A rapid and reliable method for the quantitation of hydroxychloroquine in serum using turbulent flow liquid chromatography-tandem mass spectrometry

被引:40
作者
Fuezery, Anna K. [1 ]
Breaud, Autumn R. [1 ]
Emezienna, Nkechinyere [1 ]
Schools, Sabitha [1 ]
Clarke, William A. [1 ]
机构
[1] Johns Hopkins Univ, Dept Pathol, Baltimore, MD 21287 USA
关键词
Hydroxychloroquine; Serum; Turbulent flow liquid chromatography; Mass spectrometry; SYSTEMIC-LUPUS-ERYTHEMATOSUS; LOW BLOOD-CONCENTRATION; RHEUMATOID-ARTHRITIS; MAJOR METABOLITES; HEALTHY-VOLUNTEERS; BIOLOGICAL-FLUIDS; STATIONARY PHASE; HUMAN-PLASMA; DESETHYLCHLOROQUINE; CHLOROQUINE;
D O I
10.1016/j.cca.2013.02.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Hydroxychloroquine is routinely used in managing systemic lupus erythematosus and rheumatoid arthritis. Whole blood levels are currently measured in the laboratory but at least one study suggests that serum levels may be equally useful. Moreover; serum samples are the preferred matrix type in the clinical laboratory as a result of their reduced complexity compared to whole blood. These observations suggest that the clinical utility of serum hydroxychloroquine levels needs to be reevaluated using larger studies and more robust assays. We report a turbulent flow LC-MS/MS method we developed for this purpose. Methods: After protein precipitation from serum with 033 mol/l perchloric acid, hydroxychloroquine and its deuterated analog were injected onto a Cyclone turbulent flow column for sample cleanup. Analytical separation was accomplished on a HypersilGold C8 column with a gradient of water and methanol, each containing 0.1% formic acid and 10 mmol/l ammonium formate. Analytes were ionized and detected by electrospray ionization mass spectrometry with multiple reaction monitoring. Results: Our method was linear from 15.7 to 2000 ng/ml. Total imprecision at multiple levels was <5% and accuracy was within +/- 15%. The method showed minimal carryover. Our extraction efficiency was 103% and the matrix factor was 101%. Comparison with a reference laboratory method identified constant bias but good correlation between the 2 methods. Conclusions: We present a novel turbulent flow liquid chromatography-tandem mass spectrometry method for quantification of hydroxychloroquine in serum. Our method has comparable sensitivity, selectivity, precision, accuracy, and linearity to previously reported methods. However, it offers simpler sample processing, shorter overall analysis time, and minimal carryover. These characteristics make our method well-suited for efficient analysis of the large number of samples necessary for studies on the clinical utility of serum HQ levels. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 84
页数:6
相关论文
共 22 条
[1]   Hydroxychloroquine: From Malaria to Autoimmunity [J].
Ben-Zvi, Ilan ;
Kivity, Shaye ;
Langevitz, Pnina ;
Shoenfeld, Yehuda .
CLINICAL REVIEWS IN ALLERGY & IMMUNOLOGY, 2012, 42 (02) :145-153
[2]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR HYDROXYCHLOROQUINE AND 3 OF ITS MAJOR METABOLITES, DESETHYLHYDROXYCHLOROQUINE, DESETHYLCHLOROQUINE AND BIDESETHYLCHLOROQUINE, IN HUMAN-PLASMA [J].
BROWN, RR ;
STROSHANE, RM ;
BENZIGER, DP .
JOURNAL OF CHROMATOGRAPHY, 1986, 377 :454-459
[3]   Very low blood hydroxychloroquine concentration as an objective marker of poor adherence to treatment of systemic lupus erythematosus [J].
Costedoat-Chalumeau, Nathalie ;
Amoura, Zahir ;
Hulot, Jean-Sebastien ;
Aymard, Guy ;
Leroux, Gaelle ;
Marra, Donata ;
Lechat, Philippe ;
Piette, Jean-Charles .
ANNALS OF THE RHEUMATIC DISEASES, 2007, 66 (06) :821-824
[4]   Low blood concentration of hydroxychloroquine is a marker for and predictor of disease exacerbations in patients with systemic lupus erythematosus [J].
Costedoat-Chalumeau, Nathalie ;
Amoura, Zahir ;
Hulot, Jean-Sebastien ;
Abou Hammoud, Hala ;
Aymard, Guy ;
Cacoub, Patrice ;
Frances, Camille ;
Wechsler, Bertrand ;
Huong, Du Le Thi ;
Ghillani, Pascale ;
Musset, Lucile ;
Lechat, Philippe ;
Piette, Jean-Charles .
ARTHRITIS AND RHEUMATISM, 2006, 54 (10) :3284-3290
[5]   SIMPLE AND RAPID HPLC OF QUININE, HYDROXYCHLOROQUINE, CHLOROQUINE, AND DESETHYLCHLOROQUINE IN SERUM, WHOLE-BLOOD, AND FILTER PAPER-ADSORBED DRY BLOOD [J].
CROES, K ;
MCCARTHY, PT ;
FLANAGAN, RJ .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (05) :255-260
[6]   ENANTIOSELECTIVE DETERMINATION OF HYDROXYCHLOROQUINE AND ITS MAJOR METABOLITES IN URINE AND THE OBSERVATION OF A REVERSAL IN THE (+)-(-)-HYDROXYCHLOROQUINE RATIO [J].
FIEGER, H ;
IREDALE, J ;
WAINER, IW .
CHIRALITY, 1993, 5 (02) :65-70
[7]  
Francès C, 2012, ARCH DERMATOL, V148, P479, DOI 10.1001/archdermatol.2011.2558
[8]   DETERMINATION OF HYDROXYCHLOROQUINE AND ITS MAJOR METABOLITES IN PLASMA USING SEQUENTIAL ACHIRAL CHIRAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
IREDALE, J ;
WAINER, IW .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 573 (02) :253-258
[9]   DOSAGE OF ANTIMALARIAL DRUGS FOR CHILDREN WITH JUVENILE RHEUMATOID ARTHRITIS AND SYSTEMIC LUPUS ERYTHEMATOSUS - CLINICAL STUDY WITH DETERMINATION OF SERUM CONCENTRATIONS OF CHLOROQUINE AND HYDROXYCHLOROQUINE [J].
LAAKSONEN, AL ;
KOSKIAHDE, V ;
JUVA, K .
SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 1974, 3 (02) :103-108
[10]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889