A novel amperometric nitric oxide sensor based on polythionine/nafion modified glassy carbon electrode

被引:0
|
作者
Chen, XX
Wang, F
Xu, YX
Hu, SS [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[2] Chinese Acad Sci, State Key Lab Transducer Technol, Beijing 100084, Peoples R China
关键词
amperometric sensor; nitric oxide; thionine; electrochemistry;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel amperometric sensor for the determination of nitric oxide was developed by coating polythionine/nafion on a glassy carbon electrode. This sensor exhibited a great enhancement to the oxidation of nitric oxide. The oxidation peak currents were linear to the concentration of nitric oxide over the wide range from 3.6 x 10(-7) to 6.8 x 10(-5) mol.L-1, and the detection limit was 7.2 x 10(-8) mol.L-1. Experimental results showed that this nitric oxide sensor possessed excellent selectivity and longer stability. NO releasing from rat kidney was monitored by this sensor.
引用
收藏
页码:496 / 498
页数:3
相关论文
共 50 条
  • [2] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Yazhen Wang
    Bin Song
    Junhui Xu
    Shengshui Hu
    Microchimica Acta, 2015, 182 : 711 - 718
  • [3] An amperometric sensor for nitric oxide based on a glassy carbon electrode modified with graphene, Nafion, and electrodeposited gold nanoparticles
    Wang, Yazhen
    Song, Bin
    Xu, Junhui
    Hu, Shengshui
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 711 - 718
  • [4] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [5] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Wang, Qingxia
    Zhang, Haili
    Wu, Yiwei
    Yu, Aimin
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 279 - 285
  • [6] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [7] Amperometric hydrogen peroxide biosensor based on a glassy carbon electrode modified with polythionine and gold nanoparticles
    Qingxia Wang
    Haili Zhang
    Yiwei Wu
    Aimin Yu
    Microchimica Acta, 2012, 176 : 279 - 285
  • [8] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Yusoff, Norazriena
    Rameshkumar, Perumal
    Shahid, Muhammad Mehmood
    Huang, Sheng-Tung
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2017, 184 (09) : 3291 - 3299
  • [9] Amperometric detection of nitric oxide using a glassy carbon electrode modified with gold nanoparticles incorporated into a nanohybrid composed of reduced graphene oxide and Nafion
    Norazriena Yusoff
    Perumal Rameshkumar
    Muhammad Mehmood Shahid
    Sheng-Tung Huang
    Nay Ming Huang
    Microchimica Acta, 2017, 184 : 3291 - 3299
  • [10] Glucose Biosensor Based on a Glassy Carbon Electrode Modified with Polythionine and Multiwalled Carbon Nanotubes
    Tang, Wenwei
    Li, Lei
    Wu, Lujun
    Gong, Jiemin
    Zeng, Xinping
    PLOS ONE, 2014, 9 (05):