Reliability of acuities determined with the sweep visual evoked potential (sVEP)

被引:16
作者
Ridder, William H., III [1 ]
Tong, Anna [1 ]
Floresca, Theresa [1 ]
机构
[1] So Calif Coll Optometry, Fullerton, CA 92831 USA
关键词
Visual acuity; Sweep visual evoked potential; logMAR acuity; VEP ACUITY; CHILDREN; VISION;
D O I
10.1007/s10633-012-9312-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
sVEPs are generally used to rapidly obtain visual acuity. Several studies have determined the reliability of acuity measurements with psychophysical techniques. The aim of this study was to determine the intersession and intrasession variabilities of sVEP measurements. Twenty-four normal, adult subjects took part in this project. Stimulus production and data analyses were done using an Enfant 4010. Standard VEP recording techniques were employed. Data were collected on two separate days (at least 1 week apart). At each visit, two complete sets of sVEP data were collected and averaged. A logMAR acuity chart was also used to determine the acuity at each visit. Paired t tests, 95% confidence intervals, intraclass correlation coefficients, and coefficients of repeatability were used to determine whether there was a difference in the intrasession and intersession acuities. The mean acuity difference and coefficient of repeatability were +0.01 and 0.191 for visit 1 and -0.019 and 0.186 for visit 2, respectively. The mean acuity difference and coefficient of repeatability across visits were +0.008 and 0.176 for the first acuity and-0.02 and 0.170 for the second acuity, respectively. Paired t tests did not find a significant difference between any set of data or the average for visits one and two (all P values > 0.05). The intraclass correlation coefficients comparing the average sVEP data and the logMAR data for visits 1 and 2 were 0.71 and 0.88, respectively. The coefficients of repeatability for the averaged sVEP acuity and the logMAR acuity for the two visits were 0.11 and 0.07, respectively. The repeatability of the sVEP acuity estimate in a large population of adults is similar to that of previous published reports on infants and is nearly as high as that of logMAR acuity chart data. The repeatability is the same for single best estimates of acuity and averaged estimates of acuity across visits.
引用
收藏
页码:99 / 107
页数:9
相关论文
共 50 条
  • [41] Effect of different stimulus configurations on the visual evoked potential (VEP)
    Yadav, Naveen K.
    Ludlam, Diana P.
    Ciuffreda, Kenneth J.
    DOCUMENTA OPHTHALMOLOGICA, 2012, 124 (03) : 177 - 196
  • [42] Preoperative visual evoked potential in the prediction of visual outcome after pituitary macroadenomas surgery
    Mohammad Taghvaei
    Seyed Mousa Sadrehosseini
    Nima Ostadrahimi
    Payam Sarraf
    Mehdi Zeinalizadeh
    Pituitary, 2019, 22 : 397 - 404
  • [43] Preoperative visual evoked potential in the prediction of visual outcome after pituitary macroadenomas surgery
    Taghvaei, Mohammad
    Sadrehosseini, Seyed Mousa
    Ostadrahimi, Nima
    Sarraf, Payam
    Zeinalizadeh, Mehdi
    PITUITARY, 2019, 22 (04) : 397 - 404
  • [44] Threshold Determination Criterion in Steady-State Visual Evoked Potential-Based Acuity Assessment: A Comparison of Four Common Methods
    Zheng, Xiaowei
    Xu, Guanghua
    Yan, Wenqiang
    Liang, Renghao
    Zhang, Kai
    Tian, Peiyuan
    Han, Zezhen
    IEEE ACCESS, 2020, 8 : 188844 - 188852
  • [45] RETINOSCOPY AND VISUAL EVOKED POTENTIAL BASED EVALUATION OF THE EXACTNESS OF HYPEROPIA CORRECTION IN CHILDREN WITH DEVELOPMENTAL DIFFICULTIES
    Karlica, Dobrila
    Galetovic, Davor
    Bucan, Kajo
    Znaor, Ljubo
    ACTA CLINICA CROATICA, 2010, 49 (03) : 251 - 255
  • [46] Prediction of higher visual function in macular degeneration with multifocal electroretinogram and multifocal visual evoked potential
    Herbik, Anne
    Geringswald, Franziska
    Thieme, Hagen
    Pollmann, Stefan
    Hoffmann, Michael B.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (05) : 540 - 551
  • [47] Objective visual performance evaluation with visual evoked potential measurements based on an adaptive optics system
    Yang, Yanrong
    Zhao, Junlei
    Zhao, Haoxin
    Xiao, Fei
    Xie, Jiaxin
    Liu, Tiejun
    Dai, Yun
    CHINESE OPTICS LETTERS, 2018, 16 (05)
  • [48] A comparison of the performance of three visual evoked potential-based methods to estimate visual acuity
    Anne Kurtenbach
    Hana Langrová
    Andre Messias
    Eberhart Zrenner
    Herbert Jägle
    Documenta Ophthalmologica, 2013, 126 : 45 - 56
  • [49] Objective measurement of contrast sensitivity and visual acuity with the steady-state visual evoked potential
    Strasburger, H
    Remky, A
    Murray, IJ
    Hadjizenonos, C
    Rentschler, I
    GERMAN JOURNAL OF OPHTHALMOLOGY, 1996, 5 (01) : 42 - 52
  • [50] THE EFFECTS OF AGING ON THE PATTERN ELECTRORETINOGRAM AND VISUAL EVOKED-POTENTIAL IN HUMANS
    PORCIATTI, V
    BURR, DC
    MORRONE, MC
    FIORENTINI, A
    VISION RESEARCH, 1992, 32 (07) : 1199 - 1209