Impingement in total hip replacement: mechanisms and consequences

被引:43
作者
Brown, Thomas D. [1 ,2 ]
Callaghan, John J. [1 ,2 ,3 ]
机构
[1] Univ Iowa, Dept Orthopaed & Rehabil, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Biomed Engn, Iowa City, IA 52242 USA
[3] Vet Adm Hosp, Iowa City, IA 52242 USA
来源
CURRENT ORTHOPAEDICS | 2008年 / 22卷 / 06期
关键词
Impingement; Dislocation; Total hip; Finite element analysis; Capsule;
D O I
10.1016/j.cuor.2008.10.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The occurrence of total hip impingement, whether or not accompanied by frank dislocation, holds substantial untoward clinical. consequences, especially as less-forgiving advanced bearing implant designs come into ever more widespread use. Biomechanical aspects of impingement and dislocation have historically received relatively little scientific attention, although that situation is now rapidly changing. The present article reviews contemporary laboratory and clinical. research on the impingement/dislocation phenomena, focusing particularly on how implant design variables, surgical implantation factors and patient activity each act individually and in concert to pose impingement and dislocation challenges. In recent years, several powerful. new research methodologies have emerged that have greatly expanded the scope for clinical translation of systematic laboratory study. Transferring the findings from such research into yet better implant designs, and even better surgical procedures, offers encouragement that the clinical impact of this troublesome complication can be further reduced. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:376 / 391
页数:16
相关论文
共 48 条
[1]  
AMSTUTZ HC, 1975, CLIN ORTHOP RELAT R, P124
[2]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[3]   Concerns about ceramics in THA [J].
Barrack, RL ;
Barak, C ;
Skinner, HB .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :73-79
[4]   Metal-on-metal surface arthroplasty with a cemented femoral component -: A 7-10 year follow-up study [J].
Beaulé, PE ;
Le Duff, M ;
Campbell, P ;
Dorey, FJ ;
Park, SH ;
Amstutz, HC .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :17-22
[5]  
BOZIC KJ, 2008, T 54 ORS SAN FRANC C, V235
[6]   Fatigue crack propagation resistance of highly crosslinked polyethylene [J].
Bradford, L ;
Baker, D ;
Ries, MD ;
Pruitt, LA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :68-72
[7]  
CHANDLER DR, 1982, CLIN ORTHOP RELAT R, P284
[9]   Changing demographics of patients with total joint replacement [J].
Crowninshield, Roy D. ;
Rosenberg, Aaron G. ;
Sporer, Scott M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (443) :266-272
[10]   OPERATIVE CORRECTION OF AN UNSTABLE TOTAL HIP-ARTHROPLASTY [J].
DALY, PJ ;
MORREY, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (09) :1334-1343