Numerical simulation of a ground-coupled heat pump system with vertical plate heat exchangers: A comprehensive parametric study

被引:18
|
作者
Amadeh, Ali [1 ]
Habibi, Mohammad [1 ]
Hakkaki-Fard, Ali [1 ]
机构
[1] Sharif Univ Technol, Dept Mech Engn, RASES Lab, Azadi Ave, Tehran, Iran
关键词
Ground-coupled heat pump; Vertical plate ground heat exchanger; Parametric study; Numerical simulation; THERMAL PERFORMANCE; ENERGY; MODEL;
D O I
10.1016/j.geothermics.2020.101913
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Plate ground heat exchangers (GHEs) are renowned for having the highest heat transfer rate per unit land area and could be of interest when the accessible land area is limited. In this study, a 3-D numerical model is developed to investigate the thermal performance of vertical plate GHEs at the real-scale level. The proposed model accounts for ambient temperature fluctuations and building cooling load variations and is such developed to couple the GHE to the heat pump. The effects of different parameters, including GHE spacing, buried depth, the height of GHE, soil type, and climate on the thermal performance of vertical plate GHEs, are comprehensively investigated for the first time. The optimum distance between two adjacent GHEs is obtained to be about 4 m to avoid the adverse effect of thermal interference. It is demonstrated that increasing GHE spacing dramatically increases cooling load per unit GHE area for values below 4 m while decreasing cooling load per unit land area. As a case in point, increasing GHE spacing from 2 m to 4 m increases cooling load per unit GHE area by 30.1 % while lowering cooling load per unit land area by 34.9 %. It can be inferred from the simulation results that soil type has the most critical effect on the thermal performance of vertical plate GHEs, and better thermal performance can be achieved when GHEs are buried in a soil type with higher thermal conductivity as well as higher heat capacity. The results also indicate that selecting proper values for buried depth and height is in fact finding a compromise between thermal performance and excavation cost. Investigating the effect of climate reveals that the maximum cooling load per unit GHE area is decreased by 37.7 % when the GCHP system operates in Ahvaz (hot climate) rather than Tehran (mild climate). However, when the GCHP system is designed to operate in Tabriz (cold climate), the maximum cooling load improves by 17.4 %.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A parametric study on the exergoeconomic assessment of a vertical ground-coupled (geothermal) heat pump system
    Ozgener, Onder
    Hepbasli, Arif
    Ozgener, Leyla
    BUILDING AND ENVIRONMENT, 2007, 42 (03) : 1503 - 1509
  • [2] Optimization and Analysis of a Vertical Ground-Coupled Heat Pump
    Kord, Ali Siavoshi
    Jazayeri, Seyed Ali
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2012, 2 (01): : 33 - 37
  • [3] A numerical study on utilizing horizontal flat-panel ground heat exchangers in ground-coupled heat pumps
    Habibi, Mohammad
    Amadeh, Ali
    Hakkaki-Fard, Ali
    RENEWABLE ENERGY, 2020, 147 : 996 - 1010
  • [4] Simulation study on the thermal performance of vertical U-tube heat exchangers for ground source heat pump system
    Pu, Liang
    Qi, Di
    Li, Kang
    Tan, Hongbo
    Li, Yanzhong
    APPLIED THERMAL ENGINEERING, 2015, 79 : 202 - 213
  • [5] NUMERICAL INVESTIGATION OF GROUND-COUPLED VERTICAL BOREHOLE HEAT EXCHANGERS WITH GROUNDWATER ADVECTION
    Piller, Marzio
    Scorpo, Alberto Liuzzo
    HEAT TRANSFER RESEARCH, 2012, 43 (04) : 343 - 362
  • [6] Energy and exergy analysis of a ground-coupled heat pump system with two horizontal ground heat exchangers
    Esen, Hikmet
    Inalli, Mustafa
    Esen, Mehmet
    Pihtili, Kazim
    BUILDING AND ENVIRONMENT, 2007, 42 (10) : 3606 - 3615
  • [7] An in situ thermal response test for borehole heat exchangers of the ground-coupled heat pump system
    Yang, Weibo
    Chen, Zhenqian
    Shi, Mingheng
    Zhang, Chengbin
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2013, 32 (05) : 489 - 503
  • [8] Sensitivity analysis of the ground-coupled heat pump system with horizontal ground heat exchangers in the cold regions of China
    Cang Tong
    Xiangli Li
    Lin Duanmu
    Building Simulation, 2019, 12 : 573 - 584
  • [9] Temperature distributions in boreholes of a vertical ground-coupled heat pump system
    Esen, Hikmet
    Inalli, Mustafa
    Esen, Yuksel
    RENEWABLE ENERGY, 2009, 34 (12) : 2672 - 2679
  • [10] Simulation and experimental analysis of optimal buried depth of the vertical U-tube ground heat exchanger for a ground-coupled heat pump system
    Chen, Jinhua
    Xia, Lei
    Li, Baizhan
    Mmereki, Daniel
    RENEWABLE ENERGY, 2015, 73 : 46 - 54