Comparing Performance of Centerline Algorithms for Quantitative Assessment of Brain Vascular Anatomy

被引:13
作者
Diedrich, Karl T. [1 ]
Roberts, John A. [1 ]
Schmidt, Richard H. [2 ]
Parker, Dennis L. [1 ]
机构
[1] Univ Utah, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
[2] Univ Utah, Dept Neurosurg, Hlth Sci Ctr, Salt Lake City, UT 84108 USA
来源
ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY | 2012年 / 295卷 / 12期
关键词
centerline; MRA; stability; vascular; MIP Z-BUFFER; RESONANCE; TORTUOSITY;
D O I
10.1002/ar.22603
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Attributes like length, diameter, and tortuosity of tubular anatomical structures such as blood vessels in medical images can be measured from centerlines. This study develops methods for comparing the accuracy and stability of centerline algorithms. Sample data included numeric phantoms simulating arteries and clinical human brain artery images. Centerlines were calculated from segmented phantoms and arteries with shortest paths centerline algorithms developed with different cost functions. The cost functions were the inverse modified distance from edge (MDFEi), the center of mass (COM), the binary-thinned (BT)-MDFEi, and the BT-COM. The accuracy of the centerline algorithms were measured by the root mean square error from known centerlines of phantoms. The stability of the centerlines was measured by starting the centerline tree from different points and measuring the differences between trees. The accuracy and stability of the centerlines were visualized by overlaying centerlines on vasculature images. The BT-COM cost function centerline was the most stable in numeric phantoms and human brain arteries. The MDFEi-based centerline was most accurate in the numeric phantoms. The COM-based centerline correctly handled the "kissing" artery in 16 of 16 arteries in eight subjects whereas the BT-COM was correct in 10 of 16 and MDFEi was correct in 6 of 16. The COM-based centerline algorithm was selected for future use based on the ability to handle arteries where the initial binary vessels segmentation exhibits closed loops. The selected COM centerline was found to measure numerical phantoms to within 2% of the known length. Anat Rec, 295:2179-2190, 2012. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:2179 / 2190
页数:12
相关论文
共 20 条
[1]   Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional magnetic resonance angiography [J].
Arimura, H ;
Li, Q ;
Korogi, Y ;
Hirai, T ;
Abe, H ;
Yamashita, Y ;
Katsuragawa, S ;
Ikeda, R ;
Doi, K .
ACADEMIC RADIOLOGY, 2004, 11 (10) :1093-1104
[2]   Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction [J].
Aylward, SR ;
Bullitt, E .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (02) :61-75
[3]   Measuring tortuosity of the intracerebral vasculature from MRA images [J].
Bullitt, E ;
Gerig, G ;
Pizer, SM ;
Lin, WL ;
Aylward, SR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (09) :1163-1171
[4]  
Burger W., 2007, Digital Image Processing: An Algorithmic Introduction using Java, V1st
[5]   Intracranial vessel segmentation from time-of-flight MRA using pre-processing of the MIP Z-buffer: accuracy of the ZBS algorithm [J].
Chapman, BE ;
Stapelton, JO ;
Parker, DL .
MEDICAL IMAGE ANALYSIS, 2004, 8 (02) :113-126
[6]  
Dijkstra E. W., 1959, Numerische Mathematik, V1, P269, DOI [10.1007/BF01386390, DOI 10.1007/BF01386390]
[7]   Model-based quantitation of 3-D magnetic resonance angiographic images [J].
Frangi, AF ;
Niessen, WJ ;
Hoogeveen, RM ;
van Walsum, T ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) :946-956
[8]   Tortuosity of the white matter medullary arterioles is related to the severity of hypertension [J].
Hiroki, M ;
Miyashita, K ;
Oda, M .
CEREBROVASCULAR DISEASES, 2002, 13 (04) :242-250
[9]  
Homman H., 2007, Insight Journal - Implementation of a 3D thinning algorithm
[10]   Three-Dimensional Blood Vessel Quantification via Centerline Deformation [J].
Kang, Dong-Goo ;
Suh, Dae Chul ;
Ra, Jong Beom .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (03) :405-414