Quantitative estimation of aortic valve calcification in multislice computed tomography in predicting the development of paravalvular leaks following transcatheter aortic valve replacement

被引:5
|
作者
Rys, Malgorzata [1 ]
Hryniewiecki, Tomasz
Michalowska, Ilona [2 ]
Stoklosa, Patrycjusz [1 ]
Rozewicz-Juraszek, Monika [1 ]
Chmielak, Zbigniew [3 ]
Dabrowski, Maciej [3 ]
Mirota, Kryspin [4 ]
Szymanski, Piotr [1 ]
机构
[1] Inst Cardiol, Dept Valvular Heart Dis, 42 Alpejska St, PL-04628 Warsaw, Poland
[2] Inst Cardiol, Dept Radiol, Warsaw, Poland
[3] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[4] Univ Bielsko Biala, Fac Mech Engn & Comp Sci, Bielsko Biala, Poland
来源
POSTEPY W KARDIOLOGII INTERWENCYJNEJ | 2018年 / 14卷 / 01期
关键词
aortic stenosis; transcatheter aortic valve implantation; aortic regurgitation; COREVALVE PROSTHESIS; IMPLANTATION; REGURGITATION; IMPACT; SEVERITY; LOCATION; STENOSIS; CALCIUM; SURGERY; DEVICE;
D O I
10.5114/aic.2018.74359
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Transcatheter aortic valve implantation (TAVI) improves prognosis in patients disqualified from surgical valve replacement. Calcifications of the aortic complex can lead to deformation of the prosthesis, resulting in paravalvular leaks (PVL). Aim: To evaluate the predictive value of quantitative estimation of volume/weight and geometric distribution of calcifications in multislice computed tomography, for the development of PVL. Material and methods: This was a retrospective, case-control study on patients with a CoreValve aortic prosthesis. The study group consisted of 20 patients with confirmed significant PVL after TAVI. The control group consisted of 20 patients without significant PVL, matched according to valve type and clinical characteristics. The size spatial distribution and shape of calcifications were measured. Results: The average age of patients was 79.9 years (60% women). Cases and controls did not differ in their clinical characteristics. The size of the aortic annulus was significantly larger in cases vs. controls (23.4 +/- 1.6 vs. 22 +/- 1.4 mm, p = 0.01). Volume, area and curvature of calcifications were greater in cases vs controls (1.09 +/- 0.56 vs. 0.59 +/- 0.41 cm(3), p = 0.011; 15.26 +/- 5.46 vs. 9.50 +/- 5.29 cm(2), p = 0.008; 1.76 +/- 0.07 vs. 1.68 +/- 0.13 cm(3), p = 0.037). In multivariate analysis, adjusted for aortic annulus size, the area of aortic valve calcifications independently predicted paravalvular regurgitation (OR = 1.41, 95% CI: 0.09-1.92, p < 0.009). Conclusions: Morphometric analysis of aortic valve calcifications predicted the risk of paravalvular leak following TAVI irrespectively of patients' clinical characteristics.
引用
收藏
页码:85 / 89
页数:5
相关论文
共 50 条
  • [1] Computed tomography assessment of the aortic root morphology in predicting the development of paravalvular leak following transcatheter aortic valve implantation
    Nieznanska, Malgorzata
    Zatorska, Karina
    Stoklosa, Patrycjusz
    Marzec, Karolina
    Misztal-Ogonowska, Malgorzata
    Kowalik, Ilona
    Dabrowski, Maciej
    Chmielak, Zbigniew
    Witkowski, Adam
    Hryniewiecki, Tomasz
    Michalowska, Ilona
    POLISH ARCHIVES OF INTERNAL MEDICINE-POLSKIE ARCHIWUM MEDYCYNY WEWNETRZNEJ, 2021, 131 (10):
  • [2] Role of Multislice Computed Tomography in Transcatheter Aortic Valve Replacement
    Wood, David A.
