Development of the LPT9510 1 W concentric pulse tube

被引:0
|
作者
Mullié, J. C. [1 ]
Bruins, P. C. [1 ]
Benschop, T. [1 ]
Charles, I. [2 ]
Coynel, A. [2 ]
Duband, L. [2 ]
机构
[1] Thales Cryogen, NL-5600 HA Eindhoven, Netherlands
[2] CEA Grenoble, DRFMC, Serv Basses Temp, F-38054 Grenoble, France
关键词
pulse tube; cryogenic cooler;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
In order to provide cryogenic cooling for applications that are extremely sensitive to mechanical vibration, Thales Cryogenics has been delivering U-shape pulse tube cryocoolers since 2001. The disadvantage of the U-shape design is that the available regenerator volume is too limited if the application puts constrains on the overall diameter of the cold finger, thus limiting the coolers efficiency. As presented at CEC/ICMC 2003, Thales Cryogenics and CEA/SBT have achieved very good results with a large concentric pulse tube delivering 4W @ 77K driven by a flexure bearing compressor. Furthermore, the same team, together with Air Liquide DTA, developed a very efficient 1W pulse tube cooler for the ESA MPTC project. Based on the experiences obtained with those programs, Thales Cryogenics and CEA/SBT have now developed a small concentric pulse tube that is driven by a flexure bearing compressor. The result is a very compact and reliable cooler, with an efficiency that is nearly doubled compared to the U-shape version with the same overall external diameter dimensions. This paper describes the trade-offs that have been considered in the design phase, and gives a detailed overview of the test results, the status of the qualification program and a comparison with a comparable Stirling cold finger.
引用
收藏
页码:1332 / +
页数:2
相关论文
共 50 条
  • [1] Integrated Testing of the Thales LPT9510 Pulse Tube Cooler and the Iris LCCE Electronics
    Johnson, Dean L.
    Rodriguez, Jose I.
    Carroll, Brian A.
    Bustamante, John G.
    Kirkconnell, Carl S.
    Luong, Thomas. T.
    Murphy, J. B.
    Haley, Michael F.
    ADVANCES IN CRYOGENIC ENGINEERING, 2014, 1573 : 1806 - 1813
  • [2] The development of a pulse tube cooler with more than 1 W at 4.2 K
    Hofmann, A.
    Stautner, W.
    Pan, H.
    Crowley, D.
    Gilgrass, G.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 49 - +
  • [3] Development of a 1 to 5 W at 80 K stirling pulse tube cryocooler
    Hiratsuka, Y
    Kang, YM
    Matsubara, Y
    CRYOCOOLERS 10, 1999, : 149 - 155
  • [4] Development of the LPT6510 pulse-tube cooler for 60-150 K applications
    Arts, Roel
    Mullie, Jeroen
    Tanchon, Julien
    Trollier, Thierry
    CRYOGENICS, 2020, 105
  • [5] A pulse tube cooler capable of 1 W at 4.2 K
    Qiu, LM
    Jiang, N
    Giebeler, F
    Kuecuekkaplan, Y
    Thummes, G
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 113 - 116
  • [6] Development of a 2 W at 60 K pulse tube cryocooler for spaceborne operation
    Kotsubo, V
    Olson, JR
    Nast, TC
    CRYOCOOLERS 10, 1999, : 157 - 161
  • [7] Development of a 5 W/4.2 K two-stage pulse tube cryocooler
    Hao, X.
    Zerkle, B.
    Cosco, J.
    Dausman, R.
    ADVANCES IN CRYOGENIC ENGINEERING: PROCEEDINGS OF THE CRYOGENIC ENGINEERING CONFERENCE, CEC 2023, 2024, 1301
  • [8] Development of SHI 1.0 W4Ktwo-stage pulse tube cryocoolers
    Xu, M. Y.
    Gao, J. L.
    Seitz, E.
    Longsworth, R. C.
    Saito, M.
    Ikeya, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 51A AND B, 2006, 823 : 837 - +
  • [9] Development of the 3.5 W at 80 K high-frequency pulse tube cryocooler
    Jing, W.
    Wang, G. P.
    Liang, J. T.
    Cai, J. H.
    ICEC 20: PROCEEDINGS OF THE TWENTIETH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE, 2005, : 229 - 232
  • [10] Development of a 5 to 20W at 80 K GM pulse tube cryocooler
    Fujimoto, S
    Kang, YM
    Matsubara, Y
    CRYOCOOLERS 10, 1999, : 213 - 220