Image artifacts in digital breast tomosynthesis: Investigation of the effects of system geometry and reconstruction parameters using a linear system approach

被引:116
作者
Hu, Yue-Houng [1 ]
Zhao, Bo [1 ]
Zhao, Wei [1 ]
机构
[1] SUNY Stony Brook, Dept Radiol, Stony Brook, NY 11794 USA
关键词
biology computing; image reconstruction; mammography; X-ray imaging;
D O I
10.1118/1.2996110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital breast tomosynthesis (DBT) is a three-dimensional (3D) x-ray imaging modality that reconstructs image slices parallel to the detector plane. Image acquisition is performed using a limited angular range (less than 50 degrees) and a limited number of projection views (less than 50 views). Due to incomplete data sampling, image artifacts are unavoidable in DBT. In this preliminary study, the image artifacts in DBT were investigated systematically using a linear system approximation. A cascaded linear system model of DBT was developed to calculate the 3D presampling modulation transfer function (MTF) with different image acquisition geometries and reconstruction filters using a filtered backprojection (FBP) algorithm. A thin, slanted tungsten (W) wire was used to measure the presampling MTF of the DBT system in the cross-sectional plane defined by the thickness (z-) and tube travel (x-) directions. The measurement was in excellent agreement with the calculation using the model. A small steel bead was used to calculate the artifact spread function (ASF) of the DBT system. The ASF was correlated with the convolution of the two-dimensional (2D) point spread function (PSF) of the system and the object function of the bead. The results showed that the cascaded linear system model can be used to predict the magnitude of image artifacts of small, high-contrast objects with different image acquisition geometry and reconstruction filters.
引用
收藏
页码:5242 / 5252
页数:11
相关论文
共 26 条
[1]  
AVINASH G, 2006, P SPIE, V6142
[2]   SELF-MASKING SUBTRACTION TOMOSYNTHESIS [J].
CHAKRABORTY, DP ;
YESTER, MV ;
BARNES, GT ;
LAKSHMINARAYANAN, AV .
RADIOLOGY, 1984, 150 (01) :225-229
[3]   Effect of acquisition parameters on image quality in digital tomosynthesis [J].
Deller, Timothy ;
Jabri, Kadri N. ;
Sabol, John M. .
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
[4]   IMAGE QUALITY INDEX (IQI) FOR SCREEN FILM MAMMOGRAPHY [J].
DESPONDS, L ;
DEPEURSINGE, C ;
GRECESCU, M ;
HESSLER, C ;
SAMIRI, A ;
VALLEY, JF .
PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (01) :19-33
[5]   High speed, large angle mammography tomosynthesis system - art. no. 61420C [J].
Eberhard, Jeffrey W. ;
Staudinger, Paul ;
Smolenski, Joe ;
Ding, Jason ;
Schmitz, Andrea ;
McCoy, Julie ;
Rumsey, Michael ;
Al-Khalidy, Abdulrahman ;
Ross, William ;
Landberg, Cynthia E. ;
Claus, Bernhard E. H. ;
Carson, Paul ;
Goodsitt, Mitchell ;
Chan, Heang-Ping ;
Roubidoux, Marilyn ;
Thomas, Jerry A. ;
Osland, Jacqueline .
Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 :C1420-C1420
[6]   A NEW DIGITAL TOMOSYNTHESIS METHOD WITH LESS ARTIFACTS FOR ANGIOGRAPHY [J].
HAAKER, P ;
KLOTZ, E ;
KOPPE, R ;
LINDE, R ;
MOLLER, H .
MEDICAL PHYSICS, 1985, 12 (04) :431-436
[7]   THE NOISE POWER SPECTRUM OF CT IMAGES [J].
KIJEWSKI, MF ;
JUDY, PF .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (05) :565-575
[8]   A METHOD FOR SELECTIVE REMOVAL OF OUT-OF-PLANE STRUCTURES IN DIGITAL TOMOSYNTHESIS [J].
KOLITSI, Z ;
PANAYIOTAKIS, G ;
PALLIKARAKIS, N .
MEDICAL PHYSICS, 1993, 20 (01) :47-50
[9]   A theoretical framework for filtered backprojection in tomosynthesis [J].
Lauritsch, G ;
Harer, WH .
MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 :1127-1137
[10]   Effect of estrogen replacement therapy on the specificity and sensitivity of screening mammography [J].
Laya, MB ;
Larson, EB ;
Taplin, SH ;
White, E .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1996, 88 (10) :643-649