Discharge probability measurement of a Triple GEM detector irradiated with neutrons

被引:23
作者
Croci, G. [1 ]
Alfonsi, M. [1 ]
Ropelewski, L. [1 ]
Tsipolitis, G. [2 ]
Fanourakis, G. [3 ]
Ntomari, E. [3 ]
Karakostas, K. [2 ]
机构
[1] CERN, Geneva, Switzerland
[2] Natl Tech Univ Athens, GR-10682 Athens, Greece
[3] Nat Cent Sci Res Demokritos, Athens, Greece
关键词
Triple GEM; Neutrons; Discharge probability;
D O I
10.1016/j.nima.2013.02.014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Neutron GEM-based detectors represent a new frontier of diagnostic devices in neutron-linked physics applications such as detectors for fusion experiments (Croci et al., 2012 [1]) and spallation sources (Murtas et al., 2012 [2]). Besides, detectors installed in HEP experiments (like LHC at CERN) are dip in a high flux neutron field. For example, the TOTEM T2 GEM telescope (Bagliesi et al., 2010 [3]) at LHC is currently installed very close to the beam pipe where a high intensity (> 10(4) n cm(-2) s(-1)) neutron background is present. In order to assess the capability (particularly related to discharge probability) of working in intense neutrons environment, a 10 x 10 cm(2) Triple GEM detector has been tested using a high flux (10(5) n cm(-2) s(-1)) neutron beam. The neutron-induced discharge probability P-Disch was measured to be 1.37 x 10(-7) at an effective gain G = 5 x 10(4). In addition, the different types of neutron interactions within the detector were fully explained through a GEANT4 simulation. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:108 / 112
页数:5
相关论文
共 7 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]   Construction, test and commissioning of the triple-gem tracking detector for compass [J].
Altunbas, C ;
Capéans, M ;
Dehmelt, K ;
Ehlers, J ;
Friedrich, J ;
Konorov, I ;
Gandi, A ;
Kappler, S ;
Ketzer, B ;
De Oliveira, R ;
Paul, S ;
Placci, A ;
Ropelewski, L ;
Sauli, F ;
Simon, F ;
van Stenis, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 490 (1-2) :177-203
[3]   Discharge studies and prevention in the gas electron multiplier (GEM) [J].
Bachmann, S ;
Bressan, A ;
Capeáns, M ;
Deutel, M ;
Kappler, S ;
Ketzer, B ;
Polouektov, A ;
Ropelewski, L ;
Sauli, F ;
Schulte, E ;
Shekhtman, L ;
Sokolov, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3) :294-308
[4]   The TOTEM T2 telescope based on triple-GEM chambers [J].
Bagliesi, M. G. ;
Berretti, M. ;
Brucken, E. ;
Cecchi, R. ;
David, E. ;
Garcia, F. ;
Greco, V. ;
Heino, J. ;
Hilden, T. ;
Kurvinen, K. ;
Lauhakangas, R. ;
Lami, S. ;
Latino, G. ;
Magazzu, G. ;
Oliveri, E. ;
Pedreschi, E. ;
Ropelewski, L. ;
Scribano, A. ;
Spinella, F. ;
Turini, N. ;
Van Stenis, M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3) :134-137
[5]   Two-dimensional readout of GEM detectors [J].
Bressan, A ;
De Oliveira, R ;
Gandi, A ;
Labbé, JC ;
Ropelewski, L ;
Sauli, F ;
Mörmann, D ;
Müller, T ;
Simonis, HJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 425 (1-2) :254-261
[6]   nGEM neutron diagnostic concept for high power deuterium beams [J].
Croci, G. ;
Rebai, M. ;
Claps, G. ;
Cavenago, M. ;
Dalla Palma, M. ;
Gervasini, G. ;
Grosso, G. ;
Murtas, F. ;
Pasqualotto, R. ;
Cippo, E. Perelli ;
Tardocchi, M. ;
Tollin, M. ;
Gorini, G. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[7]   Triple GEM gas detectors as real time fast neutron beam monitors for spallation neutron sources [J].
Murtas, F. ;
Croci, G. ;
Pietropaolo, A. ;
Claps, G. ;
Frost, C. D. ;
Cippo, E. Perelli ;
Raspino, D. ;
Rebai, M. ;
Rhodes, N. J. ;
Schooneveld, E. M. ;
Tardocchi, M. ;
Gorini, G. .
JOURNAL OF INSTRUMENTATION, 2012, 7