共 10 条
Effect of Optison on Pulmonary Artery Systolic Pressure and Pulmonary Vascular Resistance
被引:12
作者:
Main, Michael L.
[1
]
Graybum, Paul A.
[2
]
Lang, Roberto M.
[3
]
Goldman, Jonathan H.
[4
]
Gibson, C. Michael
[5
]
Sherwin, Paul
[6
]
DeMaria, Anthony N.
[7
]
机构:
[1] St Lukes Hlth Syst, St Lukes Mid Amer Heart Inst, Kansas City, MO USA
[2] Baylor Hlth Care Syst, Baylor Heart & Vasc Inst, Div Cardiol, Dept Internal Med, Dallas, TX USA
[3] Univ Chicago, Med Ctr, Dept Med, Cardiol Sect, Chicago, IL 60637 USA
[4] ICON Clin Res, N Wales, PA USA
[5] Harvard Univ, Beth Israel Deaconess Med Ctr, Dept Med, Sch Med, Boston, MA 02215 USA
[6] GE Healthcare, Med Diagnost, Clin Dev, Princeton, NJ USA
[7] Univ Calif San Diego, Dept Med, La Jolla, CA 92093 USA
关键词:
ULTRASOUND CONTRAST AGENT;
ECHOCARDIOGRAPHY;
SAFETY;
DEFINITY;
D O I:
10.1016/j.amjcard.2013.07.026
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Ultrasound contrast agent safety has received recent attention based on reports of associated serious adverse events. The US Food and Drug Administration requested this post-marketing study of the effects of Optison on pulmonary hemodynamics. The aim of this study was to compare Optison and a placebo for effects on pulmonary artery systolic pressure (PASP) and pulmonary vascular resistance (PVR) during right-sided cardiac catheterization. This was a single-blind, crossover, placebo-controlled, multicenter study of Optison in subjects referred for clinically indicated cardiac catheterization. Based on screening echocardiographic PASP, subjects were assigned to 1 of 2 strata (1 = normal PASP [<= 35 mm Hg] and 2 = elevated PASP [>35 mm Hg]), in which they were randomized to treatment arm A (intravenous 0.5 ml Optison and then intravenous 0.5 ml placebo [5% dextrose] 15 minutes later) or arm B (intravenous 0.5 ml placebo [5% dextrose] and then 0.5 ml Optison 15 minutes later). Baseline pulmonary hemodynamics were obtained within 60 minutes before the first injection and 2, 6, and 10 minutes after each injection. Thirty patients each received their assigned treatments. There were no clinically relevant increases from baseline in mean PASP or PVR (Wood units) in either stratum alone or the combined strata. There were no serious adverse events. In conclusion, there is no change in PASP or PVR after intravenous injection of Optison at a clinically relevant dose in patients with normal or elevated baseline PASP. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1657 / 1661
页数:5
相关论文