    Tops, Laurens F.
    Mayo, John R.
    Pasupati, Sanjeevan
    Schalij, Martin J.
    Humphries, Karin
    Lee, May
    Al Ali, Abdullah
    Munt, Brad
    Moss, Rob
    Thompson, Christopher R.
    Bax, Jeroen J.
    Webb, John G.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (09) : 1295 - 1301
  • [3] Quantitative assessment of paravalvular regurgitation following transcatheter aortic valve replacement
    Crouch, Gareth
    Tully, Phillip J.
    Bennetts, Jayme
    Sinhal, Ajay
    Bradbrook, Craig
    Penhall, Amy L.
    De Pasquale, Carmine G.
    Baker, Robert A.
    Selvanayagam, Joseph B.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
  • [4] "Valve-in-Valve" for the Treatment of Paravalvular Leaks Following Transcatheter Aortic Valve Implantation
    Rodes-Cabau, Josep
    Dumont, Eric
    Doyle, Daniel
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 74 (07) : 1116 - 1119
  • [5] Prevention and management of paravalvular leaks post transcatheter aortic valve implantation
    Bianchi, Renatomaria
    Bigazzi, Maurizio Cappelli
    Salerno, Gemma
    Tartaglione, Donato
    Ciccarelli, Giovanni
    Golino, Paolo
    GIORNALE ITALIANO DI CARDIOLOGIA, 2020, 21 (11) : 17S - 25S
  • [6] Risk factors for paravalvular leak after transcatheter aortic valve replacement
    Pollari, Francesco
    Dell'Aquila, Angelo Maria
    Soehn, Claudius
    Marianowicz, Jill
    Wiehofsky, Pia
    Schwab, Johannes
    Pauschinger, Matthias
    Hitzl, Wolfgang
    Fischlein, Theodor
    Pfeiffer, Steffen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (04) : 1406 - +
  • [7] Computed Tomography for Planning Transcatheter Aortic Valve Replacement
    Apfaltrer, Paul
    Henzler, Thomas
    Blanke, Phillip
    Krazinski, Aleksander W.
    Silverman, Justin R.
    Schoepf, U. Joseph
    JOURNAL OF THORACIC IMAGING, 2013, 28 (04) : 231 - 239
  • [8] Aortic valve calcification and myocardial fibrosis determine outcome following transcatheter aortic valve replacement
    Evertz, Ruben
    Hub, Sebastian
    Beuthner, Bo Eric
    Backhaus, Soeren J.
    Lange, Torben
    Schulz, Alexander
    Toischer, Karl
    Seidler, Tim
    von Haehling, Stephan
    Puls, Miriam
    Kowallick, Johannes T.
    Zeisberg, Elisabeth M.
    Hasenfuss, Gerd
    Schuster, Andreas
    ESC HEART FAILURE, 2023, 10 (04): : 2307 - 2318
  • [9] Aortic valve calcification as a predictor of location and severity of paravalvular regurgitation after transcatheter aortic valve implantation
    Koh, Ezra Y.
    Lam, Kayan Y.
    Bindraban, Navin R.
    Cocchieri, Riccardo
    Planken, R. Nils
    Koch, Karel T.
    Baan, Jan, Jr.
    de Mol, Bas A.
    Marquering, Henk A.
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2015, 20 (03) : 345 - 350
  • [10] Temporal Change in Paravalvular Leakage after Transcatheter Aortic Valve Replacement with a Self-Expanding Valve: Impact of Aortic Valve Calcification
    Ko, Tsung-Yu
    Kao, Hsien-Li
    Chen, Yi-Chang
    Lin, Lung-Chun
    Liu, Ying-Ju
    Yeh, Chih-Fan
    Huang, Ching-Chang
    Chen, Ying-Hsien
    Chen, Yih-Sharng
    Lin, Mao-Shin
    ACTA CARDIOLOGICA SINICA, 2020, 36 (02) : 140 - 147