa, Tadao ;
Akiba, Takashi ;
Canaud, Bernard J. ;
Pisoni, Ronald L. .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (10) :3219-3226
[8]   Malfunction of Dialysis Catheters: Management of Fibrin Sheath and Related Problems [J].
Faintuch, Salao ;
Salazar, G. M. M. .
TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 11 (03) :195-200
[9]   THE DIAGNOSTIC-VALUE OF COLOR DOPPLER ULTRASOUND IN CENTRAL VENOUS CATHETER-RELATED THROMBOSIS [J].
KOKSOY, C ;
KUZU, A ;
KUTLAY, J ;
ERDEN, I ;
OZCAN, H ;
ERGIN, K .
CLINICAL RADIOLOGY, 1995, 50 (10) :687-689
[10]   Tunneled catheters in hemodialysis patients: Reasons and subsequent outcomes [J].
Lee, T ;
Barker, J ;
Allon, M .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2005, 46 (03) :501-508