Comparing Performance of Centerline Algorithms for Quantitative Assessment of Brain Vascular Anatomy

被引:13
作者
Diedrich, Karl T. [1 ]
Roberts, John A. [1 ]
Schmidt, Richard H. [2 ]
Parker, Dennis L. [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Neurosurg, Hlth Sci Ctr, Salt Lake City, UT 84108 USA
来源
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY | 2012年 / 295卷 / 12期
关键词
centerline; MRA; stability; vascular; MIP Z-BUFFER; RESONANCE; TORTUOSITY;
D O I
10.1002/ar.22603
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Attributes like length, diameter, and tortuosity of tubular anatomical structures such as blood vessels in medical images can be measured from centerlines. This study develops methods for comparing the accuracy and stability of centerline algorithms. Sample data included numeric phantoms simulating arteries and clinical human brain artery images. Centerlines were calculated from segmented phantoms and arteries with shortest paths centerline algorithms developed with different cost functions. The cost functions were the inverse modified distance from edge (MDFEi), the center of mass (COM), the binary-thinned (BT)-MDFEi, and the BT-COM. The accuracy of the centerline algorithms were measured by the root mean square error from known centerlines of phantoms. The stability of the centerlines was measured by starting the centerline tree from different points and measuring the differences between trees. The accuracy and stability of the centerlines were visualized by overlaying centerlines on vasculature images. The BT-COM cost function centerline was the most stable in numeric phantoms and human brain arteries. The MDFEi-based centerline was most accurate in the numeric phantoms. The COM-based centerline correctly handled the "kissing" artery in 16 of 16 arteries in eight subjects whereas the BT-COM was correct in 10 of 16 and MDFEi was correct in 6 of 16. The COM-based centerline algorithm was selected for future use based on the ability to handle arteries where the initial binary vessels segmentation exhibits closed loops. The selected COM centerline was found to measure numerical phantoms to within 2% of the known length. Anat Rec, 295:2179-2190, 2012. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:2179 / 2190
页数:12
相关论文
共 20 条
[11]   A review of 3D vessel lumen segmentation techniques: Models, features and extraction schemes [J].
Lesage, David ;
Angelini, Elsa D. ;
Bloch, Isabelle ;
Funka-Lea, Gareth .
MEDICAL IMAGE ANALYSIS, 2009, 13 (06) :819-845
[12]   Methods for three-dimensional geometric characterization of the arterial vasculature [J].
O'Flynn, Padraig M. ;
O'Sullivan, Gerard ;
Pandit, Abhay S. .
ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (08) :1368-1381
[13]  
Parker DL, 2000, JMRI-J MAGN RESON IM, V11, P378, DOI 10.1002/(SICI)1522-2586(200004)11:4<378::AID-JMRI5>3.3.CO
[14]  
2-R
[15]  
Pournelle G. H., 1953, Journal of Mammalogy, V34, P133, DOI 10.1890/0012-9658(2002)083[1421:SDEOLC]2.0.CO
[16]  
2
[17]  
Rasband WS, 1997, ImageJ
[18]   THE APPLICATION OF TOTAL VERTICAL PROJECTIONS FOR THE UNBIASED ESTIMATION OF THE LENGTH OF BLOOD-VESSELS AND OTHER STRUCTURES BY MAGNETIC-RESONANCE-IMAGING [J].
ROBERTS, N ;
HOWARD, CV ;
CRUZORIVE, LM ;
EDWARDS, RHT .
MAGNETIC RESONANCE IMAGING, 1991, 9 (06) :917-925
[19]   Calibration-free device sizing using an inverse geometry x-ray system [J].
Tomkowiak, Michael T. ;
Speidel, Michael A. ;
Raval, Amish N. ;
Van Lysel, Michael S. .
MEDICAL PHYSICS, 2011, 38 (01) :283-293
[20]   Automatic detection of three-dimensional vascular tree centerlines and bifurcations in high-resolution magnetic resonance angiography [J].
Zhang, L ;
Chapman, BE ;
Parker, DL ;
Roberts, JA ;
Guo, JY ;
Vemuri, P ;
Moon, SM ;
Noo, F .
INVESTIGATIVE RADIOLOGY, 2005, 40 (10) :661-671