Magnetic resonance imaging for stroke: Basis principles and clinical use.

被引:33
作者
Heiland, S [1 ]
Sartor, K [1 ]
机构
[1] Univ Heidelberg Klinikum, Abt Neuroradiol, D-69120 Heidelberg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 171卷 / 01期
关键词
cerebral ischemia; perfusion-MRI; diffusion-MRI; MR angiography;
D O I
10.1055/s-1999-9889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Stroke is the third leading cause of death. Until recently, no diagnostic technique was available that could reliably depict ischemic tissue within a therapeutically promising time window. Since the beginning of this decade, a fundamental change has taken place: Perfusion- and diffusion-MRI have shown to be capable of depicting the ischemic injury immediately after vessel occlusion. While perfusion MRI is sensitive to abnormalities in cerebral capillary blood flow (micro-circulation), diffusion MRI indicates tissue damage on a cellular level. Combining perfusion- and diffusion-MRI with standard MR techniques (T-2-weighted sequences, MR angiography) results in an MR protocol that is complementary and gives insight into both structural and functional parameters.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 51 条
  • [1] THRESHOLDS IN CEREBRAL-ISCHEMIA - THE ISCHEMIC PENUMBRA
    ASTRUP, J
    SIESJO, BK
    SYMON, L
    [J]. STROKE, 1981, 12 (06) : 723 - 725
  • [3] Enlargement of human cerebral ischemic lesion volumes measured by diffusion-weighted magnetic resonance imaging
    Baird, AE
    Benfield, A
    Schlaug, G
    Siewert, B
    Lovblad, KO
    Edelman, RR
    Warach, S
    [J]. ANNALS OF NEUROLOGY, 1997, 41 (05) : 581 - 589
  • [4] BENFIELD Y, 1996, ISMRM 4 SCI M BOOK A, V4, P1344
  • [5] Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise
    Benner, T
    Heiland, S
    Erb, G
    Forsting, M
    Sartor, K
    [J]. MAGNETIC RESONANCE IMAGING, 1997, 15 (03) : 307 - 317
  • [6] MECHANISM OF DETECTION OF ACUTE CEREBRAL-ISCHEMIA IN RATS BY DIFFUSION-WEIGHTED MAGNETIC-RESONANCE MICROSCOPY
    BENVENISTE, H
    HEDLUND, LW
    JOHNSON, GA
    [J]. STROKE, 1992, 23 (05) : 746 - 754
  • [7] THE WORLDWIDE PROBLEM OF STROKE
    BONITA, R
    BEAGLEHOLE, R
    ASPLUND, K
    [J]. CURRENT OPINION IN NEUROLOGY, 1994, 7 (01) : 5 - 10
  • [8] Fluid-attenuated inversion recovery (FLAIR) for assessment of cerebral infarction - Initial clinical experience in 50 patients
    BrantZawadzki, M
    Atkinson, D
    Detrick, M
    Bradley, WG
    Scidmore, G
    [J]. STROKE, 1996, 27 (07) : 1187 - 1191
  • [9] EFFECT OF BULK TISSUE MOTION ON QUANTITATIVE PERFUSION AND DIFFUSION MAGNETIC-RESONANCE-IMAGING
    CHENEVERT, TL
    PIPE, JG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 261 - 265
  • [10] REPERFUSION FOLLOWING FOCAL STROKE HASTENS INFLAMMATION AND RESOLUTION OF ISCHEMIC INJURED TISSUE
    CLARK, RK
    LEE, EV
    WHITE, RF
    JONAK, ZL
    FEUERSTEIN, GZ
    BARONE, FC
    [J]. BRAIN RESEARCH BULLETIN, 1994, 35 (04) : 387 - 392