Quantitative estimation of aortic valve calcification in multislice computed tomography in predicting the development of paravalvular leaks following transcatheter aortic valve replacement

被引:5
|
作者
Rys, Malgorzata [1 ]
Hryniewiecki, Tomasz
Michalowska, Ilona [2 ]
Stoklosa, Patrycjusz [1 ]
Rozewicz-Juraszek, Monika [1 ]
Chmielak, Zbigniew [3 ]
Dabrowski, Maciej [3 ]
Mirota, Kryspin [4 ]
Szymanski, Piotr [1 ]
机构
[1] Inst Cardiol, Dept Valvular Heart Dis, 42 Alpejska St, PL-04628 Warsaw, Poland
[2] Inst Cardiol, Dept Radiol, Warsaw, Poland
[3] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[4] Univ Bielsko Biala, Fac Mech Engn & Comp Sci, Bielsko Biala, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 01期
关键词
aortic stenosis; transcatheter aortic valve implantation; aortic regurgitation; COREVALVE PROSTHESIS; IMPLANTATION; REGURGITATION; IMPACT; SEVERITY; LOCATION; STENOSIS; CALCIUM; SURGERY; DEVICE;
D O I
10.5114/aic.2018.74359
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Transcatheter aortic valve implantation (TAVI) improves prognosis in patients disqualified from surgical valve replacement. Calcifications of the aortic complex can lead to deformation of the prosthesis, resulting in paravalvular leaks (PVL). Aim: To evaluate the predictive value of quantitative estimation of volume/weight and geometric distribution of calcifications in multislice computed tomography, for the development of PVL. Material and methods: This was a retrospective, case-control study on patients with a CoreValve aortic prosthesis. The study group consisted of 20 patients with confirmed significant PVL after TAVI. The control group consisted of 20 patients without significant PVL, matched according to valve type and clinical characteristics. The size spatial distribution and shape of calcifications were measured. Results: The average age of patients was 79.9 years (60% women). Cases and controls did not differ in their clinical characteristics. The size of the aortic annulus was significantly larger in cases vs. controls (23.4 +/- 1.6 vs. 22 +/- 1.4 mm, p = 0.01). Volume, area and curvature of calcifications were greater in cases vs controls (1.09 +/- 0.56 vs. 0.59 +/- 0.41 cm(3), p = 0.011; 15.26 +/- 5.46 vs. 9.50 +/- 5.29 cm(2), p = 0.008; 1.76 +/- 0.07 vs. 1.68 +/- 0.13 cm(3), p = 0.037). In multivariate analysis, adjusted for aortic annulus size, the area of aortic valve calcifications independently predicted paravalvular regurgitation (OR = 1.41, 95% CI: 0.09-1.92, p < 0.009). Conclusions: Morphometric analysis of aortic valve calcifications predicted the risk of paravalvular leak following TAVI irrespectively of patients' clinical characteristics.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 50 条
  • [31] Quantified degree of eccentricity of aortic valve calcification predicts risk of paravalvular regurgitation and response to balloon post-dilation after self-expandable transcatheter aortic valve replacement
    Park, Jun-Bean
    Hwang, In-Chang
    Lee, Whal
    Han, Jung-Kyu
    Kim, Chi-Hoon
    Lee, Seung-Pyo
    Yang, Han-Mo
    Park, Eun-Ah
    Kim, Hyung-Kwan
    Chiam, Paul T. L.
    Kim, Yong-Jin
    Koo, Bon-Kwon
    Sohn, Dae-Won
    Ahn, Hyuk
    Kang, Joon-Won
    Park, Seung-Jung
    Kim, Hyo-Soo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 259 : 60 - 68
  • [32] Comparison of multislice computed tomography findings between bicuspid and tricuspid aortic valves before and after transcatheter aortic valve implantation
    Watanabe, Yusuke
    Chevalier, Bernard
    Hayashida, Kentaro
    Leong, Tora
    Bouvier, Erik
    Arai, Takahide
    Farge, Arnaud
    Hovasse, Thomas
    Garot, Philippe
    Cormier, Bertrand
    Morice, Marie-Claude
    Lefevre, Thierry
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 86 (02) : 323 - 330
  • [33] Predictive Value of Aortic Valve Calcium Volume Measured by Computed Tomography for Paravalvular Leakage After Transcatheter Aortic Valve Implantation
    Isomatsu, Daisuke
    Sato, Akihiko
    Muto, Yuuki
    Sato, Yu
    Shimizu, Takeshi
    Misaka, Tomofumi
    Kaneshiro, Takashi
    Oikawa, Masayoshi
    Kobayashi, Atsushi
    Yoshihisa, Akiomi
    Yamaki, Takayoshi
    Kunii, Hiroyuki
    Nakazato, Kazuhiko
    Ishida, Takafumi
    Sekino, Hirofumi
    Fukushima, Kenji
    Ito, Hiroshi
    Takeishi, Yasuchika
    INTERNATIONAL HEART JOURNAL, 2024, 65 (01) : 63 - 70
  • [34] Paravalvular Aortic Leak After Transcatheter Aortic Valve Replacement Current Knowledge
    Lerakis, Stamatios
    Hayek, Salim S.
    Douglas, Pamela S.
    CIRCULATION, 2013, 127 (03) : 397 - 407
  • [35] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [36] Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation
    Leipsic, Jonathon
    Gurvitch, Ronen
    LaBounty, Troy M.
    Min, James K.
    Wood, David
    Johnson, Mark
    Ajlan, Amr M.
    Wijesinghe, Namal
    Webb, John G.
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 416 - 429
  • [37] Advances in transcatheter aortic valve replacement
    Ando, Tomo
    Briasoulis, Alexandros
    Panaich, Sidakpal
    JOURNAL OF GERIATRIC CARDIOLOGY, 2019, 16 (09) : 724 - 732
  • [38] Paravalvular Leak Closure After Transcatheter Aortic Valve Replacement With a Self-Expanding Prosthesis
    Gafoor, Sameer
    Franke, Jennifer
    Piayda, Kerstin
    Lam, Simon
    Bertog, Stefan
    Vaskelyte, Laura
    Hofmann, Ilona
    Sievert, Horst
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (01) : 147 - 154
  • [39] Transcatheter Aortic Valve Replacement
    Welt, Frederick G. P.
    Davidson, Michael J.
    Leon, Martin B.
    Eisenhauer, Andrew C.
    CIRCULATION, 2011, 124 (25) : 2944 - 2948
  • [40] Cardiac computed tomography post-transcatheter aortic valve replacement
    He, Albert
    Wilkins, Ben
    Lan, Nick S. R.
    Othman, Farrah
    Sehly, Amro
    Bhat, Vikas
    Jaltotage, Biyanka
    Dwivedi, Girish
    Leipsic, Jonathon
    Ihdayhid, Abdul Rahman
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2024, 18 (04) : 319 - 326