Combined imaging of potassium and sodium in human skeletal muscle tissue at 7 T

被引:17
作者
Gast, Lena, V [1 ,2 ]
Volker, Stefanie [1 ]
Utzschneider, Matthias [1 ,3 ]
Linz, Peter [1 ]
Wilferth, Tobias [1 ]
Muller, Max [1 ]
Kopp, Christoph [4 ]
Hensel, Bernhard [5 ]
Uder, Michael [1 ]
Nagel, Armin M. [1 ,2 ,6 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg FAU, Univ Hosp Erlangen, Inst Radiol, Maximilianspl 3, D-91054 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg FAU, Inst Med Phys, Erlangen, Germany
[3] Friedrich Alexander Univ Erlangen Nurnberg, Dept Comp Sci, Pattern Recognit Lab, Erlangen, Germany
[4] Friedrich Alexander Univ Erlangen Nurnberg FAU, Dept Nephrol & Hypertens, Erlangen, Germany
[5] Friedrich Alexander Univ Erlangen Nurnberg FAU, Ctr Med Phys & Engn, Erlangen, Germany
[6] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
关键词
7; T; potassium MRI; sodium MRI; tissue potassium concentration; tissue sodium concentration; ultrahigh field strengths; IN-VIVO K-39; NA-23; MRI; INTRACELLULAR SODIUM; RELAXATION-TIMES; HEALTHY-SUBJECTS; NMR; SPECTROSCOPY; AGREEMENT; EXERCISE; SHIFTS;
D O I
10.1002/mrm.28428
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To validate the feasibility of quantitative combined potassium (K-39) and sodium (Na-23) MRI in human calf muscle tissue, as well as to evaluate the reproducibility of the apparent tissue potassium concentration (aTPC) and apparent tissue sodium concentration (aTSC) determination in healthy muscle tissue. Methods Quantitative(23)Na and(39)K MRI acquisition protocols were implemented on a 7 T MR system. A double-resonant(23)Na/K-39 birdcage RF coil was used. Measurements of human lower leg were performed in a total acquisition time of TA(Na)= 10:54 min/TA(K)= 8:06 min and using a nominal spatial resolution of 2.5 x 2.5 x 15 mm(3)/7.5 x 7.5 x 30 mm(3)for(23)Na/K-39 MRI. Two aTSC and aTPC examinations in muscle tissue were performed during the same day on 10 healthy subjects. Results The proposed acquisition and postprocessing workflow for(23)Na and(39)K MRI data sets provided reproducible aTSC and aTPC measurements. In human calf muscle tissue, the coefficient of variation between scan and re-scan was 5.7% for both aTSC and aTPC determination. Overall, mean values of aTSC = (17 +/- 1) mM and aTPC = (85 +/- 5) mM were measured. Moreover, for(39)K in calf muscle tissue,T2*components ofT2f*= (1.2 +/- 0.2) ms andT2s*= (7.9 +/- 0.9) ms, as well as a residual quadrupolar interaction of omega q over bar = (143 +/- 17) Hz, were determined. The fraction of the fast component was f = (58 +/- 4)%. Conclusion Using the presented measurement and postprocessing approach, a reproducible aTSC and aTPC determination using(23)Na and(39)K MRI at 7 T in human skeletal muscle tissue is feasible in clinically acceptable acquisition durations.
引用
收藏
页码:253 / 267
页数:15
相关论文
共 52 条
[1]   Hyperkalemic Periodic Paralysis and Permanent Weakness: 3-T MR Imaging Depicts Intracellular 23Na Overload-Initial Results [J].
Amarteifio, Erick ;
Nagel, Armin M. ;
Weber, Marc-Andre ;
Jurkat-Rott, Karin ;
Lehmann-Horn, Frank .
RADIOLOGY, 2012, 264 (01) :154-163
[2]   Feasibility of 39-Potassium MR Imaging of a Human Brain at 9.4 Tesla [J].
Atkinson, Ian C. ;
Claiborne, Theodore C. ;
Thulborn, Keith R. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (05) :1819-1825
[3]   In vivo 39K, 23Na and 1H MR imaging using a triple resonant RF coil setup [J].
Augath, Mark ;
Heiler, Patrick ;
Kirsch, Stefan ;
Schad, Lothar R. .
JOURNAL OF MAGNETIC RESONANCE, 2009, 200 (01) :134-136
[4]  
Bansal N, 2000, J MAGN RESON IMAGING, V11, P532
[5]   SKELETAL MUSCLE ANALYSES IN HEALTH AND IN CERTAIN METABOLIC DISORDERS .1. THE METHOD OF ANALYSIS AND THE VALUES IN NORMAL MUSCLE [J].
BARNES, BA ;
GORDON, EB ;
COPE, O .
JOURNAL OF CLINICAL INVESTIGATION, 1957, 36 (08) :1239-1248
[6]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[7]   Sodium MRI revisited [J].
Burstein, Deborah ;
Springer, Charles S. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (02) :521-524
[8]   Na+-K+ pump regulation and skeletal muscle contractility [J].
Clausen, T .
PHYSIOLOGICAL REVIEWS, 2003, 83 (04) :1269-1324
[9]   Human skeletal muscle: Sodium MR imaging and quantification-potential applications in exercise and disease [J].
Constantinides, CD ;
Gillen, JS ;
Boada, FE ;
Pomper, MG ;
Bottomley, PA .
RADIOLOGY, 2000, 216 (02) :559-568
[10]   Reliability and agreement of sodium (23Na) MRI in calf muscle and skin of healthy subjects from the US [J].
Dyke, Jonathan P. ;
Meyring-Wosten, Anna ;
Zhao, Yize ;
Linz, Peter ;
Thijssen, Stephan ;
Kotanko, Peter .
CLINICAL IMAGING, 2018, 52 :100-105