Evaluation of the safety and efficiency of novel metallic ultrasonic scaler tip on titanium surfaces

被引:15
作者
Baek, Seung-Ho [1 ,2 ]
Shon, Won-Jun [1 ,2 ]
Bae, Kwang-Shik [1 ,2 ]
Kum, Kee-Yeon [1 ,2 ]
Lee, Woo-Cheol [1 ,2 ]
Park, Young-Seok [1 ,3 ]
机构
[1] Seoul Natl Univ, Dent Res Inst, Seoul 110749, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Conservat Dent, Seoul 110749, South Korea
[3] Seoul Natl Univ, Dept Oral Anat, Sch Dent, Seoul 110749, South Korea
关键词
maintenance therapy; novel ultrasonic scaler tip; surface roughness implant failures; BIOFILM FORMATION; ANTIMICROBIAL THERAPY; PERI-IMPLANTITIS; DENTAL IMPLANTS; IN-VITRO; PLAQUE; MICROBIOLOGY; COLONIZATION; DELIVERY; ENERGY;
D O I
10.1111/j.1600-0501.2011.02302.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate the safety and efficiency of novel ultrasonic scaler tips, conventional stainless-steel tips, and plastic tips on titanium surfaces. Material and methods Mechanical instrumentation was carried out using conventional ultrasonic scalers (EMS, Nyon, Switzerland) with novel metallic implant tip (BS), a plastic-headed tip (ES), a plastic tip (PS) and a conventional stainless-steel tip (CS) on 10 polished commercially pure titanium disks (Grade II) per group. Arithmetic mean roughness (Ra) and maximum height roughness (Ry) of titanium samples were measured and dissipated power of the scaler tip in the tip-surface junction was estimated to investigate the scaling efficiency. The instrumented surface morphology of samples was viewed with a scanning electron microscope (SEM) and surface profile of the each sample was investigated using contact mode with a commercial atomic force microscope (AFM). Results There were no significant differences in surface roughness (Ra and Ry) among BS, ES, and PS group. However, CS group showed significant higher surface roughness (Ra and Ry). The efficiency of CS tip is twice as much higher than that of BS tip, the efficiency of BS tip is 20 times higher than that of PS tip, and the efficiency of BS tip is 90 times higher than that of ES tip. Conclusion Novel metallic copper alloy ultrasonic scaler tips may minimally influence the titanium surface, similar to plastic tip. Therefore, they can be a suitable instrument for implant maintenance therapy.
引用
收藏
页码:1269 / 1274
页数:6
相关论文
共 33 条
  • [1] Histopathological observations of human periimplantitis lesions
    Berglundh, T
    Gislason, Ö
    Lekholm, U
    Sennerby, L
    Lindhe, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2004, 31 (05) : 341 - 347
  • [2] In vivo and in vitro biofilm formation on two different titanium implant surfaces
    Buergers, Ralf
    Gerlach, Till
    Hahnel, Sebastian
    Schwarz, Frank
    Handel, Gerhard
    Gosau, Martin
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) : 156 - 164
  • [3] A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY
    CLEVELAND, JP
    MANNE, S
    BOCEK, D
    HANSMA, PK
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) : 403 - 405
  • [4] Energy dissipation in tapping-mode atomic force microscopy
    Cleveland, JP
    Anczykowski, B
    Schmid, AE
    Elings, VB
    [J]. APPLIED PHYSICS LETTERS, 1998, 72 (20) : 2613 - 2615
  • [5] Evaluation of cutting efficiency of orthograde ultrasonic tips by using a nonstatic model
    Dentkos, Terence R.
    Berzins, David W.
    [J]. JOURNAL OF ENDODONTICS, 2008, 34 (07) : 863 - 865
  • [6] Elter C, 2008, INT J ORAL MAX IMPL, V23, P327
  • [7] Ericsson I, 1992, Clin Oral Implants Res, V3, P99, DOI 10.1034/j.1600-0501.1992.030301.x
  • [8] Bacterial colonization immediately after installation on oral titanium implants
    Fuerst, Mirjam M.
    Salvi, Giovanni E.
    Lang, Niklaus P.
    Persson, G. Rutger
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) : 501 - 508
  • [9] Gildenhuys R R, 1975, Dent Surv, V51, P56
  • [10] Immunohistochemical characteristics of inflammatory lesions at implants
    Gualini, F
    Berglundh, T
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2003, 30 (01) : 14 - 18