Microfabrication of stacks of acoustic matching layers for 15 MHz ultrasonic transducers

被引:24
作者
Tung Manh [1 ]
Anh-Tuan Thai Nguyen [1 ]
Johansen, Tonni F. [2 ,3 ]
Hoff, Lars [1 ]
机构
[1] Vestfold Univ Coll, Dept Micro & Nano Syst Technol, Horten, Norway
[2] SINTEF ICT, Dept Acoust, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7034 Trondheim, Norway
关键词
High frequency transducers; Silicon-polymer composite; Silicon micromachining; Matching layer; DESIGN; IMPEDANCE; EFFICIENT;
D O I
10.1016/j.ultras.2013.08.015
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper presents a novel method used to manufacture stacks of multiple matching layers for 15 MHz piezoelectric ultrasonic transducers, using fabrication technology derived from the MEMS industry. The acoustic matching layers were made on a silicon wafer substrate using micromachining techniques, i.e., lithography and etch, to design silicon and polymer layers with the desired acoustic properties. Two matching layer configurations were tested: a double layer structure consisting of a silicon-polymer composite and polymer and a triple layer structure consisting of silicon, composite, and polymer. The composite is a biphase material of silicon and polymer in 2-2 connectivity. The matching layers were manufactured by anisotropic wet etch of a (110)-oriented Silicon-on-Insulator wafer. The wafer was etched by KOH 40 wt%, to form 83 mu m deep and 4.5 mm long trenches that were subsequently filled with Spurr's epoxy, which has acoustic impedance 2.4 MRayl. This resulted in a stack of three layers: The silicon substrate, a silicon-polymer composite intermediate layer, and a polymer layer on the top. The stacks were bonded to PZT disks to form acoustic transducers and the acoustic performance of the fabricated transducers was tested in a pulse-echo setup, where center frequency, -6 dB relative bandwidth and insertion loss were measured. The transducer with two matching layers was measured to have a relative bandwidth of 70%, two-way insertion loss 18.4 dB and pulse length 196 ns. The transducers with three matching layers had fractional bandwidths from 90% to 93%, two-way insertion loss ranging from 18.3 to 25.4 dB, and pulse lengths 326 and 446 ns. The long pulse lengths of the transducers with three matching layers were attributed to ripple in the passband. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:614 / 620
页数:7
相关论文
共 50 条
[21]   Acoustic Characterization of Transmitted and Received Acoustic Properties of Air-Coupled Ultrasonic Transducers Based on Matching Layer of Organosilicon Hollow Glass Microsphere [J].
Xu, Xinhu ;
Zhang, Liang ;
Guo, Hulin ;
Wang, Xiaojie ;
Kong, Lingcai .
MICROMACHINES, 2023, 14 (11)
[22]   A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers [J].
Rathod, Vivek T. .
SENSORS, 2020, 20 (14) :1-65
[23]   Ultrahigh Frequency Ultrasonic Transducers (150MHz) Based on Silicon Lenses [J].
Chen, Jun ;
Fei, Chunlong ;
Zhao, Jianxin ;
Quan, Yi ;
Wang, Yecheng ;
Jiang, Zhishui ;
Wen, Li .
MICROMACHINES, 2023, 14 (01)
[24]   Ultrahigh frequency lensless ultrasonic transducers for acoustic tweezers application [J].
Lam, Kwok Ho ;
Hsu, Hsiu-Sheng ;
Li, Ying ;
Lee, Changyang ;
Lin, Anderson ;
Zhou, Qifa ;
Kim, Eun Sok ;
Shung, Kirk Koping .
BIOTECHNOLOGY AND BIOENGINEERING, 2013, 110 (03) :881-886
[25]   Active acoustic field modulation of ultrasonic transducers with flexible composites [J].
Hou, Chenxue ;
Li, Zhaoxi ;
Fei, Chunlong ;
Li, Yi ;
Wang, Yecheng ;
Zhao, Tianlong ;
Quan, Yi ;
Chen, Dongdong ;
Li, Xiaoping ;
Bao, Weimin ;
Yang, Yintang .
COMMUNICATIONS PHYSICS, 2023, 6 (01)
[26]   Analysis of Electrical Impedance Matching Effect of Phased Array Ultrasonic Transducers [J].
Jang, Jaewon ;
Lee, Hyosung ;
Kim, Geonwoo ;
Kim, Ki-Bok .
JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2023, 43 (05) :357-366
[27]   Electrical matching of low power piezoelectric ultrasonic transducers for microelectronic bonding [J].
Zhang, Hongjie ;
Wang, Fujun ;
Tian, Yanling ;
Zhao, Xingyu ;
Zhang, Dawei ;
Han, Lin .
SENSORS AND ACTUATORS A-PHYSICAL, 2013, 199 :241-249
[28]   Vacuum Deposition of Mass-Spring Matching Layers for High-Frequency Ultrasound Transducers [J].
Brown, J. ;
Sharma, S. ;
Leadbetter, J. ;
Cochran, S. ;
Adamson, R. .
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, :101-104
[29]   Optimization of the matching layer for high-frequency underwater acoustic transducers [J].
Wang, Chunying ;
Wang, Cong .